• 18 samples/ hour • 5 positions • Tubes: Plus-Sed or Vacused • Results: in mm Westergren • Test time : 17 minutes
50 samples/hour 20 positions Tubes: Plus-Sed or Vacused Results: in mm Westergren Test time : 24 minutes
... positions Tubes: Plus-Sed or Vacused Results: in mm Westergren Test time: 24 minutes The useful tool for big needs on ESR Fast and capable for continuous work System Specifications Random Access • ...
ESR 3000, Performance comes in Handy Simply the handiest Random Access Analyzer for Easy Erythrocyte Sedimentation Rate Analysis Fast, simple and efficient Standard results Complete reliability ...
... Dimension: (l×w×h, mm) 560×360×300 Analyzer Introduction SD-1000 ESR analyzer uses voltage of 100-240VAC, which adapts to all level hospitals and medical research office, it’s used ...
Random Access and non-stop sample loading Correlated to Westergren Reference method At 30 minutes, 30, 60, 120 min. sedimentation results LOADING CAPACITY Max 100 samples - Max - 20 - samples ESRTUBE VOLUME 1,6 mL - 1,6 ...
... access •Up to 30 samples can be scanned simultaneously •Temperature compensation refers to 18°C according to Westergren method •ESR curve display and print-out •Touch screen, large LCD display •Built-in internal thermal ...
Available for one by one test at any position. Compact & Stylish Smart Rate 10: 2.6kg Smart Rate 20: 2.7kg Smart Rate 40: 3.0kg Rapid measurement Quick mode: 30 min value and 1hr value – 15 min working time 2 hr value ...
... :0mm/h-140mm/h Testing Accuracy:±1mm Repeatability : 0~10mm/h ESR: SD≤1.5mm/h More than 10 mm/h ESR: CV≤15% HCT CV ≤3% Performance characteristics Testing items ESR, ...
ChongQing NanFang Numericl Control Equipment CO.,LTD
Automatic instrument for the determination of the ESR directly on the hematocrit tube (190 samples/hour), using racks from the main cell counters. The first result is performed after 24 minutes. Host ...
Diesse Diagnostica Senese
... innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike ...
ALCOR Scientific
Simple operation. Only 3 steps: CB reading, homogenization (automatic), result report Intuitive and friendly: Android Operating System Modern: large touch screen. USB ports Free of maintenance Eco friendly: ...
unit of measurement - NR box quantity - 1 weight box kgs - 1.80 box dimensions mm - 300x265x275 boxes on a pallet - 1 pieces on a pallet - 1
LP ITALIANA SPA
Erythocyte Sedimentation Rate (E.S.R.) analyzer 20 test tubes positions, compact dimensions, fast and easy and intuitive to use. LCD Touch screen with backlight display and internal thermal printer. The ...
The SRA-48 is an automatic analyzer for measuring the speed of rate (modified Westergreen). Using vacuum tubes (also can be used without vacuum) of easy use to avoid any type of interference. The unit ...
... consumable system Real-time display of test progress, automatic printing of results Automatic identify the boundary between red cells and plasma, temperature correction available Loading disposable ...
Caretium Medical Instruments
... ESR curve display and print out Barcode reader optional Can connect LIS Specifications: Field of application - Erythrocyte sedimentation rate analysis Measuring principle - Infrared sensor Analysis ...
... possible ESR test capacity with an absolute minimum of handling. Maximum automation, yet still able to run an emergency sample. Development RR Mechatronics has a long and successful track record in automating Westergren ...
Mechatronics Instruments
ESR performed on the same Cell Blood Count (CBC) sample. No need of dedicated Citrate tubes. Innovative calculation algorithm supported by neural network. Continuous loading of samples. Results in only 25 minutes. 10 ...
KIMASED AUTO 20 ESR autoanalyzer 20 tubes positions. Testing time 24 minutes - 50 sample/hour. With built-in printer. The result is expressed in mm/hour as in the traditional Westergren system.
Vacutest Kima S.r.l.
Specification: Number of test samples: 10 items at the same time Max test speed: 20 samples/hour; Suited ESR tube: 1.6ml ESR tube(vacuum or normal); Sample volume: 1.6ml anticoagulant blood(blood 1.28ml ...
Automated Erythrocyte Sedimentation Rate Analyzer Features: ESR 2010 V4.0, is a Small; Compact; Desktop Random Access Analyzer 1 hour ESR results ...
ESR testing has important guiding significance for many clinical diseases, but the traditional standard Westergren method has complicated operation, low work efficiency and large cross-contamination. Automatic ...
1.Large 7 inch touch screen 2.Two working methods: 30mins or 60mins 3.ESR curve display and print out 4.Barcode reader optional, Support LIS connection Specifications Principle Field of application: - Erythrocyte sedimentation ...
... EDTA tubes Batch and STAT test mode Get results in 20 minutes with excellent Westergren correlation. Provide real ESR curve and Bio-Rad control assigned value. The state of art design with least maintenance US/Europe ...
Shenzhen Yhlo Biotech Co., Ltd.
... also be printed out in the forms of ESR results and ESR curves by the internal printer. Capable of storing 150 samples results and curves. Offers a simple safe economical and highly accurate method ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining