Laboratory thermometer BAT-10
veterinaryambientdigital

Laboratory thermometer - BAT-10 - IITC Life Science - veterinary / ambient / digital
Laboratory thermometer - BAT-10 - IITC Life Science - veterinary / ambient / digital
Add to favorites
Compare this product

Characteristics

Applications
laboratory, ambient, veterinary
Display
digital
Technology
thermocouple
Other characteristics
multifunction
Temperature range

Max.: 400 °C
(752 °F)

Min.: -200 °C
(-328 °F)

Description

The new BAT-10 is the most versatile thermometer we have ever designed. Wide temperature range and extensive choice of probes can be used in applications as diverse as cryogenic measurements for blood banking and cryosurgery, skin temperature measurements in exercise experiments, liquid measurements in spectrophotometer cuvettes, melting points of plastics and all types of animal and insect temperature measurements. BAT-10 accuracy is NIST traceable and in each temperature range accuracy is the same as the resolution. For instance, in the 0.1°C range, accuracy is 0.1°C (± 1 least significant digit). Few digital thermometers will do this. In most instruments there is a difference of several tenths between specified accuracy and resolution. At physiological temperatures, where minute changes can be critical, the differential range allows readings to 0.01°C with 0.01°C accuracy. - Features - Multiple inputs - Three ranges - NIST traceable accuracy - Resolution and accuracy as high as 0.01° C - Specifications - Temperature Range and Resolution: -200 °C to +400°C, 1°C resolution; –100°C to +199.9°C, 0.1°C resolution - Differential Temperature Range: –19.99° to +19.99°. Linearization centered at 40°C. 0.01°C resolution. - Accuracy, 1° range: 1°C + 1 least significant digit - 0.1° range: 0.1°C + 1 least significant digit - diff. range: 0.01°C + 1 least significant digit - Repeatability: + one least significant digit - Calibration: Conforms to National Institute of Standards and Technology tables (Monograph 125) - Sensors: Any Physitemp type T thermocouple - Ambient Operating Range: 15 – 45°C - Readout: Liquid crystal, 3 1/2 digits - Batteries: BAT-10 — 4 alkaline “C” cells (battery life, 1000 hours); BAT-10R (rechargeable unit) – 4 Ni-Cads - Analog Output: Non-linearized set at 1.6V corresponding to temperature of 401°C - High Accuracy in all Temperature Ranges - Range: -100 to +200° C - Resolution: 0.1° C - Accuracy: 0.1° C (+ 1 digit) - Range: -200 to +400° C - Resolution: 1° C - Accuracy: 1° C (+ 1 digit) - Differential: 0.01° C - Accuracy: 0.01° C (+ 1 digit) - Multiple inputs - Three temperature ranges - NIST traceable accuracy - Resolution and accuracy up to 0.01°C - Temperature Range: -200°C to +400°C (1°C resolution), –100°C to +199.9°C (0.1°C resolution) - Differential Temperature Range: –19.99° to +19.99° (0.01°C resolution) - Accuracy: 1°C, 0.1°C, or 0.01°C + 1 least significant digit depending on range - Repeatability: + one least significant digit - Calibration: NIST tables (Monograph 125) - Sensors: Any Physitemp type T thermocouple - Ambient Operating Range: 15 – 45°C - Readout: Liquid crystal, 3 1/2 digits - Batteries: 4 alkaline “C” cells (BAT-10), 4 Ni-Cads (BAT-10R) - Analog Output: Non-linearized, 1.6V at 401°C

Catalogs

No catalogs are available for this product.

See all of IITC Life Science‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.