Coronary stents

Do you need help making a decision?  Take a look at our buying guide
43 companies | 115 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
Search
Coronary stents | Choosing the right stent
The main risks associated with inserting stents are restenosis, clotting, kidney risks and vessel rupture. Restenosis: the risk of re-shrinking the artery is very frequent during an angioplasty. Drug eluting stents are the most effective in reducing this risk (see question on the advantage of drug eluting stents). Clotting: thrombosis can form inside the stent after the procedure. The blood clot can then block the artery. This is why it is important...
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
coronary stent
coronary stent
NeoVas™Sirolimus-eluting

Diameter: 2.75, 3, 3.5 mm

Stent Platform *Fully degradable poly(L-lactide) *Sine wave structure in space, In-phase peak-valley connection Drug coating *Fully degradable poly(D,L-lactide) *Effectively control the sirolimus release rate Drug *Classical ...

See the other products
Lepu Medical Technology
coronary stent
coronary stent
Nano+™

Diameter: 2.5, 4 mm
Length: 12, 36 mm

... the distal shaft provides outstanding usability. *Polymer-free design significantly reduces the inflammatory response after stent implantation to guarantee long-term safety. *Polymer-free design facilitates earlier ...

See the other products
Lepu Medical Technology
coronary stent
coronary stent
GuReater®

Diameter: 2.5, 4 mm
Length: 12, 36 mm

... 75μm ultrathin strut guarantees the excellent flexibility of the stent during delivery and helps with better endothelialization. *Low recoil ratio of 3.4% for CoCr stent ensures better stent ...

See the other products
Lepu Medical Technology
coronary stent
coronary stent
Coroflex® ISAR NEO

Coroflex® ISAR NEO Sirolimus eluting polymer-free coronary stent system Coroflex® ISAR NEO is B. Braun´s next generation of Drug Eluting Stents. Thanks to the proven polymer-free ...

coronary stent
coronary stent
Coroflex® Blue Neo

... bare metal stent with ultra thin struts Coroflex® Blue Neo is an innovative coronary stent system for excellent clinical outcome. The extremely flexible stent combines ...

coronary stent
coronary stent
Eurolimus™

Diameter: 2.25, 3, 3.5, 4, 2.75 mm
Length: 8, 16, 28, 38, 43 mm

The EUROLIMUS™ Sirolimus eluting coronary stent system is made of a coated cobalt-chromium alloy (L605) stent and a rapid-exchange catheter. Eurolimus is indicated for use in patients ...

coronary stent
coronary stent
E-Magic™ Plus

Diameter: 2.25, 2.75, 3, 3.5, 4 mm
Length: 8, 16, 24, 32, 40 mm

... eluting coronary stent system is a coronary stent system, made of a coated cobalt-chromium alloy (L605) stent and a rapid-exchange catheter. The E-Magic ...

coronary stent
coronary stent
XLIMUS®

Diameter: 2.25, 2.75, 3, 4, 5 mm
Length: 8, 12, 20, 32, 40 mm

XLIMUS is considered as the ultimate coronary DES stent system to treat complex coronary artery disease by reaching and crossing the most challenging lesions. XLIMUS. Designed for the most ...

coronary stent
coronary stent
Precision®

The new pro healing PRECISION coronary stent system is designed for minimized metal stenting. It is the next generation of cobalt chromium coronary stenting. It minimizes vessel trauma ...

coronary stent
coronary stent
ReNATURAL

... develops an optional bio-absorbable coronary stent, which is made of PLLA and is coated with the same drug Sirolimus to prevent or to treat coronary artery restenosis. Both scientific ...

coronary stent
coronary stent
Cygnus II

... for uncompromising radial strength and radiopacity. Flexible Unique design, a combination of intermediate and open cells stent for outstanding flexibility and optimal vessel support. Track Innovative hydrophilic ...

coronary stent
coronary stent
PK Papyrus

... thin. Low crossing profile PK Papyrus Indicated for acute coronary artery perforations. Stent Stent cover materialNon-woven, electrospun polyurethane Stent ...

See the other products
Biotronik
coronary stent
coronary stent
EVERMINE50

Diameter: 2, 2.75, 3.5, 4.5, 4 mm
Length: 8, 16, 24, 37, 48 mm

... Variable strut width and variable crown design to ensure adequate radial strength of 1.1bar* Hybrid cell stent design: Open cells in the middle of the stent for side-branch access and closed cell design ...

See the other products
Meril Life Sciences
coronary stent
coronary stent
DES - Cre8™EVO

Polymer-free Amphilimus (sirolimus + Fatty acid) eluting coronary stent Product key features: - Polymer-free Abluminal Reservoir Technology - Amphilimus™ formulation: Sirolimus + Fatty Acid - ...

See the other products
Alvimedica
coronary stent
coronary stent
TITAN OPTIMAX

Diameter: 2, 5 mm
Length: 7, 38 mm

... and Very Late Stent thrombosis thus making compulsory prolonged DAPT. BIO ACTIVE STENT BIOMECHANICS Thinner Stent System «Balloon-like» navigability Expanded crossing capabilities Advanced ...

coronary stent
coronary stent
Celosia™

The Direct-Stent Cobalt Chromium has emerged as a champion with its durable, flexible stent design with the proven Direct-Stent platform. The device features. The Cobalt Chromium supports ...

See the other products
InSitu Technologies
coronary stent
coronary stent
COMBO™

COMBO is the world’s first and only dual therapy stent designed to repair vessel injury and regenerate the endothelium, fostering natural, true vessel healing. It does this by accelerating endothelial coverage and controlling ...

See the other products
OrbusNeich
coronary stent
coronary stent
DESyne®

Introducing the Novolimus-eluting DESyne stent - the next generation drug eluting stent with improved performance and superior clinical efficacy and safety1. Engineered on a clinically- proven cobalt ...

See the other products
Elixir Medical
coronary stent
coronary stent
Angiolite

... sirolimus-eluting coronary stent angiolite is made from a cobalt chromium alloy called L605, coated with a mix of sirolimus and last generation of biostable polymers. The stent is pre-mounted ...

See the other products
iVascular
coronary stent
coronary stent
Abrax™

Diameter: 2, 2.5, 3, 3.5, 4 mm
Length: 10, 18, 24, 34, 38 mm

... and stent thrombosis Stent platform Carbon ionized surface for higher biocompatibility and reduced restenosis rateCarbon ionized surface for higher biocompatibility and reduced restenosis rate DATS ...

See the other products
Rontis Medical
coronary stent
coronary stent
SEQUENCE™

SIROLIMUS ELUTING CORONARY STENT SYSTEM The combination of Sirolimus antiproliferative action combined with biodegradable polymer and a proven balloon catheter sets new standards in treatment of clinically ...

coronary stent
coronary stent
BIOSS LIM C

SIROLIMUS ELUTING CORONARY BIFURCATION STENT with RX delivery system lnnovative bifurcation stent system: One profiled balloon with diameters corresponding to dimensions of the ...

See the other products
Balton
coronary stent
coronary stent
Xinsorb®

Diameter: 12, 15, 18, 23, 28 mm
Length: 24 mm

... Scaffold System) is composed of a balloon-expandable absorbable coronary stent, a drug coating and a delivery system. As shown in the figure. Major structures Balloon-expandable absorbable polymer stent Drug ...

See the other products
Shenzhen Wego Healthcare
coronary stent
coronary stent
BIOFREEDOM™ ULTRA

... carrier-free Drug Coated Stent with BA9™ (DCS). BioFreedom™ Ultra is a novel CoCr stent (84µm struts for specific stent diameter (small vessel)), that will optimize the PCI ...

See the other products
Biosensors International
coronary stent
coronary stent
Nile® Pax

BIFURCATION DEDICATED STENT SYSTEM The Complete Solution to Bifurcation Challenge ADAPTED STENT DESIGN - Uniform metal-to-artery ratio - Homogeneous main branch vessel scaffolding 3 segments ...

See the other products
Minvasys
coronary stent
coronary stent
eucaLimus

Diameter: 2.25, 2.75, 3.25, 4, 5 mm
Length: 8, 13, 23, 33, 48 mm

Ultrathin 65 µm Design Excellent Deliverability Degradable Polymermatrix Synchronized Polymerdegradation and Drug Release Wide Range of Sizes 36 Months Shelf Life

See the other products
eucatech
coronary stent
coronary stent
Cygnus II

Coronary - Cygnus II *Thin Extra thin Cobalt Chromium struts 73 µm for uncompromising radial strength and radiopacity *Flexible Unique design, a combination of intermediate and open cells stent ...

coronary stent
coronary stent
Fantom®

... Sirolimus-Eluting Bioresorbable Coronary Scaffold combines the trusted anti-proliferative drug, Sirolimus, with Tyrocore™, REVA’s new proprietary polymer, to make the world’s first radiopaque bioresorbable scaffold for ...

coronary stent
coronary stent
Track

The TRACK Coronary Stent family made of cobalt chromium and optimized for specific area of use. These stent systems provide high end performance with less metal and reliable outcomes. The ...

coronary stent
coronary stent
Coral®

... thinnest Chromium Cobalt Coronary Stent (65µ) available on the market with an innovative Finishing Surface Treatment (FST). Coral® is NATEC Medical coronary stent proposed ...

coronary stent
coronary stent
ProLink SV

Balloon Expandable Coronary Small Vessel Stent 090 mm strut thickness 30 - 0.35 bar radial strength 090 mm strut width 070 mm articulation width

See the other products
Vascular Concepts
exhibit your products

& reach your clients in one place, all year round

Exhibit with us