Fibula compression plates
Length: 73, 229 mm
Hole diameter: 3.5 mm
Number of holes: 5, 3, 15 unit
The Vortex polyaxial plate system offers solutions for the whole body with 30 plates and only 3 screws and also ensures cross-referencing between instruments. Key advantages: – polyaxial locking plate ...
Trauma System plates and screws are intended to be used for internal bone fixation for bone fractures, fusions, osteotomies and non-unions appropriate for the size and design of the device. The large plate ...
Length: 56, 184 mm
Thickness: 2.3 mm
Hole diameter: 2.7, 3.5 mm
... reinforced polymer. •Polyaxial locking screws - up to 10° trajectory variation. •Circumference radiopaque marking outlining plate contour for positioning & follow-up. Features •Radiolucent: Superior fracture imaging. •Unparalleled ...
Length: 82, 107, 132 mm
... Anatomically pre-shaped plates reduce soft tissue irritation and do not require additional modelling. • Diaphyseal and metaphyseal fractures of the distal fibula (4F3). • Intra and extra articular ...
Intrauma
Hole diameter: 1.6, 2.7 mm
Number of holes: 5, 12 unit
► 1/3 Semi tubular Locking Plate ► Self-tapping Cortex Screw ► Cancellous Screw ► In both ends of the plate holes for 01.6 mm Kirschner wires
... in various lengths and number of holes for each type of plate. The use of cortical screws, self-tapping cortical screws and cancellous bone screws in different sizes are recommended for each plate model.
- Optimal Fit - Screw Trajectory - Fully Instrumented System - Pre-contoured Plates - Thin profile towards the joint line
... holes allowing reduction and stabilization of the Wagstaff fragment/AITFL to the plate • Anatomic medial malleolar plate o Patent-pending design (US29/719,840) o Specifically designed to allow buttress ...
Length: 102, 126, 150, 54, 78 mm
Thickness: 1.5 mm
Number of holes: 4, 6, 8, 10, 12 unit
This plate is indicated for fractures of ulna, radius and fibula shaft. Low Plate profile and rounded plate edges minimize tendon and soft tissue irritation
DTM - Deva Tibbi Malzemeler
Length: 64, 87, 98.5, 121, 199.7 mm
Thickness: 1.6 mm
Number of holes: 2, 4, 5, 7, 13 unit
... ankle joint. The plates are designed to be used with both locking and non-locking screws although locking screws provide stronger and more stable fixation. All the plates have compression ...
Indikation: As tension band, neutralization or buttress plate in fibula, distal ulna, olecranon and metatarsus.
... the ankle joint. The plates are designed to be used with both locking and non-locking screws although locking screws provide stronger and more stable fixation. All the plates have compression ...
Length: 3.5, 2.7 mm
3.5mm Distal Fibula Locking Plate (I) 3.5mm Distal Fibula Locking Plate (II) 2.7 / 3.5mm Distal Posterolateral Fibula Locking Plate 2.7/3.5mm ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining