Stereotactic radiation therapy immobilizer RPS Head
stereotactic radiosurgerySRTSRS

Stereotactic radiation therapy immobilizer - RPS Head - gKteso GmbH - stereotactic radiosurgery / SRT / SRS
Stereotactic radiation therapy immobilizer - RPS Head - gKteso GmbH - stereotactic radiosurgery / SRT / SRS
Stereotactic radiation therapy immobilizer - RPS Head - gKteso GmbH - stereotactic radiosurgery / SRT / SRS - image - 2
Add to favorites
Compare this product

Characteristics

Applications
stereotactic radiosurgery, SRS, surface guided radiotherapy, stereotactic radiation therapy, SGRT, SRT
Area of the body
head
Patient type
adult

Description

Overview
The RPS Head is a retrofit angular correction add-on designed for precise patient alignment in head & neck radiotherapy and cranial stereotactic radiosurgery (SRS). It provides manual 6DoF adjustments (pitch, roll, yaw) with sub-degree angular accuracy and submillimeter positional reproducibility, enabling integration with surface‑guided radiotherapy (SGRT) workflows without removing thermoplastic masks or interrupting the treatment sequence.

Key Features
  • Manual 6DoF angular correction at the treatment table (pitch, roll, yaw)
  • Sub-degree angular accuracy and submillimeter positional reproducibility
  • Compatibility with single- and two-piece thermoplastic mask systems and standard indexing boards
  • Retrofit-ready design for installation on existing indexing plates
  • Supports SGRT-based workflows for surface tracking and alignment

Product Highlights
  • Model: RPS Head (angular correction add-on)
  • Mass: 4 kg
  • Angular correction range: ±4° per rotational axis (clinical range; mechanical limits depend on configuration)
  • Patient weight capacity: up to 200 kg
  • Mask compatibility: supports 5+ mask types (examples: Orfit, Qfix, CQ Medical, 3C, IT‑V, Macromedics)

Advantages and clinical benefits
The RPS Head enables controlled angular corrections after mask fixation, preserving mask-based immobilization while improving beam alignment and reproducibility across fractions. This reduces the need for additional imaging and supports improved dose conformity in stereotactic and fractionated treatments.
  • Improved beam alignment through sub-degree angular correction
  • Maintains reproducible geometry across treatment fractions
  • Facilitates SGRT-guided setup verification and correction
  • Retrofit integration minimizes disruption to existing clinical hardware

How you benefit
Provides cost‑efficient, manual 6DoF alignment for ring-mounted and helical platforms (e.g., Halcyon®, TomoTherapy®) and conventional photon systems. The plug‑and‑play retrofit approach streamlines clinical adoption and preserves current mask workflows while improving targeting accuracy and treatment reproducibility.

Applications
  • Stereotactic radiotherapy (SRT / SRS)
  • Surface‑guided radiotherapy (SGRT) workflows
  • TomoTherapy® and other ring/helical photon platforms
  • Head & neck radiotherapy with thermoplastic masks
  • Fractionated brain radiotherapy and metastasis treatments

FAQ / Technical notes
  • The RPS Head uses a precision 6DoF mechanism to permit fine angular adjustments after mask fixation, enabling submillimeter and sub-degree corrections without mask removal.
  • System-independence: compatible with common mask systems and standard indexing boards; many setups require no additional adapters.
  • Angular correction per axis: clinically relevant ±4° range with sub-degree accuracy; see technical datasheet for exact mechanical limits by configuration.
  • Designed and manufactured under ISO 13485 processes; MDR-compliant and FDA cleared where applicable.

Technical specifications
  • Model: RPS Head
  • Weight: 4 kg
  • Angular adjustment range: ±4° (pitch, roll, yaw) with sub-degree accuracy
  • Adjustment capability: submillimeter positional adjustments in rotational axes (manual 6DoF)
  • Patient weight capacity: up to 200 kg
  • Integration: retrofit-ready for standard indexing boards; installation typically requires no major hardware changes
  • Regulatory / quality: MDR-compliant, FDA cleared, ISO 13485 certified
  • Clinical compatibility: supports SGRT and stereotactic workflows; compatible with Halcyon®, TomoTherapy® and other photon therapy systems
  • Purpose: manual angular correction at the treatment table to maintain reproducible geometry and improve dose conformity
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.