Length: 1,300, 1,800 mm
Depth: 820 mm
Height: 2,070, 2,040 mm
... in a laminar or unidirectional air stream. Laminar Flow Cabinet – is used only for sample protection. Laminar Flow Cabinet ...
Biobase
Laminar Flow Cabinet-sample protection only Laminar Flow Cabinet is a work bench or similar enclosure, which creates a particles-free working environment ...
Biobase
Face velocity: 0.3 m/s - 0.5 m/s
Power: 180 W
Length: 500 mm
The mobile fume extractor is an purification equipment which can provide the partial high pure environment. The airflow is vertical laminar flow type. ...
Biobase
Depth: 830 mm
Height: 1,575 mm
... Class II Type B2 performance by complying with not only the biological safety cabinet standards of NSF/ANSI 49 but also the fume hood requirements of UL 1805 and ASHRAE 110. Overview The NU-565, a ...
Depth: 780 mm
Height: 2,289, 1,983 mm
... supply module at the top of the unit as well as in the exhaust module at the bottom to turn the work zone in between into a vertical “piston of air.” The transfer station’s supply impeller at the top of the “piston” draws ...
... allergen protection through a dynamic air barrier of 75 fpm (0.38 m/s) through the front of the cabinet. The HEPA filtered laminar downflow air of 60 fpm (0.30 m/s) provides animal protection within the ...
Length: 800 mm
Depth: 510 mm
Height: 935 mm
Protect your products from contamination with the 0 vertical laminar flow hood model MINISPACE. Meets ISO 14644 / ISO 5 Inclined and folding front window for perfect ...
Face velocity: 3 m/min - 5 m/min
Power: 180, 100 W
Length: 600, 800, 1,000, 1,200, 1,400 mm
Phamm Engineering’s great manufacturing flexibility makes it possible to produce non-standard models according to customer specifications.
Laminar Flow Hood with Lead GlassDedicated to the laboratory and industry use, specifically for the protection of the product manipulated. Moreover, ensures excellent laminar ...
Sterile Laminar flow hood in Class I not Biohazard designed for the protection of both operator and product. The flow activa hood is suitable for the ...
Length: 72, 48, 60, 96 in
Depth: 37.7, 39.2 in
Height: 59 in
... XStream allowed 0.00 ppm average level of tracer gas outside the fume hood. Although your safety officer will determine the actual face velocity setting for your laboratory, the ability of this hood ...
Labconco
Depth: 460 mm
Height: 700 mm
DFMZ’s VBM-200 Mini Vertical Laminar Flow Hood is built to provide clean air just about anywhere. Its unique size and plug and play design make it a great addition to ...
Depth: 70 cm
Height: 120 cm
... level of protection. Particles or fumes flow downward through the stainless steel work surface and contaminants are removed using several filters. Following the filtering of fumes ...
Power: 200 W
Length: 830 mm
Depth: 652 mm
... Nucleic acid amplification and thermocycling Positive pressure vertical laminar flow hood, compact (800 mm) with partial recirculation - designed for protection of ...
Angelantoni Life Science
Face velocity: 0.4 m/s
Depth: 580 mm
Height: 800 mm
... bypass leakage outside the cabinet. Redesigned DWS offers increased internal height. Description DWS Downflow Workstations are ductless fume hoods designed to protect the user and the environment ...
RFV2™ high efficiency fume hoods offer excellent containment performance and energy efficiency at lower face velocities than conventional hoods. RFV2™ hoods have passed ...
The EdgeGARD® VF is a vertical-flow recirculating air clean bench that provides protection for samples and work procedures where product protection and particulate control are required. ISO Class ...
... static stand with adjustable height feet. VLF Laminar Flow Cabinets are built to a very high standard using only the best quality materials and fan components. Experience has shown that VLF Laminar ...
... .99%. The HEPA filter is positioned above the work area of the Laminar Flow Hood providing vertical unidirectional airflow within the cabinet. This ensures a smooth ...
DFMZ's VCM Series of Vertical Laminar Flow Hoods create the ideal environment for excellent product protection, where particulates are not harmful to the operator. The ...
... shell for 360° visibility Digital UV light timer :01-59 minutes Extremely quiet operation < 49dBA ISO 5 vertical laminar flow air Lab event timer No ductwork required ...
Airclean Systems
Depth: 20 in
Height: 59 in
... Downdraft Station DDS fume extractor series removes harmful particles from the work area and helps you maintain a clean and healthy workplace. For restricted spaces, the low profile configuration allows ...
Power: 375 W
Length: 1,380 mm
Depth: 780 mm
This full sized 1.2 m cabinet provides plenty of room to work with sensitive products in a clean environment. Electrically operated front glass Tight seal closure system White painted steel working area ...
BioAir
... six steps of wind speed control; Independent control of UV light and lamp, timing range of sterilization is 0 to 999min; Vertical quasi closed table, the down airflow formed in the operation area can prevent the air ...
Shanghai Boxun Indusrty & Commerce Co.,Ltd
Uses: This series of product is high-precision thermostatic equipment with functions of illumination and humidification. It is widely used in plant cultivation, seed germination, seed growing, histocyte and microbe culturing, as ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining