- Secondary care >
- Cardiology >
- Metal stent
Metal stents
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... Coroflex® ISAR NEO Sirolimus eluting polymer-free coronary stent system Coroflex® ISAR NEO is B. Braun´s next generation of Drug Eluting Stents. Thanks to the proven polymer-free matrix coating, it provides continuous ...
Diameter: 2.5, 4, 2.75, 3, 3.5 mm
Length: 12, 36 mm
... distal shaft provides outstanding pushability. Polymer-free design significantly reduces the inflammatory response after stent implantation to guarantee the long-term safety. Polymer-free design facilitates earlier endothelialization ...
Lepu Medical
Diameter: 3, 2.75, 3.5 mm
Length: 12, 15, 18, 21, 24 mm
... permanent retention of metal implants - Avoiding imprisonment in the “ metal cage” and recovering the vasomotor function - Performing positive remodeling and bringing late benefits to the lumen - Avoiding the risk of ...
Lepu Medical
Diameter: 2.25, 4.5 mm
Length: 8, 36 mm
... of inflammation caused by durable polymer • Better endothelialization Technical Parameters: Strut Thickness 75 μm Metal-artery Ratio 15% Recoil Ratio 3.40% Lowest Crossing Profile 0.035" (0.90mm) Balloon Tip Profile 0.017" Delivery ...
Lepu Medical
Diameter: 2.75, 3, 3.5, 4, 2.25, 2.5 mm
Length: 8, 12, 32, 38, 16, 20, 24, 28 mm
... Summary
The Promus ELITE™
Stent System is a platinum‑chromium (PtCr) coronary
stent system combining a customized
stent architecture with Everolimus drug elution and a permanent PVDF‑HFP polymer ...
Boston Scientific
... Non-irritating ends for patient comfort Precise compression for target areas Maintains length integrity Repositioning capability as needed Flare ends and partial covering reduce migration risk Silicone coating provides protection Versatile ...
STERIS
... to support every phase of the product life cycle for manufacturing neurovascular stent components. Manufacture of stent components and assemblies for neurovascular stents. Advanced manufacturing ...
Greatbatch Medical
... Non-irritating ends for patient comfort Precise compression for target areas Maintains length integrity Repositioning capability as needed Flare ends and partial covering reduce migration risk Silicone coating provides protection Versatile options, ...
STERIS - CANTEL
Diameter: 40, 18, 25, 26, 35 mm
Length: 12, 18, 20, 14, 16 mm
... Biodegradable Drug Eluting Sinus Stents are used after Functional Endoscopic Sinus Surgery (FESS) or without surgery for anti-inflammatory and anti-adhesion purposes. Product Features More shapes, higher compatibility in cavity Fully ...
... vessel support to demonstrate superior 5-year results against percutaneous transluminal angioplasty (PTA) and Zilver bare- metal stents. ...
Diameter: 2.5, 3, 3.5, 4, 2.25 mm
Length: 13, 18, 26, 35, 40 mm
... for discrete de novo stenotic lesions and in- stent restenotic lesions. Product Highlights Outstanding patient outcomes Highly deliverable Ultrathin 60ᵇ μm struts Technical Data - Stent material - ...
Biotronik
... device is BARD ® ELUMINEXX ® Biliary Stent. • The Stent (Implant) is equipped with four highly visible radiopaque PUZZLE ® Tantalum Markers on both the proximal and distal end. • The BARD ® ELUMINEXX ® Biliary Stent ...
... navigating tortuous biliary anatomy
Diameter: 2.25, 2.5, 2.75, 3, 4 mm
Length: 8, 18, 23, 31, 38 mm
... Rapamycin Target Eluting Coronary Stent System It is the world’s innovative Rapamycin target eluting coronary stent system with real world outcomes, higher safety and efficacy and less drug dosage and more drug release ...
Diameter: 28, 30 mm
Length: 30 mm
... • Covered to prevent leakage & tissue in-growth. • Wide & acute flares, to prevent migration. • Large stent diameter, to perform safe & easy retrieval of pancreatic necrosis. ...
MITRA Industries
Diameter: 26 mm
Length: 30 mm
... flares for lumen apposing between pancreas and gastric wall. • Fully covered to prevent leakage. • Optimal radial force of stent body. • 9 radiopaque markers for better fluoroscopy guidance. ...
MITRA Industries
Diameter: 16 mm
Length: 60 mm
... • Finned design to prevent outward migration. • Fully & partially covered design. • Wide proximal flare end to prevent inward migration. • Re-capturing properties up to 80%** during deployment. ...
MITRA Industries
Length: 30, 100, 150, 200, 250 mm
... Overview
The
metal ureteral
stent system from Surgsci Medical Ltd. is designed to provide long-term ureteral drainage and mechanical support in patients with ureteral obstruction. It combines a
metal ...
... Medical Ltd.
Specifications / Technical characteristics
- Device type: Metal ureteral stent
Diameter: 2, 2.3, 1.3, 1.6 mm
Length: 260, 450 mm
... Description
5 | 45 | Single-J
stent, Pusher 1.6 mm, clamp
6 | 45 | Single-J
stent, Pusher 2.0 mm, clamp
7 | 45 | Single-J
stent, Pusher 2.0 mm, clamp
8 | 45 | Single-J
stent, ...
Hunan Endovascular Device Co., Ltd.
Diameter: 1.6, 2 mm
Length: 26 cm
... Class III Ureteral Stent is a Class III medical device intended for drainage and temporary indwelling of the upper urinary tract (up to 90 days). Manufactured from imported thermosensitive material with an optimized structure, the stent ...
Hunan Endovascular Device Co., Ltd.
Diameter: 10, 9 mm
Length: 155, 100, 120, 195 mm
... /li>
Ureteral Stent System (dimensions)
Ureteral Stent System
OD (mm) | Length (mm)
9.0 | 195
10.0 | 100
10.0 ...
Hunan Endovascular Device Co., Ltd.
Length: 26, 28 cm
... Ureteral stents Model 4F/4.7F/5F/6F/7F/8F Length 26cm/28cm End Double J, single open/double open ends Option accessories Stainless steel guidewire, pusher, conectors Customization is available. Indication Used ...
Diameter: 2.5, 2.75, 3, 3.5, 4 mm
Length: 10, 16, 22, 28, 38 mm
... coated stent animal experiment report Scanning of electron microscopy Two weeks after stent implantation, most of the titanium-oxide coated stent was basically covered by endothelium, while a large ...
Diameter: 2, 5 mm
Length: 7, 38 mm
... and Very Late Stent thrombosis thus making compulsory prolonged DAPT. BIO ACTIVE STENT BIOMECHANICS Thinner Stent System «Balloon-like» navigability Expanded crossing capabilities Advanced Cobalt-Chromium ...
... Amphilimus (sirolimus + Fatty acid) eluting coronary stent Product key features: - Polymer-free Abluminal Reservoir Technology - Amphilimus™ formulation: Sirolimus + Fatty Acid - New stent architecture - ...
Alvimedica
... COMBO is the world’s first and only dual therapy stent designed to repair vessel injury and regenerate the endothelium, fostering natural, true vessel healing. It does this by accelerating endothelial coverage and controlling neo-intimal ...
OrbusNeich
... Introducing the Novolimus-eluting DESyne stent - the next generation drug eluting stent with improved performance and superior clinical efficacy and safety1. Engineered on a clinically- proven cobalt chromium platform, ...
Elixir Medical
... carrier-free Drug Coated Stent with BA9™ (DCS). BioFreedom™ Ultra is a novel CoCr stent (84µm struts for specific stent diameter (small vessel)), that will optimize the PCI procedure. for HBR patients ...
Biosensors International
... address the unique challenges of acute type A aortic dissection, specifically DeBakey Type I (ATAD I). DANE Prevention – The stent-supported cuff of the AMDS and expansion of the device from the arch distally elevates and support the ...
... balloon at the distal end of the catheter.The stent is manufactured from a metal tube that is laser cut and subsequently subjected to various treatments that will give the surface a smooth, glossy finish. The stent ...
iVascular
... the construction of the stent Excellent pushing ability and tracking features Coflexus uses L605 Co-Cr. The application of this exceptional material enables us to reduce the thickness of the stent’s wall and also ...
Balton
Diameter: 2.25, 2.75, 3, 3.5, 4 mm
Length: 8, 12, 18, 24, 30 mm
... indicates good stent-to-wall apposition. Hybrid cell design – MSW technology Closed cell ends for good anchoring and open cell mid-section for low metal-to-artery ratioClosed cell ends for good anchoring and open ...
Rontis Medical
... CROWNUS™ Peripheral Stent System is intended for the treatment of stenosis or occlusive in iliac, femoral and subclavian artery. The stent is made of self-expanding TiNi shape memory alloy. The catheter is rapid exchange ...
... The Direct- Stent Cobalt Chromium has emerged as a champion with its durable, flexible stent design with the proven Direct- Stent platform. The device features. The Cobalt Chromium supports the interventionists ...
InSitu Technologies
Diameter: 3, 4, 2.5, 3.5 mm
Length: 9, 29, 24, 18, 34 mm
... Available with coating technology for increased patient safety Compatible with 0.021" microcatheter* Independently movable wire for enhanced safety Platinum filled DFT wires provide full visibility Friction-locking principle ...
Phenox
... the tumor tissue ingrowth ,reducing the possibility of second stenosis. 4. Lasso in the near-end of the stent , easy to be recycled. 5. The stent is clear visibleunder image equipment. Positioning is more accurate. ...
Changzhou Health Microport Medical Devices
Diameter: 6, 5, 3, 8, 7 mm
Length: 40, 170, 120, 60, 20 mm
... excellent steerability¹ over a 0.018 inch guide wire Broad range of stent sizes Stent diameters from 3 – 8 mm Stent lengths from 20 – 170 mm New stent design Peak-to-valley ...
OptiMed
Diameter: 2.25, 2, 3, 4, 3.5 mm
Length: 8, 40, 32, 23, 15 mm
Length: 20, 150 mm
... The 36 strut, 6 bridge construction of the S.M.A.R.T. CONTROL Stent provides an optimal wall apposition. The S.M.A.R.T. CONTROL Stent design offers crush recoverable endovascular stent with optimal ...
Cordis
Diameter: 6, 8, 10 mm
Length: 100, 90, 80, 40, 50 mm
... ' discomfort. 2.Imaging markers of the stents are clear visible under image equipment .Positioning is more accurate. 3.Re-positioned introducer system (When releasing less than two-thirds of the length, Stents can be ...
Hunan Fude Technology
... thinnest Chromium Cobalt Coronary Stent (65µ) available on the market with an innovative Finishing Surface Treatment (FST). Coral® is NATEC Medical coronary stent proposed on an OBL or OEM basis. Coral® is a closed-cell ...
Diameter: 22, 30, 24, 28 mm
Length: 60, 170 mm
... HANAROSTENT Double Layer Stent features a unique construction, with each wire mesh, but keeping same volume. The inner layer helps to increase the radial force that opening the enteral lumen. The double layer of the outer ...
M.I Tech
... Balloon Expandable Coronary Small Vessel Stent 090 mm strut thickness 30 - 0.35 bar radial strength 090 mm strut width 070 mm articulation width ...
Vascular Concepts
... Coronary Stent System Translumina - The surface matters • Stent surface with unique micro-pores • Homogeneous stent expansion • Increased radial force • Good side branch access • Flexible and deliverable ...
Translumina
Diameter: 2.5, 4, 3.5, 3, 2.75 mm
Length: 23, 18, 12, 8, 28 mm
... Drug-loaded coronary stent system without polymer micro-blind holes Product Description Yinyi® polymer-free microblind drug-loaded (paclitaxel) coronary stent (hereinafter referred to as "Yinyi® stent") is ...
Liaoning Yinyi Biological Technology
Diameter: 2.25, 2.75, 3.25, 4, 5 mm
Length: 8, 13, 23, 33, 48 mm
... Ultrathin 65 µm Design Excellent Deliverability Degradable Polymermatrix Synchronized Polymerdegradation and Drug Release Wide Range of Sizes 36 Months Shelf Life ...
eucatech
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.