Zimmer cementless femoral stems

Femoral stem offset: 7, 6 mm
CCD angle: 132 °
... The tapered design and the glossy finishing avoid load concentration on the femoral cortex thus postoperative thigh pain. MATERIALS The EXACTA RS stems for cementless press-fit ...

Femoral stem length: 137, 177 mm
Femoral stem offset: 37.4, 46.9 mm
CCD angle: 132 °
... Proximally tapered stem geometry converts the shear forces to compressive load. • This helps the stem to resist subsidence and medial migration. Extensive Stress Distribution • Low elastic modulus ...
Corentec

Femoral stem length: 3, 10 mm
Heads connect through 12/14 Eurocone to the stems, sizes are in 28 mm and large ones are also available. Raw material is CoCr or ceramics
Sanatmetal

... old fracture of the femoral neck, pain from destruction of the femoral head or acetabulum, resulting in impairment of joint function; 2. Patients with avascular necrosis of the femoral ...

CCD angle: 135, 125 °
The progressive trapezoidal geometry enables optimal adaptation of the stem and both anti-translational and anti-rotational fixation that provides perfect primary stability while preventing the hip prosthesis from sinking. Specifications Standard ...
Surgival

... adjustment · Co-Cr-Mo Alloy material for stable long-term fixation Indications: · Proximal hip tumor · Complex proximal femur fracture which internal fixation is impossible

CCD angle: 130 °
P130® 2/3 Coated femoral stem for the replacement of the natural hip joint during first intention. Range of products: The metaphyseal profile of the stem ensures the implant’s primary ...
C2F Implants

... the hydroxyapatite coating, ensures stability in the long term. 3 options are offered: - Standard Filler stem - TI Filler stem - Collar Filler stem From 8 to 20 Features Conus: 5°42'30'' ...
Biotechni

... biologic fixation and increasing rotational stability. Stability PROVEN METAPHYSEAL INTEGRATION The proximal design of the stem in the shape of a three-dimensional taper leads to partial filling of the metaphysis ...

Femoral stem length: 115, 150 mm
CCD angle: 135 °
Material: L Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Beznoska

CCD angle: 120 °
... Hype® range of femoral stem is a complete range of self locking stems dedicated to primary total hip arthroplasty. CHARACTERISTICS AND MATERIALS Characteristics : Homothetic size ...
SERF

Femoral stem length: 160, 95 mm
The Entrada Hip Stem integrates a wealth of clinical history—hydroxyapatite coating, compaction broaching, taper wedge geometry—and provides critical refinements—progressive neck lengths, consistent proximal body growth, ...
Ortho Development

The Securus® Revision Stem System, based on the proven Furlong® fully hydroxyapatite ceramic coated (H-A.C.) stem design, with its full interchangeability between proximal bodies and distal stems, ...
JRI Orthopaedics

CCD angle: 135 °
CINEOS® prostheses consist of femoral stems designed for the replacement of the natural hip joint during first intention or during revision surgery. 10 sizes 12/14 taper Without collar Forged Titanium ...
X-NOV Medical Technology

Femoral stem length: 6.25, 20 mm
The concept of this femoral component relies on a dose prosthesis-bone contact in both medial and lateral zones. The stem geometry shows a proximal to distal 3 degree taper providing a greater femoral ...
Biotech Medical

Femoral head diameter: 22.2 mm - 36 mm
CCD angle: 130, 122 °
... to choose between a standard stem (130° neck-shaft angle) and a lateralised stem (122° neck-shaft angle) during the preoperative planning phase or during the procedure itself. Features and materials ...
FH Orthopedics

... stability of the prosthesis, anti-rotation; 3. Microporous titanium coating: Provide good pore space for bone ingrowth; 4. Short stem design: Maximize bone remain and leave bone for revision; 5. Curved distal end patented ...
Beijing Chunli Technology Development

... Titanium alloy •Proximal 1/2 Proven Ti-plasma spray porous coating •Patented neck shape to increase ROM •Proximally tapered stem geometry converts the shear forces to compressive load. •Wide Offset Distribution ...

Femoral stem length: 29, 40 mm
CCD angle: 130 °
Shortened straight stem Titanium + HAP bilayer coating Standard or lateralized neck
Aston Medical
Your suggestions for improvement:
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining