... Product Detail Analyzer Introduction Fully Automated Coagulation analyzer SF-9200 can be used for clinical test and pre-operative screening. Hospitals and medical scientific researchers ...
Beijing Succeeder Technology Inc.
Number of reagent positions: 42 unit
... 4. Original reagents, cuvettes and solution for better results. 5. Cap-piercing optional. Fully automated coagulation analyzer SF-8200 adopts clotting and immunoturbidimetry, chromogenic method ...
Beijing Succeeder Technology Inc.
... Product Detail Analyzer Introduction SF-8050 use voltage 100-240 VAC. SF-8050 can be used for clinical test and pre-operative screening. Hospitals and medical scientific researchers also can use SF-8050. Which adopts ...
Beijing Succeeder Technology Inc.
The STA R Max 3 is a versatile analyser that will adapt to any type of laboratory set-up, for an equivalent performance whether used alone or integrated into an automated track. It is supported by a range of reagents ...
The STA Compact Max 3 offers significant performance improvements and includes the EPC (expert pre-analytical check) module. This EPC module controls fill volumes of all types of tubes and detects haemolysed, icteric and lipemic samples, ...
... interface making it the ideal solution for Hemostasis testing in low-volume labs. The STA Satellite Max is a Hemostasis analyser designed specifically for “satellite” labs looking for a device that meets their needs ...
Throughput: 120 p/h
Weight: 85 kg
Width: 760 mm
Great routine analyser with a broad portfolio of specialty testing Proven, reliable technical performance with advanced CS-technology Sample integrity testing to protect result quality from pre-analytical variables Minimal ...
Sysmex Europe
Throughput: 380, 325 p/h
Number of reagent positions: 90 unit
Weight: 155 kg
... System, one of the most widely used fully automated hemostasis analyzers, delivers accurate and precise results. The high-speed, random-access analyzer performs clotting, chromogenic, immunologic, ...
Throughput: 60, 40 p/h
Number of sample positions: 27 unit
Number of reagent positions: 23 unit
Advanced random access system for clotting, immunologic and chromogenic assays for routine and STAT testing. Simple, desktop analyser Bi-directional LIS communication Barcode reader for sample ...
Throughput: 60, 50 p/h
Sample volume: 0.15 ml
Number of sample positions: 27 unit
... the whole service: Bidirectional connection Main features: 3 measurement methods: coagulometric, chromogenic and Immunologic. Bidirectional data transmission Has automatic dilution, calibration and retest ...
Throughput: 90, 180 p/h
-Clotting, Chromogenic, Immunologic measuring methods -auto loader for cuvettes -User-friendly operation software -Bidirectional LIS system -STAT sample priority -Reagent open system, close system on request -Barcode ...
Rayto Life and Analytical Sciences
Throughput: 220, 110, 40, 25 p/h
Number of reagent positions: 29 unit
Weight: 75 kg
Highly integrated auto system Original tube & autoloader Reliable Precise control module Three detection methods with high sensitivity Efficient Independent STAT position One position for multiple items Safe Anti-pollution ...
Throughput: 100 p/h
Sample volume: 0.012 ml - 0.1 ml
Number of sample positions: 8 unit
Sample Tray 36 Probe heating YES liquid level detection YES Reaction System Incubation Temperature 37°C±0.1 Reaction Cuvette 200 Operation System STAT Faction - YES Bar Code Reader - Optional Operating ...
Zircon Biotech Co., Ltd
Sample volume: 0.15 ml - 0.3 ml
Number of sample positions: 5 unit
Number of reagent positions: 6 unit
... SPECIFICATIONS General specifications: System Random Access, Bench top, Automated Haemostasis analyzer Measuring principle Clotting & Immunologic Operation External Windows based PC ...
Throughput: 300 p/h
High-throughput, random-access hemostasis analyzer for mid/high-volume laboratories performing routine and special assays. Innovative system ensures efficient, reliable results with built-in QC features. ...
Diagon Ltd.
Throughput: 110, 100 p/h
Number of sample positions: 32 unit
Number of reagent positions: 16 unit
... magazine for 464 tests General • Continuous loading • STAT sample management • Chronometric, Chromogenic and Immunologic tests Samples & reagents • 8 calibrator and control positions • Internal barcode ...
Throughput: 400 p/h
Number of sample positions: 80 unit
Number of reagent positions: 39 unit
... The present blood coagulation analyzer have TWO detection mode: 1, Optical coagulation analysis technic---low cost, but uncertainty at special samples like jaundice, lipid ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining