- Laboratory >
- Laboratory medicine >
- Nasopharyngeal test kit
Nasopharyngeal test kits
... MOLgen SARS-CoV-2 Real Time RT-PCR Kit is a multiplex one-step RT-PCR assay for the qualitative detection of Novel Coronavirus (SARS-CoV-2), by Reverse Transcription (RT) and Real Time Polymerase Chain Reaction (PCR) from RNA extracted ...
ADALTIS
Result display time: 40 min
... oropharyngeal swabs and nasopharyngeal swab samples. It should not be used for screening of the general population and should be used by professionals in professional laboratories. Characteristics Specification 12 tests/ kit Instrument Full-Automatic ...
Result display time: 10 min
Sample volume: 0.1 ml
... temperature ranging from 39.5 to 41 degrees Celsius. The CDV kit can determine the presence of CDV antigen in dogs by binding to specific viral antigens. Features In addition, the test kit is stable ...
... throat, muscle pains, headache, coughing as well as sneezing etc. This test kit helps to diagnose Influenza Type A and B nucleoproteins antigens from nasal swab or nasopharyngeal swab obtained from patient ...
... Intended use: Detection of SARS-CoV-2 specifie RNA Test principle: Real-time reverse transcription polymerase chain reaction and fluorescent probe-primer Sample: Nasopharyngeal swabs(NPS) and sputum Store temperature: ...
Result display time: 15 min - 15 min
Specificity: 99.3 %
Sensitivity: 94.7 %
... Transmission through respiratory droplets is the main route of transmission, which can also be transmitted through contact. This kit is intended to be used for in-vitro qualitative detection of SARS-CoV-2 antigens in human naso-/oropharyngeal ...
Shenzhen Zijian Biotechnology Co., Ltd.
Result display time: 15 min
Specificity: 96, 94.8 %
Sensitivity: 92.3, 94 %
... Immunochromatography test for the detection of respiratory Adenovirus antigens in nasopharyngeal specimens (swab, aspirate and wash). Advantage Sensitive and specific Easy to use and easy to read Minimal sample ...
Coris BioConcept
... reference - 100% Coincidence with an internal negative reference - 100% Limit of detection - 500 copies/mL Sample type - Nasopharyngeal swabs, throat swabs, sputum specim Certificate For Research Use Only. Waiting for the clearance ...
Jiangsu Bioperfectus Technologies Co., Ltd.
... automation-ready-to-use kit for pathogen DNA and RNA extraction from a variety of sample materials like serum, plasma, oropharyngeal/ nasopharyngeal swabs, or any other respiratory samples. It is based on the proven, market-leading ...
... This reagent is used for in vitro qualitative detection of antigen to respiratory syncytial virus (RSV) in human oropharyngeal swab and nasopharyngeal swab samples, and it’s suitable for auxiliary diagnosis of respiratory ...
Shenzhen Afkmed
... buffer 1pc, in individual packing Intended use: Antigen Detection Kit is a lateral flow immunoassay intended for the qualitative detection of the Nucleocapsid antigen from virus in nasopharyngeal ...
Beijing OriginGene-Tech Biotechnology Co.,Ltd
... Package Insert--1pc; Collection Tubes--5pcs; Drop Tips--5pcs; Extraction Reagents--5pcs; Work Station--1pc; Packing: 5 tests/box;1200sets/carton; Box: 19x7x3.8cm; Carton: 59x40x58cm Weight: 20.3kgs/carton Nasal swab using ...
Result display time: 15 min
... Sample volume - 3 drops Storage temperature - Test Cassette : 2-30°C (36-86°F) Detection Buffer : 2-30°C (36-86°F) Shelf life - 18 months Quality control material - Internal quality control reagent ...
Sugentech, Inc.
... The Flu A/B & RSV Combo Test is a colored chromatographic immunoassay for the simultaneous qualitative detection of nucleoprotein antigen of Influenza type A, Influenza type B, and Respiratory Syncytial Virus from nasopharyngeal ...
Vitrosens Biotechnology Ltd.
Result display time: 60 min - 90 min
... The kit is used for qualitative detection of MERS coronavirus nucleic acid in the nasopharyngeal swabs and serum samples of patients infected with Middle East Respiratory Syndrome (MERS) coronavirus. Epidemiology Middle ...
Jiangsu Macro micro-test Medical Technology
Result display time: 15 min
Specificity: 99.6 %
Sensitivity: 97.1 %
... An in vitro multiplexreal-time RT-PCR test for quantitative detection of nucleic acid fromSARS-CoV-2 in oropharyngeal swab, nasopharyngeal swab or deep cough sputumspecimens. --- Single-well, triple target assay covering ...
Sample volume: 0.1 ml - 0.4 ml
... The Universal DNA/RNA Extraction Kit is based on magnetic beads. This kit is intended for DNA/RNA extraction, enrichment, purification from whole blood, serum, plasma, nasopharyngeal swab, oropharyngeal ...
Nanjing Vazyme Medical Technology Co.,Ltd
Specificity: 100 %
... qPCR assay system is a RealTime PCR that enables the direct amplification of COVID-19 infection in human samples like nasopharyngeal swabs (NPS), nasal swabs, nasal wash or aspirate or bronchoalveolar lavage (BAL) using one-step RT-qPCR ...
Result display time: 15 min
Specificity: 99.2, 99.4, 99.5 %
Sensitivity: 97.6, 94.4, 97.8 %
... Diagnostic tests available for detection of influenza viruses in respiratory specimens. INTENDED USE Turklab’s Infuenza A/B Test is a rapid, immunochroma- tographic assay for the qualitative detection of Influenza ...
... ready-to-use PCR kit is available in lyophilized format (freeze-drying process) for long-term storage. The kit can be transported and stored at room temperature and is stable for one year. Each tube of premix contains ...
Nanjing Liming Bio-products Co., Ltd.
Result display time: 100 min - 119 min
Specificity: 99 %
Sensitivity: 100 %
... High volume manufacturing capabilities – Meet global test demands >10,000 tests/hour The kit is intended to use viral RNA samples that have been pre-extracted from specimens such as nasopharyngeal ...
Result display time: 15 min - 25 min
... 30 ℃, and use within 3 months after opening. Samples: nasopharyngeal swab, oropharyngeal swab and anterior nasal swab Package specification: 5 Tests / kit, 25 Tests / kit, ...
... Respiratory Panel RT-qPCR Detection kit allows for RT-qPCR analysis of the samples obtained by Nasopharyngeal and Oropharyngeal swabs. RNA extraction from VTM can be accomplished using any commercial ...
Result display time: 10 s - 900 s
Sample volume: 0.2 ml
... This kit is used for the qualitative detection of nucleic acid from new coronavirus in nasopharyngeal swabs, oropharyngeal (throat) swabs, anterior nasal swabs, mid-turbinate swabs, nasal washes and nasal aspirates from ...
... Covid 19 Antigen Testing. BIOCARD Pro COVID-19 Rapid Antigen kit is a chromatographic immunoassay for the qualitative detection of specific antigens to COVID-19 present in human nasopharyngeal swab ...
Trivitron Healthcare
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group