Whole body vascular model PLZHXG011
femoral arteryblood vesselscoronary arteries

Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries - image - 2
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries - image - 3
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries - image - 4
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries - image - 5
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries - image - 6
Whole body vascular model - PLZHXG011 - Shanghai Preclinic Medtech Co., Ltd - femoral artery / blood vessels / coronary arteries - image - 7
Add to favorites
Compare this product

Characteristics

Area of the body
femoral artery, abdominal aorta, coronary arteries, subclavian artery, brachial artery, common carotid artery, middle cerebral artery, blood vessels, whole body
Procedure
vascular access
Material
silica gel
Accessories
with blood vessels
Other characteristics
transparent, flexible, with control unit
Length

1,685 mm
(66.3 in)

Width

585 mm
(23 in)

Height

264 mm
(10.4 in)

Description

Product overview
The model features a transparent humanoid shell with vascular anatomy reconstructed from real CT/MRI data. Major arteries are integrated into a modular vascular network made of highly transparent, soft silica‑gel. A closed circulation loop and an integrated control unit with a bionic pulsatile pump simulate temperature, pressure, flow and pulse for realistic arterial flow scenarios. Suitable for medical training, device evaluation, surgical simulation, practical training and R&D.

Main features
  • Modular, freely combinable vascular segments covering the whole body for high configurability; modular design simplifies transport and scenario-specific setup.
  • Multiple vascular access points for intervention and surgical simulation, including femoral, brachial, subclavian and carotid access.
  • Replaceable lesion modules for targeted training in high‑risk vascular regions; easy interchange to reproduce different lesion morphologies and pathologies.
  • Hemodynamic simulation via pump system allowing adjustment of heart rate, blood pressure and cardiac output to replicate varied clinical scenarios.
  • Procedure recording with a simulated DSA system to capture, replay and export operation sequences for review and assessment.
  • Radiation‑free practice option: high‑transparency vessels compatible with radiation‑free simulated DSA setups for X‑ray‑free procedures.
  • Humanoid form factor to support realistic positioning, instrument handling and team‑based procedural training.


System compatibility & imaging
  • Main material: highly transparent soft silica‑gel (hardness: 30A) providing detailed anatomical fidelity.
  • Integrated bionic pulsatile pump and control unit for temperature, pressure, flow and pulse simulation; closed circulation loop ensures continuous simulated blood flow.
  • Compatible with standard interventional instruments (guidewires, catheters, stents) from manufacturers such as Cordis, Boston Scientific, Abbott and Medtronic.
  • Imaging workflows supported: contrast angiography and CT; can be equipped with a simulated DSA system with HD camera for real‑time display and image enhancement.


Customization & training applications
  • 1:1 customization supported from customer CTA/CT data; various replaceable vascular modules available (e.g. MCA, coronary arteries, abdominal aorta) to simulate aneurysms, stenoses and other disease states.
  • Adaptable for neural, coronary and peripheral intervention scenarios, device R&D and regulatory testing, as well as undergraduate/graduate and continuing medical education.
  • Modular layout facilitates on‑site configuration for specific curricula, device validation or comparative studies.


Drawings & documentation
Includes technical drawings and schematic images illustrating modular layout and component interfaces for use in training, device testing and installation reference.

Technical specifications
  • PN: PLZHXG011
  • Main material: highly transparent soft silica‑gel (hardness: 30A)
  • Vascular model dimensions (L × W × H): 168.5 cm × 58.5 cm × 26.4 cm
  • Lead time: 25 days
  • Origin: Shanghai, China

Catalogs

No catalogs are available for this product.

See all of Shanghai Preclinic Medtech Co., Ltd‘s catalogs

Other Shanghai Preclinic Medtech Co., Ltd products

Full Body Vascular Simulation Models

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.