Product Details
The pH scale typically ranges from 0 to 14. According to the Nernst equation pH values are affected by temperature, hence the temperature compensation is a vital function of any pH Meter to ensure accurate pH measurement.

Specifications
  • pH:
    • Range: -2.000 to 20.000 pH
    • Resolution: 0.1, 0.01, 0.001pH
    • Accuracy: ± 0.002 pH
    • Calibration Points: Up to 6
    • Standard Recognition: NIST, GB, DIN buffers
    • Calibration Reminder: Yes
    • Slope Limit: Yes
  • mV/ORP:
    • Range: -2000.00 to 2000.00 mV
    • Resolution: 0.1, 0.01 mV
    • Accuracy: ± 0.1 mV or ± 0.03 %
  • Temperature:
    • Range: -5 to 130 °C
    • Unit: °C
    • Resolution: 0.1
    • Accuracy: ± 0.1
  • Measurement:
    • Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous
    • Reading Prompts: Reading, Stable, Locked
    • Temp. Compensation: ATC, MTC
  • Data Management:
    • Data Storage: 1000 Groups
    • GLP Features: Yes
    • Log Management: Yes
  • Inputs:
    • pH Electrode: BNC(Q9)
    • Temp./DO Probe: 6-pin MiniDIN
  • Outputs:
    • USB, RS 232: USB 2.0 flash memory device, printer, PC
  • Display Options:
    • Backlight: Yes
    • Auto Shut-down: 1~60 min, off
    • IP Rating: IP54
    • Date and Time: Yes
  • General:
    • Power: AC Adapter, 100-240 V AC input, DC24 V output
    • Dimensions: 280x280x130 mm
    • Weight: 2500 g (5.51 lb)

Caractéristiques / Spécifications techniques
  • Model: MET21-06
  • pH measurement range: -2.000 to 20.000 pH
  • pH resolution: 0.1, 0.01, 0.001pH
  • pH accuracy: ± 0.002 pH
  • Calibration points: Up to 6
  • Standard buffer recognition: NIST, GB, DIN
  • Calibration reminder: Yes
  • Slope limit: Yes
  • mV/ORP range: -2000.00 to 2000.00 mV
  • mV/ORP resolution: 0.1, 0.01 mV
  • mV/ORP accuracy: ± 0.1 mV or ± 0.03 %
  • Temperature range: -5 to 130 °C
  • Temperature resolution: 0.1
  • Temperature accuracy: ± 0.1
  • Reading modes: Auto Read (Fast, Medium, Slow), Timed, Continuous
  • Reading prompts: Reading, Stable, Locked
  • Temperature compensation: ATC, MTC
  • Data storage: 1000 groups
  • GLP features: Yes
  • Log management: Yes
  • pH electrode input: BNC(Q9)
  • Temp./DO probe input: 6-pin MiniDIN
  • Outputs: USB 2.0, RS 232 (flash memory device, printer, PC)
  • Display backlight: Yes
  • Auto shut-down: 1~60 min, off
  • IP rating: IP54
  • Date and time: Yes
  • Power: AC Adapter, 100-240 V AC input, DC24 V output
  • Dimensions: 280x280x130 mm
  • Weight: 2500 g (5.51 lb)

Catalogs

No catalogs are available for this product.

See all of labstac‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.