Size - Femoral Canal Broach - Changeable Femoral Head Ф40/28 - 40 - Ф28 Ф42/28 - 42 - Ф28 Ф44/28 ...
Screw Cup SC® Acetabular Cup System Cementless screw cup system with polyethylene or ceramic inserts Thin thread flanks and large pitches give more solid bone lamellae. Especially the combination of large thread distances ...
Acetabular cup diameter: 44 mm - 56 mm
Femoral head diameter: 22 mm - 28 mm
can assure the primary stability due to the cement, even with poor bone quality;can assure high stability thanks to the double mobility liner;is made of stainless steel and its double mobility liner is available in standard UHMWPE or ...
Acetabular cup diameter: 40 mm - 60 mm
Femoral head diameter: 22 mm - 32 mm
The Apricot Cemented Cup is a well proven implant, used since 1989. The cemented acetabular cup has a flat rim and it is circumferentially ridged and radially grooved to improve the cement ...
Acetabular cup diameter: 22.2 mm - 28 mm
Femoral head diameter: 42 mm - 62 mm
The Native cemented cup is based on the well known concept of the Sir John Charnley cup, one of the most used on the market with more than one million cups implanted worldwide. The Native cup is available in both standard ...
• Cross linked polyethylene (XLPE) material. • Double locking mechanism. • Liner ears prevent rotation.
Femoral stem length: 13.5, 7.5 mm
Acetabular cup diameter: 42 mm - 62 mm
Femoral head diameter: 22 mm - 28 mm
Acetabular Cup (Cemented) (10°) used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Femoral Stem Dual Coated (Cementless) Femoral Stem (Cemented) Calcar ...
Acetabular cup diameter: 22.2 mm - 28 mm
... available in a dysplasia version INITIALE® Revision: cemented revision femoral stem available in various lengths Reconstruction cage: cemented acetabular reconstruction cage
Acetabular cup diameter: 38 mm - 50 mm
Femoral head diameter: 22 mm - 28 mm
Enhanced 60' ROM resists the impingement to the UHMWPE locking ring. Proportional Eccentricity Multipolarity is achieved via multiple offsets within the system as cup sizes increase, the amount of eccentricity increases. Provides ...
Acetabular cup diameter: 44 mm - 58 mm
... stock and guarantees uniform load distribution to the bone thanks to the close contact with the acetabular bone of less than 0.5 mm. These are cemented cups, meaning that the convex external surface ...
Acetabular cup diameter: 41 mm - 63 mm
... disease transmission Creates a monolithic construct without concerns for micromotion by using cemented interfaces6 Designed to conserve host bone while implant size, position, and orientation are ...
Acetabular cup diameter: 24 mm - 36 mm
... shape of the acetabular cups helps to prevent loosening. Radial notches on the surface create a high degree of cement contact and allow air to escape when the implant is pressed into the cement bed.Approximately ...
Waldemar Link
... binding strength between the prosthesis and cement; 2.Imported ultra-high molecular weight polyethylene material with strong anti-wear ability; 3.The acetabulum indicating ring makes it easier to observe the prosthesis ...
... risk of instability, adapts the implant to the bone rather than the bone to the implant (during surgery, there is no need to shape the bone in order to adapt it tothe implant or use bone ...
Acetabular cup diameter: 44 mm - 66 mm
The MOBILITY® prostheses range consists of acetabular cups with fixed or double mobility liners designed to replace the natural hip joint on first intention or during revision surgery. Stainless steel ISO 5832-1 External ...
Femoral head diameter: 28 mm - 32 mm
... position of cup with help of x-ray. At the lower basis of the insert there is a hemispherical indent made for setting-up the prosthesis head. Metal-polumer friction pair Metallic heads combine good mechanical parameters ...
Acetabular cup diameter: 45 mm - 62 mm
The cup is associated with a acetabular protrusio cross-shell meant to rebuild the acetabulum in revision cases and restore the physiological hip joint rotation center.
EVOLUTIS
Acetabular cup diameter: 28 mm - 64 mm
... cups are designed to be cemented, which is why their convex outer surface has a special grooved design, aimed at improving the primary fixation of the cup itself. Primary fixation takes place between the cup and the ...
Cup - Crosslinked UHMWPE (ISO 5834-2) Centralizers - PMMA
... rehabilitation after severe Paprosky type IIIA and IIIB acetabular destruction, by cementing the cup in a fixed acetabular cage. Can be used alone (without a fixed acetabular cage), ...
SERF
From 44 to 62 mm UHMWPE ISO 5834-2 + Stainless steel ISO 5832-1 Cup to be cemented Anti luxation system with a 10° rim
Acetabular cup diameter: 22.2 mm - 28 mm
... retaining effect. The metal meridian and equatorial radiological markings make it possible to check the correct position of the implant radiologically and to control PE wear postoperatively.
C2F Implants
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining