Analysis duration: 17 min
Sample volume: 0.1 ml
The PATHFAST™ system combines the accuracy of a full-scale lab analyzer with the flexibility of a mobile solution. Its compact design and low weight makes PATHFAST™ the ideal analysis system in laboratories, hospitals ...
Throughput: 30 p/h
Analysis duration: 11, 21 min
Number of tests: 5 unit
... insert the collection tube into the AQT90 FLEX analyzer Get your test results delivered directly through the HIS/LIS system to the medical records Make critical decisions fast: The AQT90 FLEX analyzer ...
Throughput: 200 p/h
Sample volume: 0.1, 0.005, 0.075 ml
Finecare™ FIA Meter X2 (also known as FS-2000) is a 16-channel fluorescence immunoassay analyzing system, with a high throughput of 200 Tests/hour, perfect for small-to-medium laboratory. Built-in waste cartridge box ...
Guangzhou Wondfo Biotech Co.,Ltd
Analysis duration: 14 min
Point-of-care analyzer exceeding laboratory quality standards A point-of-care automated system utilizing acridinium ester direct chemiluminescence technology, provides accurate quantitative results ...
Throughput: 144 p/h
Analysis duration: 13 min
MCL60 is a compact CLIA system. △Throughput: 144 t/h △Sample position: 20 △Reagent position: 8 △Sample types: whole blood, capillary blood, serum, plasma △Time to first result: 13min Advantages of MCL60 includes: · ...
Throughput: 150 p/h
Sample volume: 0.01 ml - 0.1 ml
The KHB Polaris V150 is a desktop fully automatic chemiluminescence immunoassay analyzer from the KHB Polaris series. It is designed for small and medium-sized laboratories, while also ...
Throughput: 360 p/h
Sample volume: 0.006 ml - 0.1 ml
ALP-AMPPD system sensitivity up to 102 mol/L, suitable for small molecule detection Patented non-contact 4-step magnetic separation system provides better mixing effect Relying on KHB reference laboratory, traceable to international ...
... determined and analyzed. detection principle and method To realize the detection of different items based on immunofluorescence analysis method. During the test, add the test sample to the loading well of the ...
The automatic chemiluminescence immunoassay analyzer A New Solution for Different Levels of Diagnostic Markets Throughput - 120T/H Time to first result - 14 min, 30 sec interval Amount ...
Magnetic particle acridinium ester chemiluminescence detection system Features The iMAGIN 1800 magnetic particle acridinium ester chemiluminescence detection system adopts the domestic mainstream ...
Fully automatic chemiluminescence immunoassay system Features Shine i1910 automatic chemiluminescence immunoassay system is a chemiluminescence ...
Throughput: 120 p/h
Automatic Chemiluminescence Analyzer(VIT700) Features Fast * 6 results in 12 minutes, One-click start. * Meet emergency requirements, 24-hour standby. Easy * Single reagent, test upon arrival. * ...
Throughput: 100 p/h
Fully Automatic Chemiluminescence Analyzer(VIT900) Features Fast * 15 minutes for the first result. * 24-hour standby and sample testing upon arrival. Flexible * Random, batch, emergency mode. * ...
... Cardiovascular cTnl, CK-MB, MYO, MPO, D-dimer, H-FABP, NT-proBNP, Hs-cTnl*, Hs-cTnT*, BNP*, S100-β* Inflammation PCT, Hs-CRP, CRP, SAA, IL-6* Diabetic nephropathy HbA1c, NGAL, MAU, Allergen IgE, ...
Throughput: 200 p/h
Analysis duration: 20 min
Sample volume: 0.005 ml - 0.15 ml
AutoLumo A2000 Plus is a fully automated chemiluminescence Immunoassay analyzer based on CLIA Microparticles platform, which is designed for both quantitative and qualitative ...
Sample volume: 0.07 ml - 0.15 ml
CLIA method POCT device with pg level sensitivity Easy Independent dual chamber design with 6-channels in each one Efficient All in one test cartridge ready to use, no standby reagent consumption Instrument ...
EasyDiagnosis
The WIZ-A202 continuous immunoassay analyser (hereafter referred to as the analyser), the analyser analyser uses a photoelectric conversion system and immunoassay ...
Shenzhen Afkmed
Throughput: 360 p/h
Analysis duration: 15 min
Sample volume: 0.015 ml
Sample and reagent barcode intelligent identification Liquid level detection, needle blocking alarm, air suction alarm Real-time monitoring and alarming of reagent remaining amount Intelligent monitoring, replenishment and alarm of ...
Throughput: 120 p/h
Automatic mode makes your time more efficient Automatic batch sample entering, suitable for Laboratory Department scene Test speed: 120T/H Puncture sample absorbing, support multi-specification test tube detection Product Description Characteristic ...
Test storage capacity: 1,000 unit
... Handheld Immunofluorescent Analyser Advantages: 1.Portable: only 0.3Kg 2.Quick: Read the test report within 3-15 minutes, less waiting time. 3.Easy: only 3- step operation 4.Accurate: CV<1%, comparable to large ...
Sichuan Xincheng Biological Co., LTD
Analysis duration: 2, 3, 5, 10, 15 min
Reports the quantitative results Closed system Reading: immunofluorescence Automatic calibration through chip Results in less than 15 minutes Simple user interface Supports up to 40 parameters ( customizable ) Automatically ...
Throughput: 120 p/h
... blood, plasma, serum, urine and peripheral blood. Number of Channels 12 Product Name KS-002 Dry Fluorescent Immunoassay Analyzer Testing Mode Automatic testing: the instrument automatically ...
Throughput: 120 p/h
Analysis duration: 90 s
Well-designed by Hipro, a professional medical instruments company, HP-AFS/1 PLUS is a fully automated immunoassay analyzer. New emergency priority mode. Build-in standard curve. Internal temperature ...
Analysis duration: 3, 5, 15, 10 min
Sample volume: 0.01 ml - 0.15 ml
Test storage capacity: 2,000 unit
High precision Optional printer Low cost of reagents Disposable consumable Specifications cv <5% Power supply Adapter input AC100~240V,50/60Hz,0.5A; output 5V,2A Built-in Lithium battery: DC 3.7V Measurement 95.6mm*96mm*183.5mm Weight ...
D-Dimer is critical for the diagnosis of deep vein thrombosis(DVT),pulmonary embolism(PE), and disseminated intravascular coagulation(DIC). The quantitative detection of D-Dimer ...
The Immunofluorescence Quantitative Analyzer developed basing on the advanced technologies(modern optics, electronics, computer science and immunochromatography, etc.) is a high-accurate and intelligent ...
Throughput: 120 p/h
Analysis duration: 15, 42 min
... critical tests 12 position reagent carousel Technical Specifications Overview System Description Random access immunoassay system Throughput Assays On Board Up to 12 Samples and Sample Handling Sample ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining