- Dental >
- Dental practice >
- Conical implant abutment
Conical implant abutments
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Implant diameter: 3 mm
Implant length: 12 mm
... overview
Temporary
abutment designed for provisional restorations on a
Conical Connection
implant platform 3.0. Engaging (rotationally locked) design for single-tooth provisionals; can be used ...
Nobel Biocare Services AG
... Gingiva Height 1.0 mm Connection Type NC Specifications Sterile No Prosthetic Solution Category Impression Level Impression Tray Open/Closed Tray Variobase® Indication Single Crown Fixation Screw-retained/Cement-retained Angulation ...
Implant diameter: 3.4 mm - 6 mm
Implant length: 3.8 mm - 6.8 mm
... workflow with the flexibility of adjusting the abutment at four different heights, and support with thicker abutment walls on wider implant platform diameters. Enabled Angles For Versatility access ...
Implant angulation: 35 °
... users and the integration of prosthetic products for conventional and digital restoration, immediate restoration with 4 to 6 implants is easy. The standardised protocols can be easily transferred to any practice and patients leave the ...
... secure positioning of implant prosthetic components during multiple laboratory procedures. The component is mounted onto the Fixing Pin, which is then firmly secured into the handpiece. Specifically developed for polishing abutments ...
... transverse forces on the restoration, in contrast to restorations screwed directly on the implant. We generally recommend the use of titanium bases for all screw-retained implant structures, particularly though for those ...
Implant length: 4.5, 3.5, 0.5, 2.5, 1.5 mm
... The Zirkonzahn Multi Unit Abutments, the Zirkonzahn Multi Unit Abutments 17° and the Zirkonzahn Multi Unit Abutments 30° are especially suitable for ...
Implant diameter: 3.4 mm - 5 mm
Implant angulation: 0, 15 °
... IML ensures the highest mechanical precision in the implant- abutment coupling and cancels micro-movements and allows a balanced masticatory loads on the whole implant systems reducing the bone stress ...
IML Swiss Dental Implants
Implant diameter: 3.4, 4, 4.5, 5 mm
Implant angulation: 15 °
... Usable with: Universe - Category: Provisional - Implant platform: ØU - Implant diameter: 3.4 mm, 4 mm, 4.5 mm, 5 mm - Shoulder height: 0 mm - Angle: Inclined 15° - Material: Peek - Abutment connection ...
IML Swiss Dental Implants
... precision in the implant- abutment coupling and cancels micro-movements and allows a balanced masticatory loads on the whole implant systems reducing the bone stress keeping it long-term healthy. USABLE ...
IML Swiss Dental Implants
... Duplex Milling Abutment Simplex Abutment Esthetic Abutment Transfer Imprssion Coping Solid Lab Analog Closing Screw Headless Screw Ball Cap Ball Lab Analog Solid Abutment Abutment ...
Implant diameter: 4.5 mm
... titanium abutment designed for single restorations.
Features
- Material:
ReplicaDent
Implant diameter: 4.5 mm
... mm
Kit contents
- Screw included
Clinical ...
ReplicaDent
Implant diameter: 4 mm
... Crown height: 10.0 mm
Premium ...
ReplicaDent
Implant diameter: 4 mm - 7 mm
... - Socket Type: Conical - Transgingival height (mm): 1–6, tolerance ±0.2 - Restorative height (mm): 4–10, tolerance ±0.2 - Abutment angle (°): 0–25°, tolerance ±1° - Abutment wall thickness ...
Implant diameter: 3.8 mm - 5.4 mm
Implant length: 5 mm - 7 mm
... Beauty-up Abutment (Angled SCRP) For Screw-Cement Retained Prosthesis with angulated screw channel. Solution for anterior aesthetic zone. The gingival line of the Beauty-up™ Abutment allows more aesthetic prosthesis. ...
Cowellmedi
Implant diameter: 3.87 mm
Implant length: 8.3 mm - 13.3 mm
... > For Over-denture Prosthesis > Various Sizes and Retention for Various Cases > Abutment Level Impression ...
Cowellmedi
Implant diameter: min 4.0 mm
Implant length: 5 mm - 10 mm
... > For Implant Supported Over-denture Prosthesis. > Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each colour) + 1 Block-out Spacer + 1 Outer Cap. > Direct impression. ...
Cowellmedi
Implant diameter: 3.8 mm
Implant length: 0.7, 1.5, 3 mm
... narrow S2.9 implants.BioniQ abutments present a wide range of options for individual solutions and customization according to specific needs and the patient's dentition. A narrower diameter of prosthetic components – ...
LASAK
Implant diameter: 4.9 mm
Implant length: 1 mm - 5 mm
Implant angulation: 17, 30 °
... non-parallel implants by correcting extreme angles of the implants. Straight and angled variants . 45, 52 and 60 degrees coming soon! Available in different collar heights. Easy and secure handling. CAD/CAM restoration. The ...
... For cement-retained, single- or multiple-unit prostheses; includes Abutment Screw; final torque: 30 Ncm; used with Ball-top Screw as a closed-tray, hexed-timed impression coping; gold-colored Titanium Nitride (TiN) coating for tissue ...
... prosthesis. ANGLED CONICAL ABUTMENTS Angled conical abutments are indicated for retrofitting of multiple prosthesis shafts. They come in indexed and non-indexed versions. It is recommended ...
Global D
Implant angulation: 15, 25 °
... usually spent milling standard abutments. Supplied with an individually packed SL8 laboratory fixing screw and S8 clinical screw. Dental Implant System ROOTT is a system of endosseous dental implants ...
TRATE AG
Implant diameter: 4.3 mm
... Connection: - Conical Connection Restoration type: - Screw retained Implant type: - V3, C1 Platform: - Narrow Platform Rotation: - Free rotation Diameter: - 4.3mm Gingival height: - 1mm Material: - Burnout plastic ...
MIS Implants Technologies Ltd.
Implant diameter: 3.3 mm - 4.8 mm
... the pre-mill abutments with a definitive abutment screw. The abutment screw is also made from a titanium alloy. You can continue to use your original instruments or instruments from Heliocos (Torx® driver). ...
Heliocos GmbH
Implant diameter: 3, 4.3, 3.5 mm
Implant angulation: 30, 20 °
... For large angular misalignments (20°/30°). The abutment's body consists of two parts, the so-called cup and the screwable tapered head section. The denture may be fixed to the abutment cone's screw thread ...
Bionika Medline Kft.
Implant angulation: 17, 30 °
... MULTI-UNIT ABUTMENTS FOR FIXATION OF OVERDENTURES. Upper conical connection ensures centring and passivity of the overdenture. Available with different gingival heights for optimal soft tissue adaptation. Pink ...
... S.I.N ® ( S.I.N Implant System ® Strong SW) Internal Hexagon ZM (Zimmer Biomet ® Tapered Screw - Vent®) 1- Implant Analogs 2- Digital Implant Analogs 3- Temporary Titanium Abutments 4- ...
Implant diameter: 3.3, 4.1, 5 mm
Implant length: 1.5, 2, 3 mm
Systhex Implantes
... Description • Abutment for removeable overdenture restoration or screwed prosthesis • Implant carried Bar-Restoration • l.S* Conical Connection for Bacterial Sealed Connection with Bone- and PapUla Retention • ...
Implant diameter: 3, 6, 4.2, 4.8 mm
... New implant connection: CONIC EVOAbutments compatible with Astra Tech Implant System™ EVDESS is proud to present the new CONIC EVO connection, which has been added to the current product range, including all corresponding ...
Implant diameter: 3.4, 4 mm
Implant angulation: 0, 20, 30 °
... and prosthetic switch from implant to gingival level. The impression post was designed as a universal abutment and can also be used, for example, to fix the prosthesis. A large number of prefabricated abutment ...
Medical Instinct Deutschland
Implant angulation: 15, 23 °
... Abutment, 15° angled, with shoulder - Transgingival height: 1,5 mm - 421501 screw P/N 0211 - Abutment, 15° angled, with shoulder - Transgingival height: 2,5 mm - 421502 screw P/N 0211 - Abutment, ...
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group