Ablation electrosurgical unit AniSurg™ BRA-55
veterinary surgeryradiofrequency

Ablation electrosurgical unit - AniSurg™ BRA-55 - BMV - veterinary surgery / radiofrequency
Ablation electrosurgical unit - AniSurg™ BRA-55 - BMV - veterinary surgery / radiofrequency
Ablation electrosurgical unit - AniSurg™ BRA-55 - BMV - veterinary surgery / radiofrequency - image - 2
Ablation electrosurgical unit - AniSurg™ BRA-55 - BMV - veterinary surgery / radiofrequency - image - 3
Add to favorites
Compare this product
 

Characteristics

Features
ablation
Medical procedure
veterinary surgery
Technology
radiofrequency
Coagulating power

Max.: 100 W

Frequency

Max.: 450 MHz

Description

AniSurg™ BRA-55 VETERINARY RADIOFREOUENCY TUMOR ABLATION SYSTEM World's First Bivariate Feedback Control Algorithm Bi-variate Feedback Radio frequency ablation needles and temperature probes can collect tumor impedance and temperature in real time and provide dynamic feedback on the state of the tumor tissue, which can achieve precise control of the temperature at the boundary oftumor ablation and prevent excessive ablations on healthy tissues around the tumor and the formation of eschars inside the tumor, so as to reach the goal of precise ablation. Intelligent Control Algorithms The feedback control algorithm can intelligently recognize and judge the collected real-time impedance and temperature. Through this intelligent ablation mode, we can realize the fully automatic adjustment of ablation power and ablation time during the whole process, without the need for doctors to manually set the ablation parameters before the operation. Product introduction Protection against harmful liquid: RAF-100 Generator:IPX1 Main power input: Voltage:220VFrequency:50Hz ,Power:300VA Output:Voltage :250v (peak),Power:100 W (peak),Frequency: 450 khz Range of Ablation: One Single needle's length is not more than 4cm Operating conditions:Temperature:10C to 30°C Humidity: 30-70%,no condensation Atmospheric pressure range: 70KPa-106KPa Transportation and storage: conditions - The products should be prevented from heavy pressure, collision, direct sunlight and snow and rain, and should be stored in a dry, clean, non-corrosive gas and wellventilated room. Temperature:-20°C to +55°C Humidity: 10-93%,no condensation Atmospheric pressure range: 70KPa-106KPa

Catalogs

No catalogs are available for this product.

See all of BMV‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.