washing tunnel / sterilization

Add to MyMedicalExpo favorites
Compare this product
washing tunnel / sterilization washing tunnel / sterilization
{{requestButtons}}

Characteristics

  • Options:

    washing, sterilization

Description

Product Description
Hot air sterilisation tunnels continuously depyrogenate pharmaceutical glass objects (e.g. vials, syringes, etc.) after being washed in a washing machine and prior to being fed into a filling machine. The tunnels consist of the inlet zone, the sterilisation zone and the cooling zone with an appropriate pressure cascade between the zones. The electrical control system is integrated to ensure a compact design.
Various tunnel sizes are available, depending on the throughput (mass of glass). All safety-relevant functions are constantly monitored electronically.

Technical Details
Self-supporting stainless steel construction
Recirculation system with sensitive pressure cascade control between the zones
Sterilisation temperature up to 350°C
HEPA filter H14
Integrated PLC control system (Siemens S7-300)
Technical documentation according to the Machinery Directive
Qualification documentation
GMP-/FDA-compliant design
CE declaration of conformity

Options:
Sterilisable cooling zone
Airtight discharge compartment for the isolator connection
15“ touch panel (B&R)
Electronic chart recorder for process data recording