Length: 90, 230 mm
Number of holes: 3, 12 unit
TRUE LOCK Proximal Humerus Anatomic Plates are indicated for fractures and fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly for patients with osteopenic bone. Proximal ...
Truemed Medical
Length: 95, 110, 125, 140 mm
Number of holes: 6, 8, 10, 12 unit
... (%5). The clavicle is the first ossified bone and the ossification center closes last. It is in the form of “S” and convex to the medial anterior and concave to the lateral anterior. Anatomical plate; ...
Truemed Medical
Length: 60, 80, 100, 120 mm
Number of holes: 6, 8, 10, 12 unit
... all fractures and approximately one third of humerus fractures Anatomical plate; right & left 4 hole option between 6-12 TRUE LOCK Distal Humerus Lateral Anatomic Plates are made of Ti6Al4V ELI ...
Truemed Medical
Shortening Healing Time Less Hospital Stays Faster Sternum Recovery Time Alleviate Patient Nociception and Other Syndromes Lower Risk of Causing Sternum Dehiscence and Facture Reliable Rigid Fixation High-end Titanium ...
S33 Spine Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery and it offers a wide range of plates and screw sizes. Low profile (2,0 mm) pre-bended plates Single ...
Number of holes: 6 unit
Can be used for one or more segments Quite thin plate No height on the plate
... The double bended mini plates fit the anatomy of the dorsally elevated lamina The plates are low profile and they prevent tissue irritation Provides secure grasp of the implant Intraoperative conformity ...
Anterior Cervical Plate System PROCTOPUS™ Prodorth Cervical Plate System is designed to meet the clinical expectations of anterior cervical surgery and it offers a wide range of plates ...
... wide selection of plates to accommodate the variety of fractures encountered during routine surgeries. The plates are available in two profile thicknesses (0.8 mm and 1.2 mm) and different anatomically ...
AGOMED Medizin-Technik
Thickness: 1.5 mm
... multidirectional system with various plates that have been anatomically adapted to the distal radius & the distal ulna PLATE FEATURES • Rounded edges & a smooth surface for soft tissue protection • ...
AGOMED Medizin-Technik
... -contoured plates is designed for use in the radial head’s “safe zone”. Plates have two proximal rows of screws for better support of the head and two plate bars in the shaft region for ...
AGOMED Medizin-Technik
Length: 65, 25 mm
Number of holes: 8, 4, 6 unit
SOFEMED efficient, and mechanical tested systems for spine surgery according to European medical devices testing center.
SOFEMED International
Number of holes: 2, 14 unit
... and mechanical tested systems for spine surgery according to European medical devices testing center. Posterior cervical plate for screw Ø3,5 and 4 mm
SOFEMED International
Length: 24, 134 mm
... efficient, and mechanical tested systems for spine surgery according to European medical devices testing center. Cervical H-plate for screw Ø2,7 and 3,5 mm
SOFEMED International
Thickness: 6 mm
Hole diameter: 5 mm
... ® Locking Periprosthetic Support Cable-Plate Systems are compatible with Ortholox® UHMWPE Cerclage Band System thanks to its Plate-Band Button Implant and in combination, they assist in keeping the displaced ...
Length: 127, 367 mm
Thickness: 5 mm
Number of holes: 4, 16 unit
... periprosthetic locking cortex screws. The structure of the holes in the shaft part is also compatible with Plate-Band Button Implant and Locking Attachment Plate connection screws. They can be used for ...
Length: 152.5, 110, 134, 170, 201.5 mm
Thickness: 2.5, 1.8 mm
Hole diameter: 1.2, 1.9 mm
Eonex tibia plates hâve a robust, anatomically-contoured design with idéal accommodation for the anatomyand pathology of complex tibia fractures. The locking holes in the Eonex tibia plates allow for ...
Eonex Medical
Length: 60.2, 78.2, 114.8, 101.8, 51.2 mm
Thickness: 2.2, 2 mm
Hole diameter: 1.4, 1.6 mm
... volar distal radius plates accepts variable angle locking, non-lockingand compression screws in diameters 2.0 and 2.4 in distal part of volar plate and 2.7mm to 3.5mm in proximal part of volar plate. VOLAR ...
Eonex Medical
The Eonex Proximal Humérus Plate Construct consists of a high-strength stabilization plate designed to best accommodate the anatomy and pathology of the proximal humérus. The anatomie curvature of the ...
Eonex Medical
Length: 109, 91, 106, 88 mm
Thickness: 3.5 mm
Number of holes: 6, 4, 8, 10 unit
... locking or non-locking screw (except compression hole). In particular the anatomical plate design as well as the pre-angled plate holes of the lateral plate version provide an optimal ...
I.T.S.
Length: 48, 54, 58, 64 mm
Hole diameter: 10 mm
Number of holes: 5, 7, 8, 6 unit
... Locking Anatomical plate design Short plate version located directly under the subtalar joint (small and large) Long plate version located directly under the subtalar joint with an ...
I.T.S.
Length: 69, 60 mm
Thickness: 1.5 mm
The Locking Calcaneus Plate is a proven osteosynthesis system for various calcaneus fractures. The special feature of this implant is the free choice of screw placement. The user is able to set any desired screw in any ...
I.T.S.
... Anterior Cervical Plate I, 4 Holes, 19mm Anterior Cervical Plate I, 4 Holes, 21mm Anterior Cervical Plate I, 4 Holes, 23mm Anterior Cervical Plate I, 4 Holes, 25mm Anterior ...
Boneunion Medical
Length: 34 mm
Thickness: 1.5 mm
... Universal Instrument Set Series: Foot and Ankle System Part: N/A Bone: Ankle Description FA L-Locking Plate, left, 34mm FA L-Locking Plate, right, 34mm Additional information Direction Left, ...
Boneunion Medical
Length: 36, 42, 48, 54, 61 mm
Thickness: 1.6 mm
Number of holes: 4, 5, 6, 7, 8 unit
... Part: N/A Bone: Ankle Description FA Straight Fusion Locking Plate, 4 Holes, 36mm Length FA Straight Fusion Locking Plate, 5 Holes, 42mm Length FA Straight Fusion Locking Plate, ...
Boneunion Medical
... range of titanium plates are available to fit the anatomical structures and individual clinical requirements. Titanium Plates Reduced bar thickness at osteotomy for Fast Emergency Access Angular ...
... and osteotomies but also of the degree of bending of the plates. Easy handling – can be used immediately Fewer bending operations Basal insertion Smaller contact surface with the bone
Number of holes: 8 unit
... the tibia. • Post-Contoured plate anatomically designed to wrap around the bone • Locking screw and cortical screw options • Double-threaded screw design for quick insertion • Wedge block for firm ...
Number of holes: 9 unit
• V-shape for visualization / avoid tendon damage • Chamfered plate contour to minimize risk of tendon and soft issue damage. • Distal window for fracture visualization • Titanium alloy(Ti6Al4ELI) • Anodizing finish • ...
Length: 67, 99, 131, 163, 277 mm
Thickness: 3.4 mm
Hole diameter: 4, 4.5 mm
... fractures in long bones, for small fragments in the upper and lower limbs. The rigid connection between the locking screws and the plate allows better clinical results in the methaphyseal fracture, comminute ...
Ortobio
Length: 121.5, 181.5, 261.5, 321.5, 401.5 mm
Thickness: 5.2 mm
Number of holes: 7, 9, 12, 15, 20 unit
... upper limbs. The rigid connection between the locking screws and the plate allows better clinical results in the methaphyseal fracture, comminute fractures and in osteoporotic bones from different regions. It ...
Ortobio
Length: 189, 227, 246, 113, 151 mm
Thickness: 2 mm
Hole diameter: 5.5 mm
... fractures in long bones, for small fragments in the upper and lower limbs. The rigid connection between the locking screws and the plate allows better clinical results in the methaphyseal fracture, comminute ...
Ortobio
... anterior cervical plate has become widely accepted when anterior spinal fusion is performed to stabilize the spine for tumor, trauma, deformity, degenerative disc disease and other forms of cervical instability. The addition ...
... compared to our standard Universal Mandible reconstruction plates. Proprietary software to select specific plate design features such as profile height, screw hole location, and 3D run of the plate. Allows ...
Stryker
... and poor bone to promote bone union. The system is designed to offer surgeons simplicity and ease of use when approaching rib fracture repair. Plates are engineered to match the natural ...
Zimmer Biomet
... degree cone 1.4mm K-wire holes for distal plate positioning Slotted 1.4mm K-wire hole or slotted screw hole to allow for proximal/distal plate adjustments 1.4mm K-wire hole to enable centering of the ...
Smith & Nephew
MatrixMANDIBLE™ Preformed Reconstruction Plates are pre-shaped internal fixation plates for mandible reconstruction procedures and are compatible with MatrixMANDIBLE™ Screws and Instruments. Feature: Preformed ...
Depuy Synthes
Anatomical contoured plate design: Asymmetrical design with left and right specific options Straight edge lines up with bicipital groove for easier plate positioning Sits 1.5cm below Greater Tuberosity ...
A fracture may malunite in the healing process resulting in bone deformity and loss of function. Our patient specific approach improves the accuracy of corrective surgery by providing patient-specific guides and implants. ...
... confirmations of locking mechanism provide confidence in preventing screw blackout Self-drilling/self-tapping fixed and variable angle bone screw configurations provide intra-operative flexibility for surgeon preferences ...
Life Spine
... scaffold to accurately position the greater and lesser tuberosity. Fracture Plate The Equinoxe Fracture Plate is redefining anatomic fracture reconstruction. The locking plate ...
Length: 43, 188 mm
Number of holes: 2, 13 unit
... system is composed of seven plate families designed specifically for the treatment of ankle fractures. The indication-specific plates address fracture patterns of the medial, lateral, and posterior ...
Acumed
Distal Fibular Locking Plate - Locking or compression screw hole provides more clinical options. Thinned distal plate profile to preserve the thin soft tissue envelope of the distal fibula.
Double Medical Technology
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining