... Specifications Instrument type: - Stand alone bench top Processing Capability: - 4 to 96 samples per run Processing Time: - Typically under 3 hours for 96 samples Temperature Control: - PID under software ...
... Q-Processor is an immunoassay sample processing device including washing, incubating, and processing for biological samples on allergy panels Specification Integrated PC 10 tests in one process ...
... automatic timers for test reactions to ensure the reliability of test results. Product Features ACCURACY: • Incubation system control temperature variation ≤± 0.1℃ EASE-OF-USE: • Simple temperature adjustment • Easy incubation ...
... A simple, easy to use small autostainer system for rapid immunohistochemistry (IHC) testing. This flexible system can perform frozen tissue, H&E, and FFPE tissue testing. This system, along with its ...
... accuracy of results • Safe and intelligent sample pre-processing • Reagent shortage automatic alarm function, test completed automatic reminder function • Fully automatic sample preparation, ...
... Automates Chromosome and MicroFISH Slide Preparation A liquid handling robot that automates preparation of chromosome and MicroFISH slides. For G-banding applications, it dispenses fixed cells in a humidity-controlled ...
SciGene
... Process Standard process modules, and effective coverage of different process requirements. Technology Platform Open system, excellent process adaptability. Integration Integrated automation line,fully automatic operation. Distributed ...
... adhesive features Easy operation with front panel Carousel button for rapid loading Automatic cleaning system No cross contamination Secure slide fixation within the staining chamber Easy Setting of Staining Method ...
Labtron Equipment
... can be carried out immediately and various IHC stain experiments can be arranged randomly. Full Automatic System: A full flow automatic system of IHC includes the experiment protocol of slice drying, deparaffination, ...
Celnovte Biotechnology Co., Ltd.
... It provides a single platform for all GC sample preparation. Cryogen-free analyte trapping provides high sensitivity by delivering a sharp, concentrated band of vapour to the GC. It is the only system ...
SepSolve
... Automated NGS Library Preparation System (ELPS-01) developed by MyGenostics Inc. is used for library preparation and target capture before high-throughput sequencing (NGS). The system ...
MyGenostics Inc.
... instrument for the Immuno Fluorecence Assay on Glass. UNIQO is the new high-performance automated system for the IFA procedure, from slide preparation to test reading and validation. It provides laboratories with ...
VISIA Lab S.r.l.
Throughput: 32 p/h
... Microfluidic technology is the process of analyzing samples in biology, chemistry, medicine and other fields, including preparation, reaction, separation, detection and other basic units integrated into a micron-scale ...
Throughput: 8, 16, 32 p/h
... The copy number (concentration) of the sample can be calculated using the number of fluorescent droplets through Poisson distribution. The DropX-2000 System utilizes advanced microfluidics technology to achieve sample ...
... selectable options. SMU - Horizontal type Reagents applied method - Injection Reagent amount per cycle - Targeted samples only Heating method - Circulating heated air Dimensions - 51 x 55 x 27 cm Weight - 23 kg (51 lbs) Warranty ...
Medschenker
... staining procedures. Easy to use. ♦ Equipped with touch-screen display. ♦ Environmental friendly. Special hydraulic control system can prevent liquid evaporation, reduce reagent consumption and air pollution. ♦ Compact size, about ...
... FT-PRO Auto System is an automatic flow-through hybridization device. This platform adopts the patented flow-through hybridization technology in addition to its automatic operation. Its sophisticated design drastically improves the quality ...
... Product features 1,Industrialized control system makes stable operation for 24 hours 2,High product yield and good purity 3,Automatic nucleic acid extraction processing can be performed on 32/96 samples simultaneously, ...
Throughput: 1 p/h - 32 p/h
... Automate low-throughput sample preparation within your laboratory workflow using Magnetic Particle Processors INOPurAuto-20 Automated Nucleic Acid Purification System. It for processing volumes ...
... VERI-Q PREP M16 System is a device, which is included membrane, to extract nucleic acid using tube. Features Fast Flexible Operation Compact Low Cost High Performance Compact 13 kg weights Low Cost To maximizing cost ...
completed, an innovative robot arm transfers the slide racks from the stainer to the washing rack then to the dryer rack and the slide ready for testing. no user intervention is required. Incubation time and agitation flexible rinsing and heated or non-heated ...
... Morphology (Cell form is keeping well). Reproducibility Smear is evenly distributed. Representative Cell quantities are great at least 5,000 cell. Clean Background Remove unused cell (Blood, mucus, inflammation cell etc.) Simple ...
... The FLEXTRAC is a unique intelligent monorail conveying system for hospital use, invented and developed by ENERGIUM. It takes test tubes from the place where blood is collected to the diagnostic laboratory. The FLEXTRAC ...
... It can process heated sample slides quickly, dewaxing and perform enzymatic digestion to release nucleic acids for qualitative or quantitative detection of nucleic acids in the tissue. Fully Automatic FISH Pretreatment System ...