Training simulator GCC01
puncturefor intravenous cannulationsurgery

Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery
Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery
Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery - image - 2
Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery - image - 3
Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery - image - 4
Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery - image - 5
Training simulator - GCC01 - Trando 3D Medical Technology - puncture / for intravenous cannulation / surgery - image - 6
Add to favorites
Compare this product

Characteristics

Procedure
training, puncture, for intravenous cannulation
Application
surgery
Simulated pathology / condition
stenosis
Other characteristics
artery

Description

The model contains rectus abdominis, navel, groin, anterior superior iliac spine, iliac crest, replaceable femoral artery vessels, etc. The skin of the model is made of Silicone Shore 0A, the femoral artery vessels are made of Silicone Shore 40A, the model is designed based on real human CT data and produced by adopting 3D printing technology, Ensuring precise structural accuracy, the model aims to replicate the elasticity and softness of the human body to the maximum extent on the precondition of ensuring the accurate anatomical structure. The replaceable femoral artery vessels are embedded within the reserved channels, when connected to our pulsatile pump, the model can realistically simulates the femoral artery pulsing, while conducting puncture procedure, the arterial bleeding can appear. The simulator is also equipped with 10 replaceable healthy femoral artery vessels, as well as 6 replaceable tortuous and 6 stenosis femoral artery vessels. Product Usage: Applicable for simulating femoral artery puncture training. Customization options: 1.Vascular lesions (such as tortuosity, stenosis, calcification, etc.) can be customized. 2.We can customize model based on the data files provided in formats such as CT, CAD, STL, STP, STEP, etc.

Catalogs

No catalogs are available for this product.

See all of Trando 3D Medical Technology‘s catalogs

Other Trando 3D Medical Technology products

Vascular Simulator

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.