{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
cemented acetabular prosthesis
cemented acetabular prosthesis
SEM IV

Characteristics Cemented PE cup Notched collar For 22.2mm and 28mm femoral heads

cemented acetabular prosthesis
cemented acetabular prosthesis
GALILEA

Characteristics Dual mobility cup Cemented Horizontal and vertical grooves Collar for cement pressurization

cemented acetabular prosthesis
cemented acetabular prosthesis
TREGOR

Characteristics Press-fit dual-mobility cup Cemented with a cement pressurization collar

cemented acetabular prosthesis
cemented acetabular prosthesis
Janus

Biarticular Cup – Reduced risk of dislocation – Reduced load distribution on the natural cotyle – Less likelihood of seizure – Enhanced radiography acceptability – Bicentric When head and mobile cotyle have different centers of rotation ...

cemented acetabular prosthesis
cemented acetabular prosthesis
Muller

The Standard Muller cup is characterized by a depth ranging from 27mm to 37mm depending on the size. The 10° wall Muller cup provides greater coupling surface thanks to the 10 °inclination of the spherical cap. Sizes from 44 to 60 mm, ...

revision acetabular prosthesis / cemented
revision acetabular prosthesis

... accordance to the specification ISO 5832-9. – Constrained Cemented Cup – Double Constrained Cemented Cup

cemented acetabular prosthesis
cemented acetabular prosthesis
MÜLLER ANTILUXANTE

... compression molding process offers high strength characteristics, minimizing wear conditions. The MÜLLER is a cemented acetabular prosthesis.

cemented acetabular prosthesis
cemented acetabular prosthesis
Gyptis®

From 44 to 62 mm UHMWPE ISO 5834-2 + Stainless steel ISO 5832-1 Cup to be cemented Anti luxation system with a 10° rim

cemented acetabular prosthesis
cemented acetabular prosthesis
Delta

- Acetabular Cemented Component - With flange polymetylacrilate spacers to maintain an homogeneous bone cement layer - Available in 10 different diameters - Law be used with three different femoral head diameters.

cemented acetabular prosthesis
cemented acetabular prosthesis
MOBILITY®

12 sizes (from 44 to 66 mm). Complete inside polish surface and glazing outside surface. External grooves to ensure a uniform cement mantle. Stainless steel (ISO 5832-1).

revision acetabular prosthesis / cemented
revision acetabular prosthesis
Trabecular Metal™

Trabecular Metal™ Acetabular Revision System 1000x1000_insetimage_Hips_TMARS The Zimmer Biomet Trabecular Metal Acetabular Revision System (TMARS) combines clinically proven Trabecular Metal Technology1–3 ...

cemented acetabular prosthesis
cemented acetabular prosthesis
ALTRX™ ALTRALINKED™

Division: Hip Reconstruction Category: Polyethylene Liners and Cemented Cups ALTRX Poly is an ultra-low-wear polyethylene manufactured using a unique ALTRALINK® material enhancement process to allow a balance between ...

See the other products
Depuy Synthes
cemented acetabular prosthesis
cemented acetabular prosthesis
Versacem

The Versacem is the cemented acetabular shell for double mobility which: can assure the primary stability due to the cement, even with poor bone quality; can assure high stability thanks to the ...

See the other products
Medacta
cemented acetabular prosthesis
cemented acetabular prosthesis
SATURNE®

SATURNE® CEMENTED HIP - ACETABULAR COMPONENTS - PRIMARY Line of dual mobility cups suitable for primary and reconstruction total hip arthroplasty Available in cemented, cementless and ...

See the other products
Amplitude Surgical
revision acetabular prosthesis / cemented
revision acetabular prosthesis

Acetabular plates & Cemented cups Lima Corporate’s cemented cup is manufactured in UHMWPE and available in several sizes and two different versions. The standard version is completely ...

cemented acetabular prosthesis
cemented acetabular prosthesis
ATHELIA II

Highly polished surface with longitudinal and vertical grooves to ensure the implant's stability with the cement. Cylindrical anti-dislocation rim. Hemispheric with 15° progressive outer chamfer. Cup ...

See the other products
EUROS
revision acetabular prosthesis / cemented
revision acetabular prosthesis
M

Acetabular component Type “Müller” - Cemented All Poly Cemented all poly acetabular components type .Müller” have proven over the years to provide lasting services. This ...

See the other products
Biotech Medical
cemented acetabular prosthesis
cemented acetabular prosthesis
type 02/II

CHARACTERISTICS OF THE IMPLANTMaterial: Crosslinked UHWMPE (ISO 5834-2)Significant improvement in abrasion resistance.Use of centralizersCentralizers ensure an even 2mm layer of bone cement.Stamped-on centralizersThere is no danger of ...

See the other products
Beznoska
cemented acetabular prosthesis
cemented acetabular prosthesis
Constrained

Prevent recurrent dislocation in elderly patients, subsequent to muscle loss. THR in elderly patients with a high risk of dislocation.

See the other products
Groupe Lépine
cemented acetabular prosthesis
cemented acetabular prosthesis
Novae® Stick/K

The Novae® Stick is a cemented version which can be used with or without the K reinforcement cross. It has no peripheral band. The K cross incorporates PMMA spacers to prevent bottoming out and ensure an adequate cement mantle.

See the other products
SERF
cemented acetabular prosthesis
cemented acetabular prosthesis

cemented polyetethelene acetabular cupThe patented design of stable liner and shell-locking, which has excellentfunction for anti-escaping and anti-prizing, achieved better effect of implan-tation and ...

cemented acetabular prosthesis
cemented acetabular prosthesis

cemented acetabular prosthesis
cemented acetabular prosthesis
HIP'N GO

The cementless dual mobility acetabular cup ranges (either press-fit or tripod) exist in 10 sizes, ranging in diameter from 46 mm to 64 mm in 2 mm increments. The inserts are available with an internal diameter of 22.2 ...

revision acetabular prosthesis / cemented
revision acetabular prosthesis
C

The "C" is a dual mobility cup designed for cemented use. The cup is associated with a acetabular protrusio cross-shell meant to rebuild the acetabulum in revision cases and restore the physiological ...

See the other products
EVOLUTIS
cemented acetabular prosthesis
cemented acetabular prosthesis

In 1978, Elite identified polyethylene particles as the prime reason for disastrous sub-interface osteolysis. According to a technical paper, considering the mechanical point of view, the HDPE's radiation crosslinking shows a distinctive ...

cemented acetabular prosthesis
cemented acetabular prosthesis
MERCURY®

... available in a cemented version, a press-fit version and reinforced primary anchorage version. Details Medialisation of the joint’s centre of rotation facilitates recentring of the insert. The outer surface macrogeometry ...

See the other products
C2F Implants
revision acetabular prosthesis / cemented
revision acetabular prosthesis
Bencox® Bipolar Cup

Optimal Fit ­A large array of component allows precise patient matching for optimal patient fit ­Outer diameters from 38 to 60mm allow the surgeon to meet the unique challenges posed in revision and extended situation ­The ...

cemented acetabular prosthesis
cemented acetabular prosthesis

Cemented acetabular cup is intended for restoration of function and form of the natural joint, and for rehabilitation of patients with traumas and diseases of musculoskeletal system.

cemented acetabular prosthesis
cemented acetabular prosthesis
Screw Cup SC®

Screw Cup SC® Acetabular Cup System Cementless screw cup system with polyethylene or ceramic inserts Thin thread flanks and large pitches give more solid bone lamellae. Especially the combination of large thread ...