Characteristics

Class
class II
Applications
laboratory, containment
Configuration
floor-standing
Other characteristics
negative pressure
External width

42.3 in, 54.3 in, 66.3 in, 78.3 in

External depth

31.2 in

External height

61.8 in, 89.3 in, 95.3 in

Description

Purifier Cell Logic+ Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. All models are NSF compliant. These biological safety cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research. During operation, room air is drawn into the inlet grill. The air in the plenum beneath the work surface is a mixture of unfiltered room airand air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area. The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter. Features (All Models) Electronically Commutated Motor (ECM) Constant Airflow Profile (CAP) airflow monitoring system Intrinsically-safe negative pressure design Air-Wave™ Entry System Contain-Air™ Negative Pressure Channel Supply and exhaust 99.99% efficient HEPA filters. 99.999% efficient ULPA filters available

VIDEO

Catalogs

No catalogs are available for this product.

See all of Labconco‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ANALYTICA 2024
ANALYTICA 2024

9-12 Apr 2024 München (Germany) Hall B1.516 - Stand Vide

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.