- Surgery unit >
- Surgical Instruments >
- Electrosurgical unit
Electrosurgical units
Cutting power: 200 W
Coagulating power: 100 W
... NBRIEC 60601-2-2 certified Accessory Kit . 1 transportation unit . 1 footswitch-controlled pencil, fixed cable . 2 disposable pencils . 1 set of special electrodes (3 units) . 1 catheter ...
WEM
... can be transplanted or have a histo-pathological examination up to the incision edges! ** High frequency probes that follow any surgical and anatomical line without pressure, when cutting in the tissue, leaving no ...
... Surgical Generator (SHUYOU DX) Is Designed For The Most Demanding Monopolar And Bipolar Procedures. The SHUYOU DX electrosurgical unit offers optimal performance, accuracy and precision. It has been ...
Shuyou Surgical
Cutting power: 300 W
Coagulating power: 110 W
Frequency: 300 kHz
1) Auto BIPOLAR 2) Spray Coagulation 3) Controlled by Hand & Foot 4) Built-in impedance monitoring system 5) Switching power supply system adopted 6) Simple & compact design for operating room 7) Triple mode- cutting, ...
UNION MEDICAL
Ultrasonic Scalpel System The input voltage:Ac 90V to 240V Input frequency:50 / 60Hz Working current:3A Driving frequency:55.5KHz The power consumption of the largest:300VA Solid interface:Ricks foot FSW01, Johnson GEN300 ...
... satisfy different energy needs. Data Storage Function This function can store the current setting value, and no matter power off or power on, it is not necessary to reset those values in the next discharging. Impedance ...
Cutting power: 120 W
Coagulating power: 70 W
Frequency: 8,000,000, 4 Hz
... at the same time. Besides, the surgeon can perform coagulation, debulk and vaporization of the tissue in any environment (dry or wet). S.M.A.R.T. (Self Monitoring And Recognition Technology) It is an innovative feature ...
Telea Medical
Cutting power: 0 W - 100 W
Coagulating power: 0 W - 100 W
Frequency: 1.7, 4 MHz
Output Voltage: Variable from 500 to 600 ± 20% Application Area: 1. Dermatology / Plastic (Cosmetic) Surgery / RF Mole Removal / Wart, Nevus Skin Tumor 2. Oculoplastics / Trichiasis Surgery 3. Stomatology / Dental / Maxillofacial ...
Beijing Kestrel
... Optional remote temperature probe allows real-time tissue temperature monitoring for extra assurance Measure tissue temperature in or adjacent to ablation zone If desired, automatically stop RF delivery based on the temperature
BNS 1-CH RF Lesion generator, which is a medical device for minimal invasive therapy, has the clinical applications in these fields below: (1) The treatment for the lumbar and leg pain that is caused by prolapse of lumbar intervertebral ...
Beijing Neo Science
Cutting power: 150, 400, 360, 300, 200 W
Coagulating power: 300, 260, 200, 400, 360 W
Frequency: 460 Hz
... saline resection mode SAL – automatic bipolar SEAL mode – easy switching between monopolar and bipolar mode using footswitch or handpiece – heavy duty pneumatic footswitches – low weight, compact design allowing easy ...
Special Medical Technology
Cutting power: 400 W
Coagulating power: 400 W
Touch Screen operation, patient plate conductivity monitoring system (PP-CMS). Accessories contact detection during plug -in and operation. Multiple Modes - 1 Pure cut, 1 Precise Cut, 5 Blend , 3 Endo Cut, 2 Spray, 2 Fulgurate, 1 Dessicate, ...
Enertech Healthcare
The elctrosurgical unit has a maximum power of 50 Watt.The frontal controls are: general main switch,the power adjuster,the rotating commutator for the choice of the required function: cut cut-coagulum or ...
Carlo De Giorgi
-Compact and ergonomic design, quite easy to operate -Patented tissue pad sawtooth design increases cutting efficiency -High efficient output power, less heat radiation and noise -Less thermal damage and more patient consideration -Vessel ...
Frequency: 20 kHz - 32 kHz
SURGYBONE SB 300 A new generation in ultrasound surgery Surgybone aims at satisfying doctors’ everyday need, including the need to exploit room space at best. Thanks to its extreme versatility, selecting the ENDOS programme, the device ...
SILFRADENT SRL
... coag. Maximum safety for the patient and excellent satisfactory result for the operator. The electrosurgical units are supplied complete with accessories: Handpiece, 8 electrodes and ground plate are ...
Cutting power: 350 W
Coagulating power: 150 W
Frequency: 333 kHz
This HF unit system automatically adapts to the user’s needs. Ackermann wanted to create a HF unit that does not requires complicated set-up prior to surgery and is ready for operation directly after ...
Ackermann Instrumente
Cutting power: 55.5 W
Frequency: 55.5 kHz
Faster Cutting Speed The cutting speed of ENGINE‘s scalpel is 10-15% faster than other competitors, and is as fast as JNJ’s cutting speed Integrated Knob Equipped with torque wrench function. Easy to connect the scalpel to transducer Decrease ...
Alfa Medtech
Cutting power: 300 W
Coagulating power: 300 W
... ACCESSORIES TO THE HIGH FREQUENCY ELECTROSURGICAL UNITS: Code Name of product K501-05 Electrosurgical cable for monopolar instruments K501-09 Electrosurgical ...
Electrosurgical unit for monopolar and bipolar surgery Suitable for Bipolar Saline Resection BIMAX 350 is an electrosurgical unit complete, technologically extremely ...
Cutting power: 60 W - 400 W
Coagulating power: 70, 120, 100 W
Frequency: 425, 525 kHz
... recallable procedures. EXTENTION DRIVER AND INTERLOCK SIGNALS Drived output connection to external Argon Plasma unit and Smoke Evacuator unit. AUTOMATIC SELF DIAGNOSIS
EPSIMED
Cutting power: 500, 350, 200, 250 W
Coagulating power: 500, 200 W
... controlled automaticly and by foot. The unit can automaticly switch between monopolar and bipolar. The output power of the unit is digital displayed and its sound level can be adjusted. The malfunction ...
RF Console with Medical Plasma Implementation – Create sophisticated and reliable plasma – Effective surgery in 2 modes (ablation, coagulation) – Output energy options (Level 1 to 9) Certificate CE, MFDS Category Spine
Endovision
Cutting power: 80 W
Coagulating power: 40, 16 W
Frequency: 60, 50 kHz
Cutting mode Available Mixed cutting-coagulation mode Available Coagulation mode Available Bi-polar coagulation mode Available Power activation With footh switch Cutting coagulation impedance 3000 Ω Spray coagulation impedance ...
Elektro-mag
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining