- Secondary care >
- Orthopedic surgery >
- Cementless hip prosthesis
Cementless hip prostheses
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... State of Arthroplasty The Metha Short Hip Stem prosthesis represents a new generation of implants for hip endoprosthesis. It combines two advantages: minimal stem size and a circumferential coating. ...
Aesculap®
... straight tapered and fully surface coated cementless hip stem. The implant range is available for standard and lateralized offset stems (+6 mm). The TrendHip® triple tapered shape additionally supports ...
Aesculap®
... TRJ® Hip stem – Trochanter retaining joint replacement The TRJ® hip prosthesis stem is implanted withoutcement. The stem design is based on many years of experience with a conical diaphyseal anchorage ...
Aesculap®
Femoral stem offset: 36, 54 mm
... The ACTIS™ Hip Stem’s patented1 design offers proven implant stability2, with over 400,000 in clinical use3. The ACTIS Hip Stem is powered by enabling technologies KINCISE™ Surgical Automated System and ...
Depuy Synthes
... range of motion than circular neck designs,* which may reduce the potential risk of dislocation. The ANTHOLOGY AFIT Primary Hip System features a reduced distal cross-section as an option for patients with a narrow femoral canal. Product ...
Smith & Nephew
CCD angle: 135 °
... approaches to total hip arthroplasty. The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, which facilitates the implantation ...
Enovis Surgical
... Biological Hip Prosthesis System The product design is based on human engineering mechanics, human biology and long-term clinical pathology research. It is made of materials recognized in the world's medical field, which ...
... Overview
The total
hip
prosthesis is designed for patients requiring
hip joint replacement due to arthritis, fracture, or other conditions. It provides improved mobility and pain relief.
Features
- Durable
... CANWELL Primary Cementless Femoral Stem Artificial Hip Prosthetics Joint Replacement Total Hip Replacement CE - Category: Hip & Knee - Brand: Canwell Medical - Type: ...
Femoral stem length: 7.5, 13.5 mm
... Femoral Stem Dual Coated ( Cementless) SIZE (mm) 7.5 9 10 11 12 13.5 ...
Zimed Medical
... Calcar Replacement Stem Dual Coated ( Cementless) (CoCrMo Alloy) REF. NO SIZE (mm) 7033-3251 25/9 7033-3252 25/11 7033-3253 25/13 7033-3351 ...
Zimed Medical
Femoral head diameter: 28 mm - 36 mm
... Modular Straight Stem (Sandblasting)
Technical specifications
- Brand: Zimed Medikal
- Category: Revision hip prostheses (hip
Zimed Medical
Femoral stem length: 117.5, 79.5 mm
Femoral stem offset: 41.4, 32.2 mm
... patients. Conserving bone MiniHip is designed to provide the bone preserving benefits of hip resurfacing with the stability of traditional total hip replacement. With MiniHip, typically a mid-neck resection ...
Corin
... to total hip arthroplasty. REDUCED PROXIMAL LATERAL DESIGN The proximal lateral shoulder of the Linear hip is reduced, which facilitates the implantation of the Linear Hip is reduced, which facilitates ...
Trilliant Surgical
Femoral stem length: 114, 81 mm
Femoral stem offset: 50, 29 mm
CCD angle: 128, 133, 124 °
... A contemporary total hip arthroplasty system engineered for reproducibility, performance and efficiency. System Features Titanium Coating Delivers a press-fit into the acetabulum. Polished and Anodized distal segment with distinctive ...
Femoral stem length: 140, 152, 159, 165, 166 mm
Femoral stem offset: 32, 46 mm
CCD angle: 133, 140 °
... body provides rotational stability under dynamic loading Load transferred and transmitted by the interface between the prosthesis and cancellous bone Absolute mechanical stability Cone shaped geometric transition between proximal ...
Femoral stem length: 40, 50, 60, 70 mm
CCD angle: 125, 135 °
... The SMR 100's stem is a modular system designed for hip replacement in particular cases of dysplasia, osteotomies and fractures. The stem features 3 components: proximal, distal and locking screw. INDICATIONS Dysplasia; Osteotomy ...
Gruppo Bioimpianti
Acetabular cup diameter: 42 mm - 62 mm
Femoral head diameter: 28 mm - 36 mm
CCD angle: 135 °
... + Total hip prosthesis, is an operation for replacing a hip joint that has been damaged due to primary or secondary cause and has advanced osteoarthritis. + The total hip prosthesis, ...
Femoral stem length: 130, 144, 150 mm
CCD angle: 135 °
... The stem Austin Moore offers one of the most simple and classic hip hemiarthroplasty solutions market in which the articular cartilage of the acetabulum is respected. The geometry of the section of the rods is of rectangular type with ...
... · Polished neck designed to generated less wear debris secondary to prosthetic impingment. · Double tapper design fits most femoral canal anatomy and preserves more bone stock for revision. · Stepped geometry of the stem surface minimize shear forces ...
Irene Ortho
... A range of total hip implants including 6 versions of femoral stems (standard or laterlized, with or without colar, with or without cement), dual mobility cups and ceramic cups. ...
... TTHR EASY From 10 to 16 135° cervical angle 5°42'30" taper (12/14 mini taper) Collar 4 lengths available (190,240,290 et 340mm). Ti+HA coating Anatomical curve ...
Biotechni
Femoral stem length: 16, 10 mm
Acetabular cup diameter: 46 mm - 66 mm
CCD angle: 127, 132 °
... The Cordera™ Hip System, is an uncemented, primary total hip replacement featuring an industry proven stem design. The implant system can be used with or without a pre-operative CT scan that is used ...
Femoral stem length: 130, 420 mm
Femoral head diameter: 11 mm - 30 mm
... The MRP-TITAN hip revision system is a cementless revision implant for use in the femur. The MRP-TITAN in combination with the modular revision support cup MRS-TITAN Comfort offers a variety of geometric ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group