Laboratory medical sterilizer MOST-L
steamon castersautomatic

Laboratory medical sterilizer - MOST-L - Shinva Medical Instrument - steam / on casters / automatic
Laboratory medical sterilizer - MOST-L - Shinva Medical Instrument - steam / on casters / automatic
Laboratory medical sterilizer - MOST-L - Shinva Medical Instrument - steam / on casters / automatic - image - 2
Laboratory medical sterilizer - MOST-L - Shinva Medical Instrument - steam / on casters / automatic - image - 3
Add to favorites
Compare this product

Do you want to buy directly? Visit our shop.

Characteristics

Applications
laboratory
Sterilization procedure
steam
Configuration
on casters
Function
automatic
Options
with horizontal sliding doors
Capacity

65 l, 85 l, 110 l
(17.17 gal, 22.45 gal, 29.06 gal)

Description

The MOST-L Laboratory Series Steam Sterilizers are mainly applied by laboratories in universities, pharmaceutical factories, inspection departments and disease control & prevention centers for sterilization of labware, culture medium, unsealed liquid or preparation and materials that may contact blood or body fluid in scientific research or medical care units. Characteristics Clamshell-type Automatic Door Structure The multipoint synchronously Interaction and pressing technology renders more reliable door sealing, and the one-button door opening saves time and energy. Humanized Operation System Microcomputer automatic control, LCD text display and induction-type buttons facilitates observation of informational parameters of equipment and process messages of sterilization, making the operation simple and convenient. Water Quality Testing Function The system examines water quality within the tank, and would prompt the user in case the water quality becomes off-spec. Rich Program Types 108 programs in three categories (lab program, medical program and custom program) are set so that the user may flexibly have the program parameters defined. Flexible Steam-discharge Control The user may, based on actual demand, change parameters to control the steam-discharge velocity, which includes rapid, slow and zero. No Steam Exhaust throughout the Whole Process The equipment water is stored to achieve internal circulation of water steam. A condensing system is mounted inside to guarantee that no steam is exhausted throughout the whole process, effectively avoiding aerosol generation and lab injury occurrence and thus ensuring the safety.

Exhibitions

Meet this supplier at the following exhibition(s):

Medica 2025
Medica 2025

17-20 Nov 2025 Dusseldorf (Germany) Hall Unsettled - Stand NN

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.