- Laboratory >
- Immunology >
- Myoglobin test kit
Myoglobin test kits
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Result display time: 17 min
Sample volume: 0.1 ml
... increase in circulating myoglobin (e.g. renal failure), measurement of myoglobin in blood has been used as an early marker of AMI. Several studies proved that the measurement of myoglobin ...
... brain natriuretic peptide STAT (100T, 50T) Troponin I (100T, 50T) High Sensitive Troponin T STAT (100T, 50T) Myoglobin (100T, 50T) Myoglobin STAT (100T, 50T) Creatine kinase MB (100T, 50T) Creatine ...
Result display time: 14 min
... results, CLIA, high sensitivity ● Cost-effective, no unnecessary waste, single-use cartridge ● Comprehensive solutions, multi-test parameters
5 tests/box, 25 tests/box, 40 tests/box, 100 tests/box Certificates: CE, SGS ISO13485, ISO9001 Matching Equipments: Solid Phase Fluorescence Immunoassay System ...
5 tests/box, 25 tests/box, 40 tests/box, 100 tests/box Certificates: CE, ISO13485, ISO9001 Matching Equipments: Solid Phase Fluorescence Immunoassay System Manufactured ...
Test Panels including Cardiac Markers, Inflammation, Hormone, Diabetes etc.
... Description: The kit is used for quantitative detection of the concentration of myoglobin (Myo) in human serum, plasma or whole blood samples in vitro. Technical Parameters Target region - Serum, ...
【EXPLAIN】 The One Step Myoglobin/CKMB/Troponin I Combo Test Device (Whole Blood/Serum/Plasma) utilizes a combination of antibody coated particles and capture reagents to qualitatively ...
... This product is used to detect concentration of Myoglobin (Myo) in human serum and plasma. Myoglobin is an iron- and oxygen-binding protein found in the muscle tissue of vertebrates. In human body, myoglobin ...
Introduction: The creatine troponin complex, formed by cardiac muscle creatine troponin I (cTnI), troponin T (TnT) and troponin C (TnC), can adjust the interaction between actin and myosin. The concentration of cTnI is rare low in healthy ...
Introduction: Cardiac markers are used in the diagnosis and risk stratification of patients with chest pain, suspected Acute Coronary Syndrome(ACS) and Heart Failure(HF), etc. Advantage: 1. Equipped with special dropper consumables, ...
Result display time: 15 min
... 5. Room temperature storage. Specification Product Name: cTnI/Myo/CK-MB Test Kit Package Specification: 20 Tests/Box Storage Condition: The test ...
... fluorescence intensity of the test and the standard curve, the concentration of Myoglobin in the sample can be calculated by the MP Fluorescent Immunoassay Analyzer to show Myoglobin ...
Result display time: 15 min
... only TnI and TnT are found in the heart. In general, TnI is used in conjunction with other cardiovascular markers such as Myoglobin and CK-MB, and is more specific to myocardial injury and is characterized by an elevated ...
Result display time: 15 min
Myoglobin is a protein produced when the heart or skeletal muscle is damaged. The molecular weight is smaller than that of enzymes such as CK, so it is released into the blood before CK-MB when heart pain occurs, and ...
This kit is used to quantitatively determine the content of myoglobin in human serum in vitro. Background of Clinical Indications It is used for the auxiliary diagnosis of myocardial ischemia injury, ...
Result display time: 15 min
... items in human whole blood or plasma related to the heart and lungs, including high sensitive cardiac troponin I (hs-cTnI), myoglobin (MYO), creatine kinase isoenzyme (CK-MB), d-dimer (D-Dimer), N-terminal proBNP (NT-proBNP), ...
Result display time: 15 min
... coefficient of variation of the 99th percentile value is ≤10%. Myoglobin (Mb) is a hemoglobin that was first found in striated muscle cells (skeletal and cardiac muscle). Myoglobin binds to oxygen ...
Result display time: 10 min
This MYO (Myoglobin) Fast Quantitative TEST Kit is a blood test to measure the amount of MYO in multiple samples like whole blood, serum and plasma on LYOFIA® platform ...
... aid in the diagnosis of myocardial infarction The Acute Care™ myoglobin assay is an in vitro diagnostic test for the measurement of myoglobin in heparinized whole blood /plasma. Myoglobin ...
Result display time: 15 min
The Cardiac Combo Test is a lateral flow chromatographic immunoassay for the qualitative differential detection of Myoglobin, CK-MB and Troponin I in human serum, plasma or whole blood. It is intended ...
Result display time: 15 min
Sample volume: 0.075 ml
... . CK-MB rises 4 to 6 hours after a heart attack but is generally back to normal in a day or two. Myoglobin is a small protein that stores oxygen. Myoglobin is sometimes measured in addition to troponin ...
Beijing O&D Biotech Co., Ltd.
Result display time: 20 min
... sample myoglobin content exceeds a certain concentration range, in the detection line red band (T line),indicating that the sample is positive. Each person has a separate test box, consisting of test ...
Result display time: 5 min - 15 min
... is fixed with test lines (cTnI line, CK-MB line, Myo line) and a quality control line (C line). 3. When an appropriate amount of sample is added to the sample hole of the test card, the sample will ...
Result display time: 300 s
The Myo blood test kit is used for the determination of myoglobin (Mb) content in serum. Myoglobin is a heme protein found in the cytoplasm of the myocardium and skeletal ...
... CATEGORY - TESTS/KIT Histamine - ALLERGY - 96 Tests Human IgG Food Allergy - ALLERGY - 96 Tests Human IgG4 Food Allergy - ALLERGY - 96 Tests Total ...
Result display time: 20 min
Sample volume: 0.15, 0.1 ml
Specificity: 95, 98 %
cTnI/CK-MB/Myo Assay kit uses colloidal gold immunochromatographic method to detect Cardiac Troponin l, CK-MB and Myoglobin in human serum, plasma or whole blood, which is to diagnose ...
Result display time: 12 min
Sample volume: 0.01 ml
INCLIX TRF Myoglobin is for quantitative determination of Myoglobin in serum, plasma, and whole blood. The test is used as an aid to diagnose Acute Myocardial infarction (AMI). KEY ...
HUBI Cardiac 3—in—1 is one step in vitro diagnostic test based on immunochromatography. It must be used with HUBI QUAN pro and designed for quantitative détermination of CK-MB, Myoglobin and Cardiac ...
... resistance to certain concentrations of interfering substances such as immunoglobulins, haemoglobin, leucocytes, bilirubin, myoglobin, pepsin, albumin, human DNA, methylprednisolone, hydrocortisone, dexamethasone and ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining