Automatic clinical chemistry analyzer PKL PPC 125 VET
veterinarybenchtopwith barcode reader

automatic clinical chemistry analyzer
automatic clinical chemistry analyzer
Add to favorites
Compare this product
 

Characteristics

Operation
automatic
Applications
veterinary
Configuration
benchtop
Options
with barcode reader, with STAT port
Throughput

200 p/h

Sample volume

Max.: 0.05 ml
(0.001691 US fl oz)

Min.: 0.002 ml
(0.000068 US fl oz)

Number of sample positions

45 unit

Reagent volume

Max.: 0.4 ml
(0.01 US fl oz)

Min.: 0.01 ml
(0 US fl oz)

Number of reagent positions

40 unit

Weight

30 kg
(66.1 lb)

Length

560 mm
(22 in)

Width

410 mm
(16.1 in)

Height

360 mm
(14.2 in)

Description

24 hour non-stop cooling system to ensure reagent at 2-8 degrees Durable ceramic syringes to ensure accuracy & precision High accurate optical system Collision protection in both vertical and horizontal directions, stop & alarm automatically once touching barrier, not affect former tests Automatic eligible cuvettes detection & selection Select best test point by reaction curve, create new factor automatically Support LIS interface Description Assay methods: End Point, 2 End Point Kinetic, Fix time etc. Principle: Photoelectric colorimetry Light Source: Halogen-Tungsten lamp with long life Photometry range: 0~4 Abs Resolution: 0.0001 Abs Wavelength: 340nm\405nm\450nm\492nm\510nm\546nm\578nm\630nm\700nm\800nm Refrigeration : On board cooling for Reagents , Samples , Calibrators , Standards , Control with ON/OFF Switch. 24 hours non-stop cooling system to ensure reagent at 2-8 degrees Maximum reaction time: 10 minutes Water Consumption: 2L/hour under working status Clean unit: 8-step auto-washing system with detergent Calibration: Calibration reset, select best test point by reaction curve, no need second calibration Line/non-line;multi-standards assay Control rules: Westgard multi-rule, Cumulative sum check, Twin plot 3 level controls for each ifem, analyxing and printing QC analysis diagram Temperature control: incubator 37± 0.1 Power supply: AC 220V, 50Hz Ambient: Operating temperature: 10~30 degrees Relative humidity: <85% Atmospheric pressure: 86~106kPa Support LIS interface
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.