- Laboratory >
- Hematology >
- Benchtop coagulation analyzer
Benchtop coagulation analyzers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Throughput: 40, 60 p/h
Weight: 53 kg
Length: 660 mm
... s an advanced, fully automated random access analyzer for Complete Hemostasis. This seven channel coagulation analyzer redefines the benefits in its class. This system is ideal for mid-high ...
Weight: 1 kg
Length: 216 mm
Width: 75 mm
One channel semi-automated coagulometer which performs measurements of all clotting assays as well as D-Dimer. It is ideal for small laboratories. Product Features: Clotting assays by light scattering at 640 nm Immuno-turbidimetric ...
Throughput: max 225.0 p/h
Weight: 85 kg
Length: 1,000 mm
The Yumizen G1550 automated analyzer meets those daily expectations thanks to its unique features Clotting, immunologic and chromogenic assays Integrated nephelometric and turbidimetric measuring channels Up to ...
HORIBA Medical
Throughput: max 225.0 p/h
Number of sample positions: 150 unit
Test storage capacity: max 1000000.0 unit
The Yumizen G1550/G1500 automated analyzer meets those daily expectations thanks to its features: Routine and specialized testing in a single analysis system Liquid and ready-to-use reagents for 80% of the laboratory ...
HORIBA Medical
Yumizen G800 Fully Automated Coagulation Instrument Smart way to test 4 independent measuring channels 14 cooled + 4 reagent embedded positions 10 samples + 5 STAT sample positions Automatic reflex and rerun ...
HORIBA Medical
Weight: 850 g
Wondfo Optical Coagulation Analyzer, used together with the test reagents, delivers quick lab-quality results that support clinical decisions in cardiology, surgery and intensive care. The first POCT ...
... Product Detail Analyzer Introduction SF-8050 use voltage 100-240 VAC. SF-8050 can be used for clinical test and pre-operative screening. Hospitals and medical scientific researchers also can use SF-8050. Which adopts ...
Number of reagent positions: 16 unit
1. Designed for Mid-Large level Lab. 2. Viscosity based (Mechanical clotting) assay, immunoturbidimetric assay, chromogenic assay. 3. External barcode and printer (not provided), LIS support. 4. Original reagents, cuvettes and ...
Number of reagent positions: 4 unit
1. Viscosity based (Mechanical) Detection system. 2. Random tests of clotting tests. 3. Internal USB printer, LIS support. Technical Specification 1) Testing Method - Viscosity based Clotting method. 3) Testing Position ...
Optics & mechanism technologies integrated for reliable results Single-serving package for cost saving and high efficiency Adjustable touchscreen and interior lighting to maximize the convenience Intelligent design to optimize the workflow
The STA Compact Max 3 offers significant performance improvements and includes the EPC (expert pre-analytical check) module. This EPC module controls fill volumes of all types of tubes and detects haemolysed, icteric and lipemic samples, ...
... interface making it the ideal solution for Hemostasis testing in low-volume labs. The STA Satellite Max is a Hemostasis analyser designed specifically for “satellite” labs looking for a device that meets their needs ...
... robustness made its high reputation over the decades. These semi-automated analysers can therefore be found in labs of various size: with either small volume of coagulation tests or as back-up of larger ...
Number of sample positions: 27 unit
Number of reagent positions: 27 unit
Weight: 53 kg
• Methodology: Clotting, Chromogenic, Immunologic • 72 cuvettes on board
Number of sample positions: 24 unit
Reagent volume: 0.03 ml
Number of reagent positions: 6 unit
- Principle: Scattered light with percentage analysis. - Light sourse: Durable LED detector (470nm). - Test time: 20-60 seconds on average. - Electronically linked pipette. - QC and calibration program incorporated.
... Stability check Ergonomic design Three Parameter - PT, APTT and Fibrinogen Technology Semi automated single channel coagulation analyzer which is based on Photometry principle (@ 578 nm).
The miniClot 04 is a semi-automatic analyzer for the determination of all coagulative, chromogenic and immuno-turbidimetric parameters. Thanks to its reading system with 3 channels at 405 nm and one at 578nm and the ...
Throughput: 300 p/h
Number of sample positions: 52 unit
Number of reagent positions: 6 unit
i-CLOT 52 is a high-throughput random access hemostasis analyzer for medium/high volume laboratories performing routine and special tests. With its innovative system it guarantees efficient and reliable ...
Weight: 25 kg
Length: 54 cm
Width: 42 cm
VET CLER is the smallest automatic coagulometer for veterinary medicine. The main feature of the instrument is the use of pre-dosed and sealed strips which allow you to perform coagulation and immunoturbidimetry ...
Easy-to-use single-channel instrument With micro-processor for programming parameters and making calculations Measuring unit: • Controlled at 37.4°C +/- 0.4° • 1 operating measuring channel • 1 reagent position • 4 cuvette incubation ...
Spinreact
Throughput: 60 p/h
Sample volume: 0.01, 0.005, 0.05 ml
Test storage capacity: 3,000 unit
... analyses Dedicated interface to Sysmex’s online services Colour LCD touch screen and integrated barcode reader Robust analyser that will serve you for years The CA-620 is a compact, fully automated haemostasis ...
Sysmex Europe
Throughput: 400, 282 p/h
The CS-5100 Hemostasis System is a random-access, high-volume coagulation analyzer. Simultaneous multiwavelength, smartly designed PSITM technology enables labs to achieve high-quality results on the ...
Siemens Healthineers - Laboratory Diagnostics
Providing fast, actionable results to help you reduce risks, complications and costs The TEG 5000 hemostasis analyzer system is a diagnostic instrument that provides comprehensive whole blood hemostasis ...
Weight: 0.5 kg
Width: 19 cm
Height: 5 cm
... for intrinsic and common coagulation pathway disorders. For use with fresh whole blood. Validated for canine and feline use. Citrate aPTT Activated partial thromboplastin time test to screen for intrinsic and common ...
H 2600 AUTOMATIC COAGULATION ANALYZER Reliable Laboratory Partner H 2600 Automatic Coagulation Analyzer adopts humanized design concept. Highly efficient and stable ...
Throughput: 200, 320 p/h
Number of reagent positions: 70 unit
Weight: 90 kg
The devices of the Thrombolyzer series are fully-automatic coagulation analyzers for in-vitro diagnostics. The patented measuring system guarantees reliable measurement results in precision and correctness. The ...
Behnk Elektronik
Four-channels thromboela-stogram
ChongQing NanFang Numericl Control Equipment CO.,LTD
The Helena AC-4 is a fast, flexible, accurate photo-optical, fully automated coagulometer suitable for clotting, chromogenic and immunoturbidimetric assays using plasma. Photo-optical 4 x laser optics utilising 405nm ...
Throughput: 60, 40 p/h
Number of sample positions: 27 unit
Number of reagent positions: 23 unit
Advanced random access system for clotting, immunologic and chromogenic assays for routine and STAT testing. Simple, desktop analyser Bi-directional LIS communication Barcode reader for sample ...
Erba Lachema
Number of sample positions: 16 unit
Number of reagent positions: 4 unit
High quality sample pipettor; Advanced dual magnetic circuit bead method; Low reagent consumption
Guilin Urit Electronic Group Co.,Ltd
... Designed to accommodate a variety of applications across a broad range of laboratory testing, DT 100 is a fully automated bench top coagulation analysers, ideal for mid- to high-volume with full walkaway ...
Tcoag
Throughput: 100 p/h
Sample volume: 0.005 ml - 0.17 ml
Number of sample positions: 40 unit
Small in size, and multiple in function. >Reagents, samples and cuvettes on-board adding available. >Tilted reagent holder to reduce dead volumes. PT, APTT, FIB, TT are mandatory items before surgery for security warning and reducing ...
Throughput: 60, 50 p/h
Sample volume: 0.15 ml
Number of sample positions: 27 unit
Easy to use: Touch screen, intuitive windows-based software, continuous load Low maintenance: only two consumables and less than 0.5 L/h water consumption/h Complete diagnostics: global and specialty tests, through three measurement ...
Wiener Lab Group
-Clotting, Chromogenic and Immunoturbidimetry method -Continuous cuvettes loading, maximum load 1000 cuvettes -Multifunctional probe, collision protection, liquid level detection, Inventory check and clot detection, reagent ...
Rayto Life and Analytical Sciences
Throughput: 220, 110, 40, 25 p/h
Number of reagent positions: 29 unit
Weight: 75 kg
Highly integrated auto system Original tube & autoloader Reliable Precise control module Three detection methods with high sensitivity Efficient Independent STAT position One position for multiple items Safe Anti-pollution ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining