Diameter: 2.5, 4, 2.75, 3, 3.5 mm
Length: 12, 36 mm
... distal shaft provides outstanding pushability. Polymer-free design significantly reduces the inflammatory response after stent implantation to guarantee the long-term safety. Polymer-free design facilitates earlier endothelialization ...
Lepu Medical
Diameter: 3, 2.75, 3.5 mm
Length: 12, 15, 18, 21, 24 mm
... permanent retention of metal implants - Avoiding imprisonment in the “ metal cage” and recovering the vasomotor function - Performing positive remodeling and bringing late benefits to the lumen - Avoiding the risk of ...
Lepu Medical
Diameter: 2.25, 4.5 mm
Length: 8, 36 mm
... of inflammation caused by durable polymer • Better endothelialization Technical Parameters: Strut Thickness 75 μm Metal-artery Ratio 15% Recoil Ratio 3.40% Lowest Crossing Profile 0.035" (0.90mm) Balloon Tip Profile 0.017" Delivery ...
Lepu Medical
... Coroflex® ISAR NEO Sirolimus eluting polymer-free coronary stent system Coroflex® ISAR NEO is B. Braun´s next generation of Drug Eluting Stents. Thanks to the proven polymer-free matrix coating, it provides continuous ...
Diameter: 2.75, 3, 3.5, 4, 2.25, 2.5 mm
Length: 8, 12, 32, 38, 16, 20, 24, 28 mm
... Summary
The Promus ELITE™
Stent System is a platinum‑chromium (PtCr) coronary
stent system combining a customized
stent architecture with Everolimus drug elution and a permanent PVDF‑HFP polymer ...
Boston Scientific
... Non-irritating ends for patient comfort Precise compression for target areas Maintains length integrity Repositioning capability as needed Flare ends and partial covering reduce migration risk Silicone coating provides protection Versatile ...
STERIS
... vessel support to demonstrate superior 5-year results against percutaneous transluminal angioplasty (PTA) and Zilver bare- metal stents. ...
Diameter: 2.5, 3, 3.5, 4, 2.25 mm
Length: 13, 18, 26, 35, 40 mm
... for discrete de novo stenotic lesions and in- stent restenotic lesions. Product Highlights Outstanding patient outcomes Highly deliverable Ultrathin 60ᵇ μm struts Technical Data - Stent material - ...
Biotronik
Diameter: 40, 18, 25, 26, 35 mm
Length: 12, 18, 20, 14, 16 mm
... Biodegradable Drug Eluting Sinus Stents are used after Functional Endoscopic Sinus Surgery (FESS) or without surgery for anti-inflammatory and anti-adhesion purposes. Product Features More shapes, higher compatibility in cavity Fully ...
Diameter: 10 mm
Length: 40, 100, 80, 60 mm
... Our range of Biliary stents includes covered and non-covered versions Features Optimal radial force with lineal flexibility Covered & Non Covered versions available Optimal Returning Force Non-irritating ends Reduced shortening Re-positionable ...
... device is BARD ® ELUMINEXX ® Biliary Stent. • The Stent (Implant) is equipped with four highly visible radiopaque PUZZLE ® Tantalum Markers on both the proximal and distal end. • The BARD ® ELUMINEXX ® Biliary Stent ...
Diameter: 2.25, 3, 3.5, 4, 2.75 mm
Length: 8, 16, 28, 38, 43 mm
... The EUROLIMUS™ Sirolimus eluting coronary stent system is made of a coated cobalt-chromium alloy (L605) stent and a rapid-exchange catheter. Eurolimus is indicated for use in patients with symptomatic ischemic coronary ...
Diameter: 2, 2.75, 3, 3.5, 4 mm
Length: 8, 16, 24, 32, 40 mm
... The E-Magic™ Plus Sirolimus eluting coronary stent system is a coronary stent system, made of a coated cobalt-chromium alloy (L605) stent and a rapid-exchange catheter. The E-Magic Plus is indicated for ...
Diameter: 2.25, 2.5, 2.75, 3, 4 mm
Length: 8, 18, 23, 31, 38 mm
... Rapamycin Target Eluting Coronary Stent System It is the world’s innovative Rapamycin target eluting coronary stent system with real world outcomes, higher safety and efficacy and less drug dosage and more drug release ...
Diameter: 28, 30 mm
Length: 30 mm
... • Covered to prevent leakage & tissue in-growth. • Wide & acute flares, to prevent migration. • Large stent diameter, to perform safe & easy retrieval of pancreatic necrosis. ...
MITRA Industries
Diameter: 26 mm
Length: 30 mm
... flares for lumen apposing between pancreas and gastric wall. • Fully covered to prevent leakage. • Optimal radial force of stent body. • 9 radiopaque markers for better fluoroscopy guidance. ...
MITRA Industries
Diameter: 16 mm
Length: 60 mm
... • Finned design to prevent outward migration. • Fully & partially covered design. • Wide proximal flare end to prevent inward migration. • Re-capturing properties up to 80%** during deployment. ...
MITRA Industries
Length: 26, 28 cm
... Ureteral stents Model 4F/4.7F/5F/6F/7F/8F Length 26cm/28cm End Double J, single open/double open ends Option accessories Stainless steel guidewire, pusher, conectors Customization is available. Indication Used ...
Diameter: 2.5, 2.75, 3, 3.5, 4 mm
Length: 10, 16, 22, 28, 38 mm
... coated stent animal experiment report Scanning of electron microscopy Two weeks after stent implantation, most of the titanium-oxide coated stent was basically covered by endothelium, while a large ...
Diameter: 2, 5 mm
Length: 7, 38 mm
... and Very Late Stent thrombosis thus making compulsory prolonged DAPT. BIO ACTIVE STENT BIOMECHANICS Thinner Stent System «Balloon-like» navigability Expanded crossing capabilities Advanced Cobalt-Chromium ...
... Amphilimus (sirolimus + Fatty acid) eluting coronary stent Product key features: - Polymer-free Abluminal Reservoir Technology - Amphilimus™ formulation: Sirolimus + Fatty Acid - New stent architecture - ...
Alvimedica
... COMBO is the world’s first and only dual therapy stent designed to repair vessel injury and regenerate the endothelium, fostering natural, true vessel healing. It does this by accelerating endothelial coverage and controlling neo-intimal ...
OrbusNeich
... Introducing the Novolimus-eluting DESyne stent - the next generation drug eluting stent with improved performance and superior clinical efficacy and safety1. Engineered on a clinically- proven cobalt chromium platform, ...
Elixir Medical
... carrier-free Drug Coated Stent with BA9™ (DCS). BioFreedom™ Ultra is a novel CoCr stent (84µm struts for specific stent diameter (small vessel)), that will optimize the PCI procedure. for HBR patients ...
Biosensors International
... address the unique challenges of acute type A aortic dissection, specifically DeBakey Type I (ATAD I). DANE Prevention – The stent-supported cuff of the AMDS and expansion of the device from the arch distally elevates and support the ...
... balloon at the distal end of the catheter.The stent is manufactured from a metal tube that is laser cut and subsequently subjected to various treatments that will give the surface a smooth, glossy finish. The stent ...
iVascular
... the construction of the stent Excellent pushing ability and tracking features Coflexus uses L605 Co-Cr. The application of this exceptional material enables us to reduce the thickness of the stent’s wall and also ...
Balton
Diameter: 2.25, 2.75, 3, 3.5, 4 mm
Length: 8, 12, 18, 24, 30 mm
... indicates good stent-to-wall apposition. Hybrid cell design – MSW technology Closed cell ends for good anchoring and open cell mid-section for low metal-to-artery ratioClosed cell ends for good anchoring and open ...
Rontis Medical
... CROWNUS™ Peripheral Stent System is intended for the treatment of stenosis or occlusive in iliac, femoral and subclavian artery. The stent is made of self-expanding TiNi shape memory alloy. The catheter is rapid exchange ...
... The Direct- Stent Cobalt Chromium has emerged as a champion with its durable, flexible stent design with the proven Direct- Stent platform. The device features. The Cobalt Chromium supports the interventionists ...
InSitu Technologies
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group