{{{product.idpText}}}

... soft tissues, argon plasma minimises the risk of carbonisation and, as a result of this, procedures are safe and controlled. Due to these advantages, plastic surgeons have opened a new chapter in their ...

Cutting power: 400 W
Coagulating power: 120, 180 W
Frequency: 333 kHz
... modes Monopolar cutting: pure, blend cutting (3 levels), urological cutting, argon cutting, endoscopic cutting Monopolar coagulation: soft, forced, spray, hybrid, argon, argon pulse Bipolar ...

Argon plasma coagulation with the operating convenience of the logical and plausible VIO 3 interface Plug and operate, insert the instrument to immediately begin working with the APC application pulsedAPC ...
Erbe Elektromedizin

The product works for non-contact procedures; instrument tip does not sticks to the tissue. The surface coagulation is effective and even for getting uniform hemostasis and devitalization. Exact dosage of penetration depth guides to safer ...
Erbe Elektromedizin

... Instrument detection: insert the APCapplicator and start working (plug and operate) Sterile single-use product: immediate OR availability, no reprocessing effort required Gas filter is integrated into the connection plug
Erbe Elektromedizin


monopolar coagulation electrosurgical unitEK-250
Cutting power: 120 W - 250 W
Coagulating power: 120 W
Frequency: 425, 525 kHz
FORZA EK-250 electrosurgical device with 250 W maximum output power is the device that can be used in all type of surgeries, like general surgery, orthopedics, urology, cardiovascular surgery, and neurosurgery with high ...

Our argon system is connected to the compatible electrosurgical unit. The endosection power combined with our precise argon beam gives the perfect solution in gastro-enterology ...


monopolar cutting electrosurgical unitDIATERMO MB 300D
Cutting power: 70 W - 300 W
Coagulating power: 70 W - 400 W
Frequency: 50 Hz - 60 Hz
... INTERLOCK SIGNALS - driven output connection to external Argon Plasma unit and Smoke Evacuator unit AUTOMATIC SELF DIAGNOSIS - automatic diagnostic control of the ...

Cutting power: 13 W
Frequency: 50 kHz
... the coagulative necrosis area is greater when using a high frequency electrosurgical scalpel for the incisions rather than when a plasma device is being used. UNIQUE Generates plasma ...

Cutting power: 0 W - 400 W
Coagulating power: 0 W - 150 W
Frequency: 550 kHz - 660 kHz
Alan ELSY 360M+ is a monopolar, bipolar and vessel sealing electrosurgical device designed to use in operating rooms. Technical Specifications - 400 Watt output power - Patient plate warning system - Voice level ...

Cutting power: 0 W - 400 W
Coagulating power: 0 W - 180 W
Frequency: 360 kHz - 550 kHz
Alan Combi Max series are Monopolar, Bipolar, Vessel Sealing, Argon and Plasma Tur electrosurgical devices designed to use in operating rooms. Technical Specifications - 17,5 cm ...

Cutting power: 0 W - 400 W
Coagulating power: 0 W - 250 W
Frequency: 360 kHz - 550 kHz
Alan Combi Max series are Monopolar, Bipolar, Vessel Sealing, Argon and Plasma Tur electrosurgical devices designed to use in operating rooms. Technical Specifications - 17,5 cm ...

... return electrode monitoring technology with an array of specialist modes for desired clinical use. MEDICINOS electro surgical unit intuitive design with user friendly set up features with both monopolar and bio polar ...

Simple versatile safe & reliable designed provides state of the art innovation in an easy-to-use interface. Energia 300VST is simple on the outside yet sophisticated and powerful on the inside. FEATURES AT GLANCE Microprocessor ...

Cutting power: 300 W
Coagulating power: 200 W
... Compact Electrosurgery Unit A design that harbors all the essential components for your OR regimen:Mono-polar and APC unit,with high efficiency and great affordability. APC ...

... supply at first, wherein the capsule after surgery is finishing, the contraction is good, the bleeding or secondary bleeding is less. Advantages of plasma technology in treating bladder cancer: The ...

●Bipolar or multi-polar cutting, low temperature ablation, resection,hemostasis and coagulation, minimally-invasive, safe and reliable way. ●One ABLATION modes (including resection, hemostasis and ablation); One PLACOAG ...

... is a module that can be connected with a compatible electrosurgical unit, specific for coagulation electrosurgical procedures with Argon gas, indicated for both open ...

Cutting power: 400 W
Coagulating power: 200 W
... programs for easily achieving your optimal tissue effect ESD, POEM, ERCP Sphincterotomy, Full Thickness Resection, EMR, Multiple Argon Procedures Cutting and coagulation modes optimized for resection and dissection Customization ...


monopolar cutting electrosurgical unitZEUS-200S
Cutting power: 150, 200 W
Coagulating power: 200, 150 W
... danger of burning. An autoselect feature chooses working modes by using a double footswitch or twin button handles. This device is compatible with Argon-Z (Argon Plasma Coagulation).
ZERONE

Cutting power: 50 W - 300 W
Coagulating power: 100, 300 W
Frequency: 440 kHz
– special mono- and bipolar modes for arthroscopy, urology and gynaecology – Autostart/Autostop for mono- and bipolar modes – up to 100 personal user presets (programs) – flat front panel, easy to clean, with pushbuttons for modes ...

Cutting power: 1 W - 350 W
Coagulating power: 1 W - 150 W
... certain dangerous situation. D.Large vessel ligation E. It can start the argon system, the set of argon plasma coagulation system is completed by matching up with the argon ...

Cutting power: 400, 250 W
Coagulating power: 150, 120 W
... Endo Mode : Tissue feedback Pulse Interval controlled Pulse Cut for Polypectomy & Papillotomy. Argon Beam Coagulator up-gradable : ESU can be upgraded for Argon Beam Coagulation module. 6SENSE ...

... time and blood loss Argon plasma coagulation is regarded as one of the best therapeutic options in endoscopy and colonoscopy, and surgeries involving significant bleeding. Designed and manufactured with ...
WEM

Cutting power: 60 W - 400 W
Coagulating power: 70, 120, 100 W
Frequency: 425, 525 kHz
... immediately recallable procedures. EXTENTION DRIVER AND INTERLOCK SIGNALS Drived output connection to external Argon Plasma unit and Smoke Evacuator unit. AUTOMATIC ...

Argon (atomic number : 18 /Symbol : Ar) Plasma Jet treatment equipment that uses gas media and energy to release plasma. The output can be adjusted according to the treatment site ...

... Coagulation -Different coagulation modes provides precise, moderate, enhanced, contact-less coagulation effects -Possibility of argon plasma coagulation Bipolar -Coagulation with Forceps for contact ...

... Coagulation -Different coagulation modes provides precise, moderate, enhanced, contact-less coagulation effects -Possibility of argon plasma coagulation Bipolar -Coagulation with Forceps for contact ...

The plasma radiofrequency system allows rapid resection, ablation, coagulation and haemostasis of soft tissue at a relatively low temperature to ensure a clear surgical view during arthroscopic procedures.
Your suggestions for improvement: