Result display time: 7 s
Memory capacity: 1,000 unit
Weight: 73 g
... The Microlife glucose meter Gluco-A+, provides high accuracy and consistency in testing patients' blood glucose, through advanced tri-electrodes glucose sensing technology, ...
... ColorSure® technology instantly shows if your glucose reading is low, high, or in range OneTouch Reveal® mobile app automatically logs results, tracks patterns, and enables you to share data with your care team Use with OneTouch ...
Result display time: 15, 10, 60, 5 s
Memory capacity: 1,000 unit
Weight: 57 g
... (POCT) environments. This device enables healthcare professionals to measure blood glucose, blood ketones, total cholesterol, triglycerides, uric acid, hemoglobin, and lactate using a ...
TaiDoc Technology
Result display time: 5, 10 s
Memory capacity: 1,000 unit
Weight: 58.3 g
... 4289 is intended to be used for the quantitatively measure the
blood
glucose, ketone,
lactate and Uric Acid in fresh capillary whole
blood.
Diabetic Monitor TD-4289 (Diabetic ...
TaiDoc Technology
Result display time: 10, 5 s
Memory capacity: 1,000 unit
Weight: 67.5 g
... the quantitatively measure the
blood
glucose and β-ketone in fresh capillary whole
blood.
Diabetic
Meter TD-4279 (Diabetic Monitor) have automatic test strip recognition function.
Using ...
TaiDoc Technology
Result display time: 5 s
Sample volume: 0.0005 ml
Memory capacity: 500 unit
... Blood Glucose Meters are often used by diabetic patients to monitor blood glucose levels constantly in order to stay healthy. Visiting labs 5-6 times a month is quite ...
Sensa Core Medical Instrumentation Pvt. Ltd.
Result display time: 5 s
Sample volume: 0.0005 ml
Weight: 10 g
... problems related to glucose strip by significantly enabling sensitive and accurate performance of glucose strip in a cost-effective way. Technical Specfications Test Principle - Determination of glucose ...
Sensa Core Medical Instrumentation Pvt. Ltd.
Result display time: 5 s
Sample volume: 0.0005 ml
Weight: 10 g
... problems related to glucose strip by significantly enablingsensitive and accurate performance of glucose strip in a cost-effective way. Technical Specfications Test Principle - Determination of glucose ...
Sensa Core Medical Instrumentation Pvt. Ltd.
Result display time: 5 s
Memory capacity: 500 unit
Weight: 70 g
... displayed in just 5 seconds from blood detection. 0.3 µL micro sampling Only a 0.3 µL blood sample is needed to perform measurement. Specifications Test item - Blood glucose ...
Arkray
Result display time: 5 s
Memory capacity: 300 unit
... Tags – easier way to analyze data Temperature 10°C - 40°C(50°F - 104°F) Humidity 10-90% RH Hematocrit 35 - 55% Test Sample Capillary Whole Blood from Fingertip, Palm and Forearm Sample Volume >0.5 μ Measuring ...
Diagnosis
Result display time: 5 s
Memory capacity: 1,000 unit
Weight: 51.5 g
... averages Post-meal flagging Specifications Sample Type - Fresh capillary whole blood Sample Size - 0.5 μL Measurement Range - 20-600 mg/dL (1.1-33.3 mmol/L) Hematocrit - 15-65% Dimension - 93 x 47 x 15 mm Calibration ...
i-Sens
Result display time: 8 s
Memory capacity: 250 unit
Weight: 5.3, 1 kg
... Glucose oxidase Minimum sample volume 1ul Hematocrit range 30%- 60% Auto-coding Measurement range: 1.1mmol/L- 33.3mmol/L(20-600mg/dl) Operation temperature 10°C - 40°C 2 AAA batteries Strip reject ...
Jiangsu Yuyue Medical Equipment & Supply
Result display time: 5 s
Memory capacity: 500 unit
Weight: 54, 64, 59 g
... lightweight, 2 in 1 Blood Glucose and Ketone monitoring unit. It also features a wide Hematocrit range, uncompromised accuracy and is suitable for both professional and home use. 2 in 1 Blood ...
BIONIME
... plans. GDH-PQQ enzyme-based meter systems are known to have the potential for inaccurate results due to interference. Trividia Health has discontinued the TRUEresult Blood Glucose Meters, ...
Result display time: 5 s
Memory capacity: 730 unit
Weight: 46 g
... settable acoustic alarms Averages: Over 1, 7, 14, 30, 60, 90 days Dimensions: 85.5 mm (L) x 56 mm (W) x 18.2 mm (H) Meter Operating Conditions: Temperature: 4-30 °C Relative Humidity: 20 - 90% ...
... Glucose Monitoring for Life Science Research Nova Biomedical StatStrip® Xpress Accurately monitor blood glucose levels that are free from interferences in laboratory animals. It is the preferred reference ...
Result display time: 5 s
Sample volume: 0.0007 ml
Memory capacity: 300 unit
... The BeneCheck Uni Blood Glucose Monitoring System is designed for diabetes care. It uses electrochemistry as its principle for measuring blood glucose levels. The system is compatible ...
Result display time: 5 s
Memory capacity: 500 unit
Weight: 58 g
... 3 in 1 Monitor for health screening Test Sample Capillary Whole Blood Measuring Unit mg/dL or mmol/L Average 20 - 600mg/dL (1.1 - 33.3mmol/L) Reminder Alarm 7/14/30 days Power Supply 2 AAA batteries Battery Life Approximately ...
Result display time: 5 s
Memory capacity: 180 unit
Weight: 50 g
... Blood Sample Type - Capillary and Venous Whole Blood Blood Volume - 0.5µL Acceptable Hematocrit Range - 20%~60% Measuring Range - 20~600mg/dL (1.1~33.3mmol/L) Measuring Unit - mg/dL ...
Visgeneer - eBmonitor
Result display time: 6, 5 s
Memory capacity: 500 unit
... Blood sample type Fresh capillary whole blood Fresh capillary and Venous whole blood Blood sample volume 0.5 ㎕ Measurement Unit mg/dL or mmol/L (non-switchable) Result range 20~600 ...
Result display time: 8 s
Memory capacity: 250 unit
... Metering unit: mg/dL; mmol/L Blood volume: 1μl Measuring range: 20mg/dL ( 1.1mmol/L )~ 600mg/dL( 33.3mmol/L ) Average results: 7 days, 14 days, 1 month, 2 months and 3 months Hematocrit range: 30%~60% Ambient temperature ...
Result display time: 5 s
... date. How-to-use Insert the blood glucose test strip into its slot; the meter will tum on automatically. The meter is ready for use when it shows the test strip image, blood ...
Result display time: 5 s
Memory capacity: 1,000 unit
Weight: 63.2 g
... diabetes management. More than just a blood glucose test, the FORA 6 series provides a holistic approach to diabetes management, allowing a look at significant parameters such as cholesterol, uric acid, ketone, hemoglobin ...
ForaCare Suisse AG
Result display time: 7 s
Weight: 45.6 g
... Simple and reliable to measure blood sugar. To patients with diabetes, DIAVUE ® is created to introduce an enjoyable and cherishing experience. DIAVUE ® provides a combination of safe, convenient, and user-friendly. Join DIAVUE to ...
BioCARE Corporation
Result display time: 5 s
Memory capacity: 450 unit
Weight: 52.4 g
... the necessary functions you need for daily blood glucose test. Our mission is to offer reliable, accurate and user-friendly BGMs. Code Free GDH-FAD: Minimizing the interference of Xylose Insufficient Blood ...
Result display time: 5 s
Memory capacity: 500 unit
... settings, as in critical cases many other parameters in the blood can create complications in glucose testing • Effortless wireless synchronization: • Accurate blood glucose measurement: ...
Result display time: 5 s
Memory capacity: 1 unit
Weight: 16 g
... We are superior Blood Glucose Meter Products Manufacturer in Taiwan, offering Diabetes Test Meter, Diabetes Test Strip, Diagnostic Meter, Diagnostic Test Strip, and Medical ...
OK Biotech
Result display time: 10 s
Memory capacity: 180 unit
Weight: 28, 31 g
... .H Meter Storage Conditions (Transportation Conditions) Temperature Humidity - Meter: -10 - 60°C (14 - 140°F) ^ 95% R.H Strips: 4~30°C (39.2-86T) < 95% R.H Resolution - 1 mg/dL(0.1 mmol/L) Sample Type - Finger eapillary ...
Result display time: 10 s
Memory capacity: 300 unit
... detection of insufficient sample GOD enzyme has high specificity with no interference from maltose, galactose Optional individually packaged test strips available Feature Specification Sample Size 0.5 μL Hematocrit ...
ACON DIABETES CARE
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group