OverviewuMR® 780 is a 3.0T MRI system designed for accelerated clinical and research imaging. It combines a 170 cm short‑magnet architecture, high homogeneity and advanced gradient performance with AI‑enabled acquisition and reconstruction to enable rapid, high‑resolution examinations.
Value proposition- Fast, AI‑driven imaging workflow — accelerated acquisitions and reconstructions enabled by the uAIFI AI platform.
- Consistent high homogeneity and superior gradient performance for a broad range of clinical protocols.
- Optimized for throughput: reduces scan time while maintaining diagnostic image quality.
Key features & benefits- Advanced acceleration techniques: higher acceleration factors for routine MRI sequences.
- Short acquisitions: typical single body‑part protocols achievable in approximately 100 seconds to increase throughput and reduce motion artifacts.
- High resolution in shorter times: improved depiction of small anatomical structures to expand diagnostic capability.
- Motion freezing capability: benefits patients who have difficulty remaining still (elderly, pediatric), improving exam success rates.
High performance system- High‑performance gradients: faster data acquisition and improved scanning efficiency.
- High‑density RF channels: 48‑channel RF architecture and integrated high‑density coils to increase SNR.
- Ultra‑high magnet homogeneity: powerful 3.0T magnet with a 170 cm short‑magnet design for uniform field across a large FOV and consistent fat saturation and off‑center imaging.
Hybrid AI engines — ACS × DeepRecon- ACS integrates AI with multiple acceleration technologies to accelerate acquisitions and mitigate motion effects.
- DeepRecon applies deep learning to image reconstruction to improve SNR, resolution and reconstruction speed.
- The hybrid approach reduces traditional trade‑offs, enhancing scan time, SNR and resolution simultaneously.
Software & platform- uAIFI Platform: end‑to‑end AI application platform powering accelerated acquisition and AI reconstruction workflows.
- Comprehensive clinical and research applications available for advanced anatomical and functional imaging.
Clinical applications (examples)- Time‑of‑Flight (TOF) MR angiography
- Brachial plexus imaging
- Trigeminal nerve imaging
- TMJ imaging
- Ankle high‑detail imaging
- Body and lower extremity CE‑MRA
- High‑speed protocols for motion‑sensitive patients
Technical specifications- Model: uMR® 780
- Magnet field strength: 3.0T
- Magnet design: 170 cm short‑magnet for ultra‑high homogeneity
- RF channels: 48‑channel RF architecture
- Acceleration technologies: ACS (AI‑based acceleration) integrated with multiple acceleration techniques
- Reconstruction: DeepRecon (deep‑learning based reconstruction)
- AI platform: uAIFI Platform for end‑to‑end AI‑powered acquisition and reconstruction
- Performance target: typical body‑part acquisitions achievable within ~100 seconds; acquisitions and reconstructions achievable in seconds
- Intended benefits: increased throughput, motion freezing, higher resolution in shorter scan times, improved SNR, consistent fat suppression over large FOV and robust off‑center imaging