Biochemistry reagent
enzymelaboratorydiagnostic

biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
biochemistry reagent
Add to favorites
Compare this product
 

Characteristics

Type
enzyme
Applications
for quality control, diagnostic, laboratory, for biochemistry
Format
liquid, lyophilized, powder
Tested parameter
alkaline phosphatase, total proteins, albumin, glucose, creatinine, sodium, calcium, potassium, urea, bilirubin, cholesterol, triglycerides
Other characteristics
high-sensitivity

Description

SFRI manufactures a COMPLETE range of enzymes, substrats, specific proteins and electrolytes. For each, an easy-to-understand application notice can be provided on the instrument HEREAFTER. Upon demand, some other applications can also be given. • ALL SEMI-AUTO ANALYZERS • ABBOTT C-series • OLYMPUS AU-series • BECKMAN COULTER Synchron CX-series • BIOSYSTEM A-15 A-25 • HITACHI 704-717 911-912-917 • KONELAB • LISA 200-300 • MINDRAY BS200 - BS380 - BS400 - BS800 • DIRUI CS300 - CS400 - CS800 - T240 • PRESTIGE 24i • TARGA BT-series • COBAS • ERBA XL200 - 300 - 640 • SIEMENS ARCHITECT • SNIBE • ALL SEMI-AUTO ANALYZERS • ABBOTT C-series • OLYMPUS AU-series • BECKMAN COULTER Synchron CX-series • BIOSYSTEM A-15 A-25 • HITACHI 704-717 911-912-917 • KONELAB • LISA 200-300 • MINDRAY BS200 - BS380 - BS400 - BS800 SETTING THE TEST is simple as ABC. Let’s take a real example : GLUCOSE LR 1. Wavelenght : 510 (500-550) nm 2. Temperature : 37°C 3. Optical path : 1 cm 4. Reaction : «end point» 5. Select the glucose test 6. Calibrate and control 7 Aspirate the sample 8. Wait for result And that’s it ! READY-TO-USE LIQUID REAGENTS GAIN OF TIME No preparation --> No pre-treatment, no reconstitution of tablets or powder. R1 & R2 already measured. No more pipets. Never wait just open and use. ECONOMICAL No need to prepare a full house of reagent unlike with lyophilized reagents. Open a bottle when you need it, and manage your consumption and the expiry dates better. No water needed - Economy 1 no risk of bad demineralized water. Don't lose any product manipulating. PACKAGING FITS THE REAL NEED OF LABS.

Catalogs

No catalogs are available for this product.

See all of SFRI‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.