All-in-One Amplicon Solution
The Accel-Amplicon™ EGFR Pathway Panel offers contiguous coverage of EGFR and hotspot coverage of BRAF, KRAS, and NRAS, using a 17-amplicon design to generate multiplex libraries compatible with Illumina sequencing platforms. The Accel-Amplicon EGFR Pathway Panel is compatible with short DNA fragments from both FFPE and cfDNA samples.
This is especially well-suited for research focused on detecting clinically-relevant allele variants in DNA from circulating tumor cells (CTCs). This product is a complete kit that includes all elements necessary for generating ready-to-sequence libraries, including primer pairs and indexed sequencing adapters.
Features:
Single-tube assay
Ready-to-sequence libraries in 2 hours
Inputs as low as 10 ng
Benefits:
Average amplicon size of 136 bp for compatibility with cfDNA and FFPE
Limit of detection as low as 1%
On-target specificity and coverage uniformity > 95%
Leverages the high fidelity performance of the Illumina platform
Complete library generation in a single kit
The Accel-Amplicon EGFR Pathway panel contains 17 amplicons
with an average size of 136 bp that cover hotspots in four key
genes in the EGFR pathway : BRAF, KRAS , NRAS , and contiguous
regions of EGFR
EGFR Pathway Panel Performance with Horizon’s
1% Multiplex I cfDNA Reference Standard
The Accel-Amplicon EGFR Pathway Panel consistently detected
validated variants at the expected frequency in three replicates
from 10 ng of the Horizon Diagnostics Multiplex cfDNA Reference
Product Specifications
Input DNA Required 10-25 ng*
Time Required 2 hours
Number of Amplicons 17
Amplicon Size 107-155 bp (average 136 bp)