Optical spectrometer Omni-λ180Di
RamanUV-Vis-NIRCCD

optical spectrometer
optical spectrometer
optical spectrometer
optical spectrometer
optical spectrometer
optical spectrometer
optical spectrometer
Add to favorites
Compare this product
 

Characteristics

Type
optical, Raman, UV-Vis-NIR
Detector type
CCD
Configuration
benchtop
Wavelength

435.8 nm

Length

559 mm
(22 in)

Width

326.5 mm
(12.9 in)

Height

232 mm
(9.1 in)

Weight

31.5 kg
(69.4 lb)

Description

The Double Monochromators/Spectrographs include two monochromators which are with fine alignment. Double Monochromator can operate as either an additive or subtractive dispersion mode. As the additive dispersion mode, the double monochromator/ spectrograph spectral resolution double boost, suitable for high resolution measurement. As the subtractive dispersion mode, the double monochromator/spectrograph stray light can be reduced effectively, suitable for weaker signal detection, such as Raman spectra measurement. Omni-λ180Di double monochromator Omni-λ180Di is a all-in-one subtractive dispersion mode double monochromator. With the design and optical path adjustment, only the dispersion light converge at the exit slit for output, effectively reducing stray light. Obtaining purer monochromatic light, Omni- λ180Di is used to meet the needs of week signal testing, such as Raman spectroscopy and photodetector spectral responsivity calibration. Features ■ Subtractive dispersion mode double monochromator. ■ Outstanding stray light rejection, less 10-9 ■ All-in-one design, convenient for transportation and installation. ■ USB 2.0 interface, controlled by software ■ UV-VIS-NIR wide spectral range Application ■ Tunable light source: Integrated with broad band light source, Omni-λ180Di can output purer monochromatic light for more accurate test. ■ Raman spectra measurement: When collecting the Raman scatting light, Omni-λ180Di can be used as a narrow band filter to eliminate the excitation laser's effect efficiently for measuring the low shift Raman spectra. ■ Professional detector spectral responsivity calibration: Omni-λ180Di can reduce calibration errors,

Catalogs

No catalogs are available for this product.

See all of Zolix Instruments CO.,LTD‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Analytica China 2024
Analytica China 2024

18-20 Nov 2024 Shanghai (China)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.