Esophageal stent BD
polymerself-expandingbare

esophageal stent
esophageal stent
esophageal stent
esophageal stent
esophageal stent
esophageal stent
esophageal stent
Add to favorites
Compare this product
 

Characteristics

Type
esophageal
Material
polymer
Options
self-expanding, bare, bioresorbable
Diameter

18 mm, 20 mm, 23 mm, 25 mm
(0.709 in, 0.787 in, 0.906 in, 0.984 in)

Length

60 mm, 80 mm, 100 mm, 135 mm
(2.362 in, 3.15 in, 3.937 in, 5.315 in)

Description

The BD Stent is a worldwide unique self-expandable esophageal biodegradable stent that disintegrates in the human body usually 3 to 4 months after the implantation. Therefore, it is an ideal solution for temporary use in benign indications, where it is not necessary to extract it from the body like other non-degradable stents (including possible extraction from the stomach due to stent migration). In specific cases, custom-made production is possible. BD Stent is intended for patients aged 18 and older and is indicated for management of refractory benign esophageal stenoses: - refractory esophageal stenoses (peptic, caustic, or anastomotic) in which the standard therapy with repeated dilation failed. The BD Stent degrades in the human body usually in 3 to 4 months. This reduces the number of interventions and hospital visits. The stent is made of polydioxanone, an absorbable material (polymer) used in medicine as a surgical suture for more than 30 years. Stent integrity and radial force are maintained for 6 to 8 weeks after implantation. Subsequently, the radial force gradually decreases until the degradation of the material after 3 to 4 months. The pH value affects the stent degradation process. At higher pH, stent degradation is slower, at lower pH, stent degradation is faster. Low migration is achieved by uncovered stent design. Polydioxanone is not visible under X-ray, so the stent is equipped with gold markers - 3 pieces at both ends and 1 piece at the midpoint of the stent. MRI compatibility - "MR Conditional", compatible with 1.5 Tesla and 3 Tesla static magnetic field.

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

ESGE Days 2024

25-27 Apr 2024 Berlin (Germany) Stand 23

  • More information
    MEDTEC live 2024

    18-20 Jun 2024 Stuttgart (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.