- Secondary care >
- Orthopedic surgery >
- Femoral head prosthesis
Femoral head prostheses
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Material: UHMWPE : 40/22 ; 48/28-8D ; 42/28-8D ;50/28-8D model : - 44/28-8D - ; 52/28-8D - l5A45 : 46/28-8D ; 54/28-8D
Material : Cobalt Chrome Molybdenum Alloy Spec. : 22/M ; 22/L Offset: 0 ; +3.5 Model H5C00 - 28/S - 28/M - -3.5 - 0 28/L - 28/XL +3.5 - +7 Material : Cobalt Chrome Molybdenum Alloy - Spec. ...
... code) - Bipolar Head D1C50 Size - Ф38/22 - Ф40/22 - Ф42/22 - Ф44/22 - Ф46/22 - Ф48/22 - Ф50/22 - Ф52/22 - Ф54/22 Bipolar Trial - 38 - 40 - 42 - 44 - 46 - 48 - 50 - 52 - 54 Changeable Femoral ...
... Statistic / dynamic fracture resistance 89.3 kN / 72.6 kN IsocerR head 28L / TiAl6V4 12/14 [3] More corrosion resistant taper connection Reduced ion transfer of ceramic heads compared to metal heads ...
Femoral head diameter: 22 mm - 40 mm
Medacta provides a wide and complete range of femoral heads available in different diameters, sizes and materials.
Femoral head diameter: 42 mm - 60 mm
... Arthroplasty, without any damage to the head and the taper, simply removing the Medacta Bipolar Head. BIPOLAR HEAD Outer surface: mirror polished metallic bearing BIPOLAR HEAD ...
Femoral head diameter: 40 mm - 56 mm
... times and lower medical and prosthesis costs. The Medacta Endo Head is a product suitable to perform hemiarthroplasty on any hip joint whose acetabular conditions are satisfactory. The Endo Head ...
Femoral head diameter: 28 mm - 36 mm
1. Increased Fracture Strength. 2. Excellent Wear Properties. 3. Unlimited Biocompatibility.
SurgTech
... 2 inc Bipolar Liner Assembly Spec.: 38/22, 40/22, 42/22, 44/28, 46/28, 48/28, 50/28, 52/28, 54/28, 56/28, 58/28 Metal Femoral Head Spec.: 22M 22L
SurgTech
Femoral head diameter: 28 mm - 36 mm
... saves time in OR. 3. Locking groove fracture enhances stability and minimizes potential for rotation metal and ceramic femoral heads.
SurgTech
• Taper 12/14. • Implants have super polished surface.
• CoCr material. • Bipolar head’s inner part is polyethylene material. • Optimized biocompatibility. • Implants have a clamp locking mechanism.
Bipolar Head used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Femoral Stem Dual ...
Femoral Head Modular Ø 22 Mm 12/14 Mm used together products Acetabular Cup (Cemented) (10°) Acetabular Liner (10°) Acetabular Cup Poros Coated (Cementless) Acetabular Cup Dual Coated (Cementless) Femoral ...
Femoral Head Modular Ø 28 Mm 12/14 Mm used together products Bipolar Head Acetabular Cup (Cemented) (10°) Acetabular Liner (10°) Acetabular Cup Poros Coated (Cementless) Acetabular ...
Femoral head diameter: 22.2 mm - 28 mm
... Instrumentation used to determine implant size SPHERIC® RL : Femoral head retention ensured by retaining lip at its recess threshold. Chamfer at threshold of retaining lip delays ...
... options when selecting offset Modular design for optimised inventory Compatibility Can be used with TrinityTM modular heads in sizes 22mm and 28mm Compatible with all Corin 12/14 tapered stems
... approach to hip arthroplasty in which an all-metal bearing couple is used to preserve, rather than replace, a patient’s femoral head and neck. It was first implanted in July 1997, and was approved for ...
Smith & Nephew
... Co-Cr-Mo). 2. Modular Femoral Head is intended to be used with uncemented stem or cemented stem through 12/14 taper connection and articulate with dedicated range of modular liner or bipolar monoblock ...
Femoral head diameter: 28 mm - 36 mm
BioBall DELTA™ Ceramic Heads are part of the BioBall ® Adapter System. BioBall® Ceramic Heads should only be combined with BioBall® Adapters. BioBall® Metal Heads and the BioBall® Duo ...
Merete
... Connexion GXL®, our low wear, fracture tough polyethylene. This material also provides a new ‘option’ for using a ceramic femoral head in a revision scenario with the BIOLOX®OPTION.* Science Behind ...
Exactech
Bipolar Hip System
Femoral head diameter: 22 mm - 28 mm
Bipolar II can be used in hemi-arthroplasty which is indicated in the case of femoral neck fracture, trauma, and the early-stage avascular necrosis when the acetabulum remains intact.
... a turning edge chamfer; 2. The round edge avoids the collision between the ceramic liner and metal prosthesis; 3. Prevents edge wear when the ball head is slightly detached from the acetabular cup. Fixing ...
Femoral head diameter: 10 mm - 31 mm
Universal Hip Implants Size 10mm+0 - 1 Omm+2 10mm+4 Size 13mm+0 - 13mm+3 - 13mm+6 Size 16mm+0 - 16mm+3 - 16mm+6 16mm+9 - 16mm+12 Size 19mm+0 - 19mm+3 - 19mm+6 19mm+9 - 19mm+12
Femoral head diameter: 41 mm - 59 mm
... sphere. • Polytethylene part supplied with removable retention ring. • Two gripping holes in the retention ring to ease implant positioning.
EUROS
... fracture of the femoral neck, pain from destruction of the femoral head or acetabulum, resulting in impairment of joint function; 2. Patients with avascular necrosis of the femoral ...
Wuhan Yijiabao Biological Materials
Femoral head diameter: 22 mm - 40 mm
Femoral heads Surgival are used for total and partial hip arthroplasties. Their function is to replace the anatomical joint element, providing the necessary mobility for proper functioning. Femoral ...
Surgival
Femoral head diameter: 22.2 mm - 28 mm
The MOBIPOP® prostheses range consists of acetabular bipolar cups designed to replace partially the natural hip joint on first intention. Range of products: MOBIPOP® implants offer a wide choice in the reconstruction of the hip joint: Friction ...
X-NOV Medical Technology
Femoral head diameter: 28 mm - 40 mm
... cross-linked polyethylene. Ceramic ball heads reduce polyethylene wear to significantly less than 0.1 mm per year. Compared to metal/polyethylene solutions, BIOLOX /polyethylene wear couples reduce the rate of implant ...
Femoral head diameter: 22 mm - 36 mm
Mandatory product for femoral stems. The metallic femoral head is available for the Baumer and Eurocone cone, in two raw materials: – Austenitic Stainless Steel Cr Ni Mo ASTM F138; – ...
1.Made of Co-Cr-Mo alloy or Stainless Steel,highly polished surface with extremely low friction coefficient; 2.Highly accurate technology.All productsre tested with three-dimensional measurement; 3.Provide products of specific diameters ...
Beijing Chunli Technology Development
Femoral head diameter: 40 mm - 58 mm
... trial head into the acetabulum. The trial procedure can be done with the help of the femoral stem implant as well. Insertion It is recommended that the prosthesis ...
Femoral head diameter: 22.2 mm - 36 mm
... comprehensive range of femoral heads made of different materials for use on a 12/14 taper. The stainless steel heads are available different neck lengths. The chrome-cobalt heads ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining