video corpo
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Laboratory freezer ULF86-P series
upright1-doormanual defrost

laboratory freezer
laboratory freezer
laboratory freezer
laboratory freezer
Add to favorites
Compare this product
 

Characteristics

Applications
laboratory
Configuration
upright
Number of doors
1-door
Defrost mode
manual defrost
Other characteristics
ultra-low-temperature
Capacity

408 l, 588 l, 728 l, 838 l
(107.78 gal, 155.33 gal, 192.32 gal, 221.38 gal)

Temperature range

Min.: -86 °C
(-122.8 °F)

Max.: -40 °C
(-40 °F)

Height

1,945.5 mm, 1,994.5 mm
(76.6 in, 78.5 in)

Depth

975 mm, 992 mm, 1,135 mm, 1,155 mm
(38.4 in, 39.1 in, 44.7 in, 45.5 in)

Width

891 mm, 1,179 mm, 1,248 mm
(35.1 in, 46.4 in, 49.1 in)

24-hour power consumption

13.8 kW, 16.23 kW, 19.98 kW, 23.44 kW

Number of decibels

53 dB, 55 dB

Weight

285 kg, 303 kg, 380 kg, 391 kg
(628.3 lb, 668 lb, 837.8 lb, 862 lb)

Description

Key Design Features Microprocessor-controlled system designed for controlled rage of -86℃ to -40℃ for cabinet space with 1℃ increment. Settable high temperature and low temperature alarms. Automatic clean-filter alarm and sensor error alert. Adjustable storage shelf height. Optional temperature recorder, storage racks and storage box. Double security with two independent cooling system, when one system breakdown, the other system could maintain the inner temperature at -70℃. Safety Multifunction alarms including high and low temperature, power failure, sensor error, clean-filter, and extremely high ambient, abnormal voltage, thermostat failure, low battery, condenser clean, door ajar. Capable of producing two types of alarm outputs, audible buzzer and visible flashing light. Door open feature standard and USB port for temperature date downloading standard on upright models. Remote alarm contacts. Installation and Application Wide rage operating voltage system from 187V to 242V designed to allow units installed in areas with poor voltage condition. Suitable for 10℃ to 32℃ ambient temperature. Filed Proven Reliability Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber. Specialized control system design for a well-balanced operation of cascade(dual) refrigeration system. Positive filed proven reliability record. Energy Saving Unique door seal design for the minimum loss of cold temperature during a door opening. High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.