- Laboratory >
- Laboratory medicine >
- Urine sample reagent
Urine sample reagents
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Storage temperature: 2 °C - 8 °C
... target values and ranges are provided for 18 commonly tested urine chemistry parameters. Features & Benefits Liquid ready-to-use 100% Human Urine Assayed target values provided for 18 parameters Analytes Amylase, ...
Randox Laboratories
Storage temperature: 2 °C - 8 °C
... target values and ranges are provided for 18 commonly tested urine chemistry parameters. Features & Benefits Liquid ready-to-use 100% Human Urine Assayed target values provided for 18 parameters Analytes Amylase, ...
Randox Laboratories
Storage temperature: 2 °C - 8 °C
... of urine test strip analysis. The control is available in convenient 12ml vials with assayed ranges provided for 13 parameters covering the chemical examination of urine specimens. Features & Benefits Liquid ready-to-use 100% ...
Randox Laboratories
... Automated purification of 1–12 samples on the QIAcube Connect Product Details QIAamp DNA Kits provide silica-membrane-based nucleic acid purification from tissues, swabs, CSF, blood, body fluids or washed cells from urine. ...
Albumin, a major plasma protein, is synthesized in the liver from amino acids which are absorbed from the ileum. Its function includes regulation and distribution of extracellular fluid, transportation of various hormones, vitamins and trace metals.Increased ...
ERBA Diagnostics Mannheim
... Free Light Chains (FLCs) are immunoglobulin light chains which are circulating in serum in a free state (unbound). There are two types of immunoglobulin light chain produced in humans, designated kappa (κ) and lambda (λ). The quantification of serum ...
... upon request. Separated multiparametric calibrator and controls are available for purchase. Quantite Reagent 1: 2x50 mL Reagent 2: 2x18 mL ...
Purity: 95 %
... recipients. STAT-NAT® BKV kit proved its effectiveness for the detection and quantification of BKV DNA in urine, plasma and whole blood samples. The high-sensitivity and specificity, linearity and quantitation performances ...
... Intended Use This reagent is intended for in vitro quantitative determination of microalbumin in human urine -Nephelometry methodology -Linear up to 200 mg/L -Ready to use reagents -No need to dilute ...
... Clinical Chemistry Reagents 1. Lyophilized 2. Liquid Stabe 3. Chemicals 4. System Reagents Immuno Chemistry Reagents 1. SensIT 2. System Reagents for Mispa i2, Mispa i3 etc Blood ...
... (Negative)
Packaging ...
Storage temperature: 15 °C - 25 °C
... Determinations of total protein level in urine and CSF are used to diagnose and monitor clinical conditions associated with abnormal proteins concentrations. Increased total protein level in urine can be observed in majority ...
... suspension cultures, cotton swabs, sputum, urine and stool samples. Realizes the high-throughput processing of parallel samples. The whole operation process is safe, convenient and no need for organic ...
Storage temperature: 15, 30, 2, 8 °C
β-Lactamase production (ESBL, AmpC, carbapenemase) is the most common mechanism of β-lactam drug resistance in Gram negative bacteria. Each of the involved mechanisms can be plasmid-encoded and transfer horizontally. Moreover, plasmids continuously gather ...
CHROMagar
Storage temperature: 15 °C - 30 °C
... suggested that each laboratory establish its own range of expected values. Reagent Deterioration: The reagent should be discarded if: (1) Turbidity has occurred; (2) The reagent fails to meet linearity ...
Teco Diagnostics
... present in cancer, using not only a small quantity of tissues, but also blood plasma and urine. As its analysis can be performed with a small quantity of blood or urine alone, it can conduct safer and regular gene mutation ...
SEASUN BIOMATERIALS INC.
... Large sample volume up to 30ml Applicable to any aNAP platform Higher efficiency and higher yields ...
... It is the ideal complement to assess the proper functioning of our instruments, or other brands. Diestro Control: to control Diestro analyzers in all models and versions, and also other brands. It includes blood gas parameters. Only for one use. ...
JS Medicina Electronica
... Product for use in the quantitative determination in vitro of the concentration of Magnesium in human serum, plasma and urine. The results of the test must always be interpreted in conjunction with the clinical picture. For professional ...
Storage temperature: 2 °C - 8 °C
... specimen collection and inoculation at point-of-care Saves time, material cost and waste, reducing exposure to collected sample Place directly on the microscope tray for observation through the cassette’s clear anti-fog window Visual ...
... evaluate the inflammatory status of urinary and prostatic tract What Evaluates: the peroxidised compounds in urine Matrix: fresh urine Sector of application: Human and Veterinary IVD/FRUO: For research ...
... 25 mIU/ml hCG Positive 250 mIU/ml hCG Positive Negative (0 mIU/ml hCG ...
Calcium has numerous functions within the body, not only as a structural factor in bones and teeth, but also in normal neuromuscular function and the clotting of blood. The calcium content of an adult is somewhat over 1.0 kg i.e. about 2% of the body ...
Vitro Scient
... Alcohol can be measured in both Clinical & Research and Industrial & Biotechnology applications. Industry & Biotechnology Alcohol can be measured in these areas: Biotechnology & pharmaceutical applications Food & beverage applications Toiletry ...
... screening. The various application is suitable for best decision of doctors, cytologist and patients. URINE - Specimen Collecting: Vioded Urine, Bladder Washing - Application: Bladder Cancer, Kidney Cancer, ...
... Kit for rapid extraction of viral and bacterial DNA from swabs and urine. The kit includes: Solution for fast lysis Solution for dilution of the lysate ...
... therapies Quantification of Cell Death and Cell Death kinetics thanks to a simple reagent, without needing any purification nor amplification, and without needing to sample nor damage the cells. This technology is ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group