- Secondary care >
- Cardiology >
- Hydrophilic guidewire
Hydrophilic guidewires
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... >
Product Description
The Ultraskin
hydrophilic guide wire combines a nitinol core with a PU jacket containing tungsten carbide for enhanced fluoroscopic visibility. The durable
hydrophilic coating ensures ...
... technique and
hydrophilic coating to assist catheter tracking.
Product features
- Core-to-tip or shaping ribbon construction
- Nitinol (NiTi) + stainless steel core
- Patented welding technique
- Hydrophilic
... urinary tract treatment, and used for placing instruments with endoscope. Product features · Soft tip design Soft hydrophilic tip for smooth passage through obstructions and stenoses to reduce trauma · Hybrid material Nitinol ...
... Disposable urinary hydrophilic guidewire is applicable for guiding catheter and placing instruments in the treatment of urinary tract with an endoscope. Product features · Nitinol core Provide kink resistance and ...
... appearance Blue and white stripes allow for clear positioning of the guidewire · Provide various tip configurations Angular,Standard and Ultra-thin · Hydrophilic coating Hydrophilic coating Tip ...
... PTFE jacket, Nitinol core Hydrophilic flexible tip facilitating safe access and good maneuverability Highly radiopaque black and yellow strips for improved visualization Kink-resistant Nitinol shaft providing good control and safe ...
... TPU jacket, Nitinol core Features Hydrophilic coating and TPU jacket offering low friction surface facilitating advancement Ultra-elastic kink – resistant Nitinol core providing good torqueability Floppy tip for reliable and safe navigation ...
... exchange of medical devices during urological procedures. The BiWire has a nitinol core, flexible tips at both ends, a hydrophilic coating, and one-to-one torque. The wire guide has a straight tip at one end and an angled tip at the ...
... trackability 2、Nitinol core design: for excellent durability and tip shape retention 3、Tungsten based polymer jacket with hydrophilic coating: enables enhanced visualization and steering ability 4、Dual core technology: for smooth transition ...
INT Medical Instruments
... PORTER® Guidewires feature one-piece core wire providing 1:1 torque transmission to the guidewire tip. PORTER® Guidewires provide excellent support, visibility and steerability. CROSSER® Catheter Delivery Unique ...
... Product Name: Conger™ Plus Hydrophilic Guidewires Conger™ Plus Hydrophilic Guidewires are designed to facilitate the subsequent introductions of intravascular devices into peripheral ...
... easy advancement Precise torque response for secure control when sub-selecting distal and angulated branch vessels Durable hydrophilic coating to facilitate crossing of tight lesions Stiff and standard versions accommodate a wide range ...
... construction
- Platinium tip for high radiopacity
- PTFE coating for reduced shaft friction
-
Hydrophilic for reduced tip friction
Data:
- Dimension – Ø 0,014”/0,36 mm
- Length ...
SP Medical
... One core construction
- Dimension – Ø 0,014”/0,36 mm
- Length
SP Medical
... procedures.
Description:
- High radiopacity
- Nitinol core for kink resistance
- Hydrophilic surface for reduced friction
- Availiable with different tip and shaft flexibilities
- Double
SP Medical
... simultaneous rotation and excellent kink resistance. - 3 steps, no U-turn risk. - The guidewire of 0.025 inch provides the same supporting strength as the guidewire of 0.035 inch.. ...
... The urological guidewire is used in interventional urinary surgery to guide and assist the catheter to reach the exact position. It is for single-use only. Features 01 The soft head and hydrophilic design can ...
Used for guiding instruments and for single use when entering non-vascular lumens during urological surgeries.
... design of tip and core wire, impossible for falling off. *Core-to-tip design provides 1:1 torque ratio Guidewire has Ultra-smooth hydrophilic head, small friction at the head end of guide wire and smooth intubation. Various ...
... pressure suction opening, the use pressure can be effectively adjusted manually to improve the surgical field of view · Hydrophilic coating at the surface, has great lubrication performance, and can reduce surface friction ·Smooth ...
... ·The front end is designed as medical stainless steel spring, which has excellent flexibility, and can reduce the resistance of inserting into the bending cavity of human body, prevent mucosal tissues from being damaged, and develop clearly under X-ray ·It ...
... –Provides comfortable access thanks to the hydrophilic and soft tip –Clearer opaque image inside the body thanks to the dual-color body design -Nitinol material resistant to breakage and twisting ...
Plasti-med
... – Provides easy access even in narrow anatomies thanks to the hydrophilic coating – Provides comfortable access thanks to the soft tip – Nitinol material resistant to breakage and twisting ...
Plasti-med
... – Provides easy access even in narrow anatomies thanks to the 50 cm Hydrophilic coated first part – Comfortable access thanks to the soft tip – Nitinol material resistant to breakage and twisting ...
Plasti-med
... during urological procedures. The MEDpro Guide Wires are available in stainless steel PTFE coated Ever Green, Nitinol hydrophilic coated, zebra and black & white. MEDpro Guide Wires are supplied in sterile peel-open packaging and ...
... Hydrophilic flexible tip for easier access, creating a low friction surface which reduces trauma Nitinol core wire with blue & white sleeve for excellent visualization under X-ray Excellent stiffness of shaft provides good control and ...
... Hydrophilic coating for easier access, creating a low friction surface which reduces trauma; Tapered tip for atraumatic access, and to facilitate access past obstructions; Nitinol core wire which allows maximum deflection without kinking; Available ...
... off; · Various specifications are available according to clinical requirements, such as a stiff guidewire, plastic-coated guide wire, zebra guidewire, etc. ...
... 1.Good flexibility and bending resistance; 2.Hyper-slippery PTFE coating, make it easy and smooth for insertion; 3.Accurately guide the catheter or instrument to the designated location or lesion location. Product order information Specification: ...
Tianck Medical
... 1. Guide and assist the catheter to reach the exact location of the arteries and veins. 2. With a smooth top transitions, guide wire can reduce the damage of blood vessel. 3. Have good visibility under the endoscope image and X-ray image, which is convenient ...
Tianck Medical
... 1. Guide and assist the catheter to reach the exact location of the arteries and veins. 2. With a smooth top transitions, guide wire can reduce the damage of blood vessel. 3. Have good visibility under the endoscope image and X-ray image, which is convenient ...
Tianck Medical
... ENTER POLYMER GUIDE WIRE Hydrophilic coating for complete low friction maneuverability Super-elastic nitinol core Kink resistance Precise torque control ...
Balton
... crossing tortuous anatomy. Lotus IITM Guidewire is indicated for a broad range of coronary applications and can thus serve as ideal first choice wire.vailable to cross all lesions. The new LotusTM II Guidewire is ...
Rontis Medical
... ●Ultra-smooth hydrophilic guidewire Ultra-smooth hydrophilic coating reduces friction for a ureteral access that is more reliable. ●Hybrid guidewire A guidewire that ...
Zhejiang Yigao Medical Technology
... always works with J catheter and disposable minimally invasive dilation and drainage set to support and guide. Daxan hydrophilic coating can absorb and maintain liquid, designed to reduce the friction, allowing minimal irritation during ...
... Available with Lunderquist Type PTFE Coated Guide Wire (Box of 10 units) Lunderquist Guide Wire (Box of 10 units) Hydrophilic Nitinol Guide Wire (Box of 10 units) ...
... AcePTFE Guidewires are used for percutaneous vessel entry to facilitate subsequent introduction(s) of an intravascular device. This device is Supplied sterile in a peel-open pouch. Intended for single use only.. Used for negotiating ...
Ace Medical Devices
... axis • Improved torqueability allowing to achieve canalization and advance the guidewire without excessive torqueing until the lesion has been traversed • Hydrophilic coil coating Radiopaque Segment • 3 cm Platinium ...
... (U) •Length (cm) •Diameter (inch) PTCA GUIDEWIRES Featuring: •PTFE coated optional hydrophilic coated •190 cm standard length •Diameter 0.014" •Unitary core construction •Straight tip hydrophilic ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group