OverviewThe SM-5 VelaShap is a portable clinical body‑contouring device that integrates bipolar radiofrequency (RF), 940 nm infrared laser, vacuum negative pressure and mechanical roller massage to reduce localized fat, smooth cellulite and improve skin laxity in clinics and medical spas.
Working principleSynchronized RF and infrared heat penetrate the dermis and subcutaneous tissue to stimulate collagen remodeling and tighten skin. Vacuum negative pressure lifts and mobilizes tissue to enhance microcirculation and lymphatic drainage. Mechanical rollers mobilize adipose tissue and disrupt fibrous septae to improve surface texture. The combined modalities enable non‑surgical contouring with minimal downtime.
Key clinical indications- Cellulite reduction and smoothing of skin surface.
- Body contouring for abdomen, thighs, buttocks, arms and flanks.
- Improvement of skin laxity and stimulation of collagen renewal.
- Adjunctive lymphatic drainage and local metabolic support.
- Postpartum body reshaping and localized adipose reduction.
Clinical advantages- Four‑in‑one platform reduces the need for multiple devices and optimizes clinic ROI.
- Non‑invasive protocol: no injections, no surgical wounds, no general anesthesia.
- Adjustable parameters for different skin types and anatomical zones.
- Comfortable procedure combining gentle suction and roller massage.
- High patient acceptance and easy integration into treatment menus.
Training & supportSEAHEART provides device commissioning, clinical training and after‑sales technical support to ensure safe operation and reproducible outcomes in professional settings.
Technical specifications- Item No.: SM-5
- Working mode: Pulse
- Pulse width: 0.5 s – 7.5 s
- Negative pressure: absolute 80 kPa – 10 kPa (60.8 – 7.6 cmHg); relative 20 kPa – 90 kPa (15.2 – 68.4 cmHg)
- Roller rev: 0 – 36 rpm
- Roller modes: 4 types
- RF frequency: 1 – 5 MHz
- RF energy density: Max 60 J/cm
- Laser wavelength: 940 nm
- Laser power: Max 20 W
- Number of handpieces: 4
- Treatment area sizes: 4 mm x 7 mm, 8 mm x 25 mm, 30 mm x 50 mm, 40 mm x 60 mm
- Rated input power: 750 VA
- Machine size: 625 mm x 525 mm x 1070 mm
FAQs- Is the SM-5 safe for all skin types? Yes. Energy settings are adjustable to match skin phototypes and anatomical areas.
- How many sessions are required to see results? Visible improvement is commonly reported after 3–5 sessions; a full plan is recommended for lasting outcomes.
- Which areas can be treated? Abdomen, thighs, buttocks, arms, waist and back.
- Is the treatment painful? No. Most patients describe a warm, deep‑tissue massage sensation with minimal discomfort.
Clinical feedback- Deane: Easy to integrate into our clinic; patients report comfortable sessions and visible improvement.
- Aaron: The four‑technology combination provides consistent results across body areas.
- Ody: Reliable device with responsive supplier support.