Weight capacity: 200 kg
... sores. Safe Non Turning Design Straps located on base of mattress secure the overlay to the mattress, No need for mattress turning. CPR Valve Easy and straightforward CPR deflation, air ...
Pe & Le Enterprise Ltd.
... The SelectAir® Low Air Loss Mattress Replacement System is quiet, portable, lightweight, cost-effective and very reliable. If individuals require microclimate control, then SelectAir Low Air Loss Systems ...
ROHO
Thickness: 13 cm
Weight capacity: 40 kg - 120 kg
... Large cell alternating pressure system with mattress pad with static function This large cell antidecubitus alternating pressure system of the aks-standard class is suitable for decubitus up to stage ...
aks - Aktuelle Krankenpflege Systeme
... This option includes an extraction unit and a mattress with cut-out. The major feature of the extraction unit is the cut-out in the mattress which does not affect its functionality or comfort. It is possible to install ...
Thickness: 6.4 cm
... Main technical indicators: Power supply voltage: AC220 V ~ 240 V / 100 ~ 120 V, 50 Hz / 60 Hz Maximum outgassing volume: ≥ 4L / min Maximum outlet pressure: ≥ 12kpa (90mmHg) Cycle time: 5-6 min Number of alternate trachea: 18-22 tubes Arrangement: ...
... three-chamber system changes the contact area of the patient at regular intervals to avoid pressure loads. The alternating pressure mattress specially adapted to the RotoFlex® reduces the selective contact pressure and ...
Thickness: 15 cm
Weight capacity: 130 kg
... greatly contributes towards simplifying the decontamination process. The mattress has a sandwich construction where the 4cm safety mattress should be inserted. The AGIX3 pump unit is extremely easy ...
AGIX Corporation
Thickness: 6.5 cm
Weight capacity: 130 kg
... The device is composed of a pump with a regulator and a overlay mattress bubble. Designed for home therapy, easy to install, are present in the overlay mattress implications for a better fastening to ...
... PRODUCT DESCRIPTION A True Low Air Loss pressure redistribution support surface system, suitable for both standard and bariatric patients who need to treat and prevent pressure ulcer from stage I to IV. This system is made with the highest ...
Carilex
... 4" Alternating Mattress System • Cover: Nylon TPU Cover with Push Button • Cell: TPU Cell 70d • Mattress Size: 4" Height • Water Resistance Mattress Cover and Cell • Power 110V/220V • Dial Adjustable ...
Sigma-Care Development
Weight capacity: 450 kg
... Mattress replacement (MR) installed directly on the bedframe, including static air (Cell-on-cell) or using a foam layer. Overlay mattress (OL) installed on a foam mattress. ...
Thickness: 9 in
Weight capacity: 650 lb
... The Power-Turn™ Elite Lateral Rotation Mattress System combines two clinically effective therapies: Lateral Rotation and True Low Air Loss in a portable system. Power-Turn™ utilizes 18 independent 9″ deep air ...
Blue Chip Medical Product
Weight capacity: 130 kg
... • Size: 2000(L)x860(W)x95(H)mm • Cell height:95mm • Pump power supply:110V/220 • Pressure ulcer stage: I/II • Air input 7-8L/min ...
... Microclimate therapy activation.
... side of the mattress offer added support and ensure that the mattress maintains its functionality and comfort during decompression procedures. ✔ Quick Inflation & Deflation – The included STX 597 one-piece plastic belt ...
Weight capacity: 120 kg
... emergent CPR, please pull the CPR yellow strip outside quickly to reduce the air fast. Air ventilation function Tubes on A-B lines provide alternating inflating CPR - Fast Air Release Valve Made ...
... The air pump adopts electromagnetic vibration type: It has the characteristics of high efficiency, low consumption, low noise and long-term stable operation, and is currently the product for the treatment of patients ...
... every 2 hours. Air mattresses cycle every 10 minutes, equal to 6 turns per hours. 24 independent air bags are removable: Easy to clean, reduce bacteria and facilitate maintenance and replacement. The alternating air ...
Thickness: 0.4 mm
Weight capacity: 150 kg
... Specifications PUMP: Size: 30x13.5xh 11 cm Cycle time: 12 min Operating voltage: 220-240 V, 50 Hz Working pressure: 55-120 mmHg Case material: Flame retardant ABS Air output: 7-8 liter/min TUV-CE IEC/EN60601-1; ...