Electric connector CA1
medicalfor medical devicesinsulated

Electric connector - CA1 - Shandong Newheek Image Equipment - medical / for medical devices / insulated
Electric connector - CA1 - Shandong Newheek Image Equipment - medical / for medical devices / insulated
Electric connector - CA1 - Shandong Newheek Image Equipment - medical / for medical devices / insulated - image - 2
Add to favorites
Compare this product

Characteristics

Type
electric
Applications
for medical devices, medical
Other characteristics
straight, elbow, insulated, flat

Description

Product Definitions
  • X‑ray high‑voltage cable socket: Insert installed on the high‑voltage generator and X‑ray tube assembly to provide the high‑voltage connection between components.
  • X‑ray high‑voltage cable plug: Plug unit assembled with high‑voltage cable to connect the high‑voltage generator and X‑ray tube; connector orientation may be straight or bent.


CA1 Type High‑Voltage Socket — Product Overview
This CA1 high‑voltage cable socket is engineered for medical X‑ray equipment to ensure reliable transmission of high‑voltage power between the X‑ray generator and tube assembly, supporting stable operation under high‑voltage/high‑current clinical conditions.

Product Structure
Insert mounted on the high‑voltage generator and X‑ray tube assembly to enable secure high‑voltage connection. Accessories supplied: pressure ring, flat mat.

Installation & Operation Steps
  • Preparation: Power off the X‑ray system before installation. Verify that the socket and surrounding area are clean and dry to avoid contamination or moisture that could compromise insulation.
  • Inserting the plug: Align plug pins with the socket terminals and insert slowly, respecting the wedge‑shaped orientation. Do not force or twist the plug to prevent pin damage; ensure pins make close contact with terminals.
  • Securing the plug: After insertion, fix the plug using the fixing ring or appropriate retention device to prevent loosening during operation.
  • Apply insulation aid: Evenly apply anhydrous petroleum jelly or silicone grease to the plug surface prior to insertion to improve insulation and reduce discharge risk.


Safety Notes
  • Installation environment: Install sockets in dry, well‑ventilated areas, away from flammable, explosive, or corrosive substances. Ensure secure mounting and tight terminal connections to avoid poor contact.
  • Operation procedure: Insert and remove high‑voltage plugs only with power off and following approved procedures to prevent electric shock or equipment damage.
  • Inspection and maintenance: Regularly inspect appearance, terminals and insulation. Replace or repair immediately if damage, looseness, or insulation degradation is detected to maintain safe operation in medical settings.


Commercial Information
  • FOB price range: US $0.5 - 9,999 per piece
  • Minimum order quantity: 100 Piece/Pieces
  • Supply ability: 10,000 Piece/Pieces per Month


Technical specifications
  • Model / Type: CA1
  • Application: High‑voltage connection between X‑ray generator and X‑ray tube assemblies (medical X‑ray equipment)
  • Connection form: Straight or bent connector options
  • Accessories included: Pressure ring, flat mat
  • Operation environment: Dry, well‑ventilated location; avoid flammable, explosive or corrosive substances
  • Recommended maintenance: Regular inspection of appearance, terminals and insulation; replace if damaged or insulation degraded
  • Insulation aid: Apply anhydrous petroleum jelly or silicone grease to improve insulation and reduce discharge risk