Transform Your Research with Stellar TelemetryElevate your animal research with Stellar Telemetry — a state-of-the-art wireless system engineered to streamline your workflow and enhance data quality. Designed for maximum flexibility and efficiency, Stellar allows you to monitor multiple animals simultaneously with a single receiver, supporting group housing and natural social interaction.Whether you’re working with laboratory mice, rats, livestock, or wildlife, Stellar’s advanced implants are adaptable to a wide range of species and study types — including behavioral analysis, metabolic research, general physiology, and safety assessment.Built and designed with “The three R principle” in mind. Stellar aligns with standards and research best practices — helping you achieve more, with less complexity.Unmatched Flexibility: Study any animal — from mice to wildlife, even farm animals in outdoor pens.Freedom of Movement: Animals can roam freely with real-time or memory-based data collection.Smart Data Capture: Memory-type transmitters collect data even when out of range, then upload once back in range.Compatibility: Seamlessly integrates with popular software platforms – Acknowledge (Biopac), Notocord-hem (Instem), and Spike2 (CED).Effortless Integration: Designed to complement virtually any research setup.Automatic Operation: Devices can be programmed to turn on/off automatically for optimal data capture.Disposable Transmitters: Eliminate downtime: our implants require no returns for refurbishment.Why Researchers Choose Stellar TelemetryUnbeatable Price-to-Value Ratio: Stellar delivers premium features and performance at a fraction of the cost of traditional telemetry systems — finally making advanced research accessible without compromising on quality.Exceptional Service & Support: Our dedicated team, led by engineers with decades of experience, understands your needs and is here to help — from onboarding to troubleshooting, we’re with you every step of the way.Group Housing Compatibility: Unlike many systems that restrict animals to individual housing, Stellar supports group housing — promoting natural behavior and reducing stress for more accurate results.Onboard Memory: Collect data even when animals are out of range. Our smart transmitters store data onboard and sync automatically when within receiver proximity — no interruptions, no lost data.Compatible with Leading Software: Seamless integration with widely-used platforms like Acknowledge (Biopac), Notocord-hem (Instem), and Spike2 (CED) gives you freedom to work with tools you already trust.Ultimate Flexibility: You control the research. With adjustable sample rates, customizable filters, and scalable setup options, Stellar adapts to your study — not the other way around.Solid-State Pressure Sensor: Built with a reliable, compact pressure sensor —High frequency responseNo fluid head pressureEngineered without fragile gel tips for simplified, more reliable insertionPure Digital Data: Experience the clarity and integrity of true digital data — minimizing noise and maximizing data fidelity for confident analysis.Titanium Housing for Maximum Reliability – Memory Implants only at this time: Built to last. Stellar’s titanium-encased transmitters are lightweight, biocompatible, and exceptionally durable, ensuring consistent performance even in demanding environments.Technical Specifications / Features TableFeatureBenefitMemory ImplantsContinuous ImplantsBuilt-in memory | Remote data collectionRemote collection with no data lossYesNoTransmission rangeMinimize antennas, integrate with other research hardware5 metersUp to 3 metersWireless remote programming of implantsProgram while implanted without handling animalsYesYesUser programmable sample rateAdapt to application while maximizing battery life100/200/500/1000Hz1/100/250/500HzContinuous data collectionIdeal for detection of events such as sleep, seizures, arrhythmias, etc.YesYes (optimal use)Scheduled data collectionProlong battery lifeManage data protocolYes (optimal use)YesLong transmission rangeFlexible antenna placementMinimize antennasEasy system integration5 metersUp to 3 metersTransducer-tipped solid state pressure catheterHigh-fidelity recordingsNo fluid head pressureYesYesAvailable sizesAccommodate wide range of animals and battery life2.0-57ccXS,M,L,XL,XXL2.0-7.4ccXS,M,LTarget animal sizeAccommodate wide range of animal sizes22g to unlimited22g to 1.5kgBattery lifeSelect size and protocol for individual study needs30 days to > 1 year*21 days to 4+ monthsPressure RangeAccommodate full range of physiologic pressures-100 to +500mmHg-100 to +500mmHgBiopotential RangeFactory adjustable+/-4mV+/-8mV+/-4mVBiopotential BandwidthFactory adjustable1-100Hz1-200Hz1-400Hz1-100Hz1-200HzTemperature RangeAccommodate full range of physiologic temperatures0-45°C***0-45°CActivityProvide qualitative measurement of movement derived from accelerometerRelative movement (counts/sec)Relative movement (counts/sec)* Scheduled battery life based on 10-second sample every 10 minutes. Varies based on device size, number of channels, sample rate, and data collection protocol.** Pressure frequency response is dependent on requested sample rate.*** Extended temperature range can be accommodated on request.Feature Comparison: Memory vs. Continuous ImplantsFeature / BenefitMemory ImplantsContinuous ImplantsBuilt-in Memory / Remote UseYesNoTransmission RangeUp to 5 metersUp to 3 metersAvailable Sizes1.5–57 cc (XS, M, L, XL, XXL)2.0–7.4 cc (XS, M, L)Target Animal Size22g to unlimited2g to 1.5 kgUser-Selectable Sample Rates100 / 200 / 500 / 1000 Hz1 / 100 / 250 / 500 HzBattery Life30 days to 1+ year*21 days to 4+ months*** Memory implant battery estimate based on a 10-second sample every 10 minutes.** Continuous implant battery life varies based on channel count, size, and sample rate. Continuous implants can offer up to 6× the battery life of memory implants when used for continuous data collection.How to Choose the Right ImplantChoose Memory Implants If:You’re working with larger animals (e.g., dogs, pigs, sheep, NHPs) and need greater transmission distance.Your protocol involves scheduled sampling or remote field studies.You need flexible real-time or memory mode capabilities.You’re starting a new project — memory implants offer the most adaptable entry point.Choose Continuous Implants If:You’re conducting rodent studies requiring long-term continuous recordings (EEG, sleep, seizure, arrhythmia, HRV).You need continuous activity or behavioral tracking over time.Your protocol demands high-resolution, uninterrupted physiological data.Good to Know: With proper software configuration you can switch between implant types across different studies — all while using the same receiver.FAQ HighlightsDifferent sample rates per channel/signal/datatype? Yes. Stellar supports user-selectable sample rates for each channel or signal type.Reuse? Yes. Stellar implants are built for reuse with proper handling. Durable titanium housing and solid-state components make them suitable for multiple uses.Customization? Absolutely. Customization is one of Stellar’s strengths: unique data channels, sensor configurations, housing modifications, or integration with other systems.Sterilization? No, not necessarily. Stellar components are compatible with multiple sterilization methods, including EtO and alternatives.Wild animal monitoring? Yes. Stellar is designed for maximum flexibility and ruggedness, ideal for use in natural environments. Transmitters with onboard memory allow data collection even when animals are out of receiver range.Key Technical Specifications / Features (Summary List)Wireless telemetry system for small animals (mice, rats), livestock, and wildlifeSupports group housing and social interactionMemory and continuous implant optionsTransmission range: up to 5 meters (memory), up to 3 meters (continuous)Battery life: 30 days to 1+ year (memory), 21 days to 4+ months (continuous)Sample rates: 100/200/500/1000Hz (memory), 1/100/250/500Hz (continuous)Pressure range: -100 to +500mmHgTemperature range: 0-45°C (extended range on request)Biopotential range: +/-4mV, +/-8mVBiopotential bandwidth: 1-100Hz, 1-200Hz, 1-400HzActivity monitoring via accelerometerSolid-state pressure sensor, titanium housing (memory implants)Compatible with Biopac Acqknowledge, Instem Notocord-hem, CED Spike2