Disinfection lamp Unit - 15S
germicidalsterilizationmedical

disinfection lamp
disinfection lamp
disinfection lamp
disinfection lamp
disinfection lamp
disinfection lamp
disinfection lamp
Add to favorites
Compare this product
 

Characteristics

Other characteristics
disinfection, germicidal, sterilization
Applications
medical
Light source
UVC
Configuration
wall-mounted, on casters
Power

40 W

Weight

10 kg
(22 lb)

Height

685 mm, 1,275 mm
(27 in, 50.2 in)

Width

130 mm, 535 mm
(5.1 in, 21.1 in)

Depth

140 mm, 475 mm
(5.5 in, 18.7 in)

Description

The recirculator for 2 lamps with performance of 50 m³/h can be used in the presence of people to disinfect premises of type II, III, IV, V. Description This recirculator is suitable for air disinfection of type II, III, IV, V premises with volume of up to 50 cubic meters. Air is cleaned during forced circulation through a metal body, where two 15 W germicidal lamps impact on the flow. Closed-type apparatus is convenient in maintenance and operation, and disinfection by standard means is possible. Wall-mounted recirculator weighs 5.5 kg and has dimensions of 140x130x685; it is suspended on the wall at a distance of at least a meter from the floor. It has a noise level of no more than 40 dB and electrical safety class MAIN PERFORMANCE VALUES 1. The recirculator operates from AC voltage 220 ±22 V, frequency 50 Hz. 3. Exposure rate from two UV radiation sources (with an open box) at a distance of 1 meter in the effective spectral range of 253.7 nm shall be no less than 1 W/m for РБ-18-"Я-ФП"-02. The lamps of the following manufacturers are variably used as a source of germicidal radiation: - TUV 15W/G15 LL of PHILIPS, - LTC 15 T8 of LightTech, - HNS 15W OFR of OSRAM, Special glass with high transmittance of germicidal UV rays, and at the same time absorbing radiation below 200 nm forming ozone from air is used for the manufacture of lamps. Due to this, an extremely small ozone formation is registered (within MPC), which disappears completely after about 100 hours of lamp operation. The lamp average service life with proper operation and care is at least 9000 hours. 4. The recirculator continuous operation is no more than 7 days.

Catalogs

No catalogs are available for this product.

See all of Ferroplast Medical‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.