Coagulation electrosurgical unit W400
cuttingplastic surgeryradiofrequency

Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency
Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency
Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency - image - 2
Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency - image - 3
Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency - image - 4
Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency - image - 5
Coagulation electrosurgical unit - W400 - ESC Medicams - cutting / plastic surgery / radiofrequency - image - 6
Add to favorites
Compare this product
 

Characteristics

Features
cutting, coagulation
Medical procedure
plastic surgery
Technology
radiofrequency
Cutting power

Min.: 200 W

Max.: 400 W

Coagulating power

Min.: 120 W

Max.: 150 W

Frequency

480 kHz

Description

ESC Medicams Electrosurgical unit is microprocessor based cautery machine with outstanding performance in monopolar and bipolar procedures. It has spray coagulation which rivals the best spark gap generators and with minimal cutting effect. The Blend gives smooth hemostasis effect than cutting and pure cut is exceptionally smooth and starts promoptly even in irrigated procedures. It meets surgeon's need in wide range of application like urology, gyneacology, Neurology, Plastic Surgery, Laparoscopy. Technical Specifications - Use in Monopolar & Bipolar TURP Procedures - 4 Modes in CUT - Pure,Blend1,Blend2,Endocut - 4 Modes in COAG - Spray,Force,Fulgurate,Desicate - 4 Modes in BIPOLAR- Micro,Macro,Cut,Auto-Mode - Microprocessor controlled Electrosurgical unit - Bode protected and cardiac protected design - Patient Plate Fault Monitoring system - Handswitch and Footswitch Operation - High Frequency - 400W - Minimum RF Distortion - User settable program modes - HF Leakage current > 150mA - Use with Saline Water (0.9% NACL) - Advanced Procedure for TURP

Catalogs

No catalogs are available for this product.

See all of ESC Medicams‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.