Low-retention pipette tip epT.I.P.S.® LoRetention
filter

low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
low-retention pipette tip
Add to favorites
Compare this product
 

Characteristics

Other characteristics
filter, low-retention

Description

epT.I.P.S. LoRetention pipette tips and ep Dualfilter T.I.P.S. LoRetention filter tips are particularly well-suited for applications with samples that contain detergents. Detergents or detergent containing liquids lower the liquid’s surface tension. This leads to a phenomenon called “wetting”: Residual liquid sticks to the tip wall and cannot be recovered. The invisible film left behind in standard tips shows a significantly high amount of valuable sample material which becomes discarded together with the tip. Particularly when it comes to sensitive PCR and real-time PCR applications or NGS library preparation, low retention surfaces can increase the reproducibility and significantly reduce the loss of expensive reagents. The low retention property of epT.I.P.S. LoRetention pipette tips and ep Dualfilter T.I.P.S. LoRetention filter tips is generated by an ultrahydrophobic, extremely homogeneous surface. It is achieved through an innovative treatment at the molecular level – the “Pearl Effect” Technology. All pipette tips are uncoated, free of additives and do not leach into the sample. Liquids containing detergents simply roll off, so that practically no liquid remains in the tip. These outstanding material properties ensure maximized sample recovery for cost saving and improved reproducibility. Maximum reproducibility with epT.I.P.S. LoRetention and ep Dualfilter T.I.P.S LoRetention In particular with sensitive PCR and real-time PCR applications low retention surfaces can increase reproducibility and notably reduce the loss of expensive reagents – depending on the reagent solution, this can be by up to 5 %!

VIDEO

Catalogs

Catalog 2023
Catalog 2023
358 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

ANALYTICA 2024
ANALYTICA 2024

9-12 Apr 2024 München (Germany) Hall B1.301 - Stand Vide

  • More information
    Analytica China 2024
    Analytica China 2024

    18-20 Nov 2024 Shanghai (China)

  • More information

    Other Eppendorf SE products

    Laboratory Consumables

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.