Femoral stem length: 120, 130, 140, 150, 190 mm
Size Length(mm) Femoral Canal Reamer Femoral canal Broach Centralizer Restrictor 0 - 120 - 1(7.5) - 1 - 0 - >Ф11 1 - 130 - 2.5(9.75) ...
Trilliance® Hip Stem System Triple tapered. Polished. The philosophy of the Trilliance® triple tapered polished hip stem is a design evolution of this type of cemented hip stem ...
CCD angle: 130, 125 °
... PARADOX" A stem matching the femoral canal is implanted line-to-line, resulting in a thin cement mantle. The French technique is intended to maximize the stem size within the medullary ...
Medacta
Femoral stem offset: 35.5, 37.5, 44, 50 mm
CCD angle: 125 °
... mm shortened X-acta stem was designed to facilitate stem implantation through the AMIS approach and reduce bone removal. SUCCESSFUL CLINICAL HISTORY The collarless, double-tapered, polished design ...
Medacta
CCD angle: 135, 127 °
... broaching and stem insertion when utilising the AMIS approach without compromising implant stability. BONE PRESERVING, AMIS FRIENDLY: First stem specifically designed for AMIS Reduced bone removal ...
Medacta
Femoral stem length: 50, 44, 37.5, 35.5 mm
CCD angle: 125 °
... insertion level of the stem compared to the broach, for adequate leg length reproduction. Rounded shoulder: Ease of insertion without greater-trochanter disruption PMMA distal centralizer allows for subsidence and ...
Amplitude Surgical
Femoral stem length: 98, 134 mm
CCD angle: 137, 129, 140 °
... connection. Threaded hole at bottom of cavity for extraction tool. Impaction point at top of stem is offset to ensure impaction is in line with shaft axis. Stem–neck combination: titanium–titanium. Line ...
Amplitude Surgical
CCD angle: 137 °
... on top of stem. Threaded hole used for extraction. Femur stem option within a product line based on the same concept: - GENERIC®: cemented femoral ...
Amplitude Surgical
... hip replacement in skeletally mature individuals. The system consists of monolithic cemented and press-fit femoral stems, modular CoCr and BIOLOX® delta femoral heads ...
CCD angle: 135, 126 °
• The range of stems allows the implant to be matched to all bone sizes. • Taper 12/14, completely conical form.
Femoral stem length: 12, 7 mm
Acetabular cup diameter: 28 mm - 28 mm
Femoral head diameter: 42 mm - 62 mm
Femoral Stem (Cemented) used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Bipolar Head Acetabular ...
Femoral stem length: 200, 250 mm
... on decades of clinical history. Stems are M30NW stainless steel with a mirror polished finish designed for cemented fixation. A mirror polished finish is a proven design and is aimed at achieving long ...
C-STEM™ AMT has a comprehensive size range and can be used with both metal and ceramic heads as either a hybrid or fully cemented Total Hip Replacement (THR). About This System The C-STEM™ ...
Femoral stem length: 8, 18 mm
CCD angle: 132 °
... needs, all with one standard set of instrumentation. The system offers cemented stems with the 450 and 460 series, porous stems with the 470 and 480 series and a press-fit 440 series ...
Femoral stem length: 150 mm
Femoral stem offset: 41 mm
CCD angle: 126 °
Cost-efficient, lean system Stem system successfully used for decades Cemented implant for rapid postoperative mobilization Rapid postoperative mobilization The cemented placement ...
1. Based on the classic theory of EXETER polishing design; 2. Highly polished surface minimizes the wear between the prosthesis and cement; 3. Double cone collar-free design: Allows the prosthesis to sink slightly in the cement sheath ...
Femoral head diameter: 22.2 mm - 28 mm
CCD angle: 130 °
... alumina. DESCRIPTION Standard range of metaphyseal-filling stems supplemented by a series of dysplastic stems and long stems intended for revisions. Rectangular section of the ...
CCD angle: 135 °
... wear resistance: cementes stem is made of REX steel, cementless is of titanium. Cementless mircoporotic surface can be titanium plasma or Hydroxi-apatite as well. With the wide range of stems, resps functioning ...
Sanatmetal
Universal Hip Implants Size - #3L - #4S Size #4 - #5 - #6 #7 - #8 - #9 #10 - #11 - #12
... old fracture of the femoral neck, pain from destruction of the femoral head or acetabulum, resulting in impairment of joint function; 2. Patients with avascular necrosis of the femoral ...
CCD angle: 135 °
... conical distal tip: Prevents diaphyseal locking and provides a construction with distal flexibility so as to not compromise the cemented fixation.
Surgival
CCD angle: 135 °
CINEOS® prostheses consist of femoral stems designed for the replacement of the natural hip joint during first intention or during revision surgery. 10 sizes 12/14 taper Without collar Stainless ...
X-NOV Medical Technology
... cracking Tapered stem shape and implant collar provide stability against subsidence Uniform cement mantle is present over the entire length of the implant Flat hexagonal stem profile provides a high ...
Femoral stem length: 136, 186 mm
... intramedullary blood supply. Grooves Cemented femoral stem has fixing grooves on its side surfaces in the proximal part of the stem. Design of cemented ...
Femoral stem length: 300, 120 mm
Femoral stem offset: 35.3, 44 mm
The Alpha shank is highly polished and has a Euro Cone and wedge-shaped rectangular profile, allowing for homogeneous load distribution. – Premium raw material (High Nitrogen Stainless Steel); – Minimal friction with bone cement (Highly ...
... Highly polished surface reduces the shear force of the contact surface between the prosthesis and the bone cement; 4. Allow the stem to sink slightly and fix it twice; Used with the third-generation bone cement technology, ...
Beijing Chunli Technology Development
Femoral stem length: 6.25, 20 mm
Smooth structured, lateralized and medialized self-locking stem. Materials Made of high-nitrogen stainless steel compliant with ISO 5832/9 standards. Thanks to the high nitrogen content and the final post-casting ...
... caused by the friction between stem neck and UHMWPE component Standard Offsets Reduced proportionate Neck Geometry to increase Range of motion Design Cemented stem BC is made of Co-Cr- ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining