Stents

Do you need help making a decision?  Take a look at our buying guide
109 companies | 399 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
Search
Stents | Choosing the right stent
Stents are mainly made from the following five types of materials: metallic, coated, drug eluting, bioresorbable and radioactive. Metallic: Some stents are made of bare metal (i.e. only metal). We can distinguish between: Stainless steel: this is the most common material used for stents. Its advantages include good X-ray visibility; a fairly elastic and resistant consistency; and good biocompatibility. These qualities make this type of stent very suitable...
coronary stent
coronary stent
eucaLimus

Diameter: 2.25, 2.75, 3.25, 4, 5 mm
Length: 8, 13, 23, 33, 48 mm

... Ultrathin 65 µm Design Excellent Deliverability Degradable Polymermatrix Synchronized Polymerdegradation and Drug Release Wide Range of Sizes 36 Months Shelf Life ...

See the other products
eucatech
femoral artery stent
femoral artery stent
Tentos 4F

Diameter: 6, 5, 3, 8, 7 mm
Length: 40, 170, 120, 60, 20 mm

... range of stent sizes Stent diameters from 3 – 8 mm Stent lengths from 20 – 170 mm ‍ New stent design Peak-to-valley open-cell stent strut design with high flexibility Excellent ...

See the other products
OptiMed
coronary stent
coronary stent
DECENT S

Diameter: 2, 2.5, 3, 3.5, 4 mm
Length: 10, 18, 24, 34, 38 mm

... Sirolimus-Eluting Coronary Stent System Double-Protection Technology For Outstanding Results This is how the Accura Decent S achieves outstanding results: Carbon-Ion surface treatment technique results in extraordinary stent ...

See the other products
Accura Medizintechnik
coronary stent
coronary stent
CR2 series

Diameter: 5, 2 mm
Length: 8, 40 mm

... luminal diameter and reduce restenosis within the stent and at the stent edges in native coronary arteries,de novo chronic total coronary occlusions and improving coronary artery luminal diameter in patients. Stent ...

See the other products
Invamed
ureteral stent
ureteral stent
B38 Series

... ureteral stents offer maximum compression resistance combined with ease of placement, enhanced flow and exceptional patient tolerance. The stent's wire-reinforced wall maximizes the inner lumen, allowing a degree of ...

renal artery stent
renal artery stent
X-Filter™

Length: 150 cm

... Anti-migration Device PASS Safe & effortless navigation past occlusion FRAGMENT Improved stone fragmentation TRAP Effective retention and immobilization of stone fragments CLEAR Swift removal of stone debris through irrigation STEP ...

See the other products
ROCAMED
coronary stent
coronary stent
Track

... The TRACK Coronary Stent family made of cobalt chromium and optimized for specific area of use. These stent systems provide high end performance with less metal and reliable outcomes. The Track Family offers two lesion ...

prostatic stent
prostatic stent
Memokath™028

... non-allergenic metallic stent used to effectively treat prostatic obstruction without the side-effects of major surgery, or discomfort of catheters. Brief introduction Memokath™ 028 Prostate is a non-allergenic metallic stent ...

See the other products
PNN Medical
peripheral stent
peripheral stent
mc-peripheral 6F

... Self-expandable Nitinol Stent Our mc-p peripheral 6F stents are available from 30 mm to 200 mm and with radial forces and designs that are individually tailored to your specific requirements. Braided outer sheath ...

See the other products
Medicut Stent Technology
coronary stent
coronary stent
Fantom®

The Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold combines the trusted anti-proliferative drug, Sirolimus, with Tyrocore™, REVA’s new proprietary polymer, to make the world’s first radiopaque bioresorbable scaffold for percutaneous coronary ...

coronary stent
coronary stent
EluNIR

Diameter: 3, 3.5, 2.5, 2.75, 2.25 mm
Length: 15, 8, 12, 17, 20 mm

... Implantation Dr. Alaide Chieffo, MD; Dr. Francesco Giannini, MD The first implantation of the EluNIR elastomeric drug-eluting stent. A complex case involving a flow-limiting lesion in a native coronary artery post an extremely tortuous ...

See the other products
Medinol
coronary stent
coronary stent
XINSORB™

Diameter: 3.5, 2.75, 3 mm
Length: 15, 18, 23, 12 mm

... coronary rapamycin eluting stent system" (xinsorb stent), which is the first in China and has the world leading level. It is the fourth innovation of coronary intervention after balloon dilation, bare metal stent ...

ureteral stent
ureteral stent
HEPARIUS®

... graduated This »HEPARIUS®« long-term stent can be used with a guidewire of your choice: For stents Ch. 4,8: guidewire 0,028" For stents Ch. 6+7: guidewire 0,035" Right after positioning of the ...

See the other products
UROMED
esophageal stent
esophageal stent
BD

Diameter: 18, 20, 23, 25 mm
Length: 60, 80, 100, 135 mm

... degradation process. At higher pH, stent degradation is slower, at lower pH, stent degradation is faster. Low migration is achieved by uncovered stent design. Polydioxanone is not visible under X-ray, ...

See the other products
ELLA-CS
esophageal stent
esophageal stent
S-ES series

Diameter: 18 mm
Length: 50, 100, 120, 150 mm

... Available with an introducer system Used to treat tracheoesophageal fistulas and expansion treatment of esophageal stenosis caused by esophageal carcinoma, chemical injuries, cardiac carcinoma, anastomotic stenosis, and other trauma which are surgically ...

See the other products
Shaili Endoscopy
bronchial stent
bronchial stent
NOVATECH® GSS™

... tolerance of the stents is to use a stent which is perfectly adapted to the patient’s needs. For this reason and in order to be prepared for any situation, it is essential to provide the physician with a basic line of ...

pancreatic stent
pancreatic stent

... The design of the double pigtail prosthesis prevents distal or proximal migration of the stent and offers the advantage of secure fixing. The tapered stent tip facilitates the passage through narrow structures. Also suitable ...

See the other products
Dispomedica
ureteral stent
ureteral stent
MONOSTAR SOFT

Length: 70 cm

... Mono-J Ureteral Stent Set Soft material Ureteral Especially soft material to ensure a high level of patient comfort Drainage openings only available for pigtail Open tip Markings for exact positioning Radiopaque Adapter For ...

See the other products
Urovision
ureteral stent
ureteral stent

... Temperature-controlled disposable ureteral stent, it becomes soft into the body for 3-5 minutes to reduce mucosal stimulation; Resilient, smooth, it can be kept in the body for months; Medical high polymer materials with superb ...

coronary stent
coronary stent
DES

... lesion treatment. - The drugs and polymers coated on the stent are all degradable and thus only the metal compositions will remain. Improved flexibility - The open cell structure allows the stent to move flexibly and ...

See the other products
Genoss
coronary stent
coronary stent
MOMO®

... it restores the original level of blood flow by physically widening the vessel. MOMO® is a bare metal stent—that is, a type of coronary artery stent that does not use drugs. Its surface is coated with a nano-level coating ...

ureteral stent
ureteral stent

... For temporary internal drainage from the renal pelvis to the bladder Stent features: Amecath double loop stent is made of polyurethane: Tecoflex for short term period Carbothane for long ...

ureteral stent
ureteral stent
45.04.020 series

Length: 15, 22, 24, 26, 28 cm

... · Designed to facilitate easy placement and prevent stent migration. · Markers that visualize stent advancement and placement. · Low encrustatian tendency. · Soft bady designed to enhance patient comfort. FEATURES Hydrophilic ...

coronary stent
coronary stent
Amaranth FORTITUDE™

... Minimal recoil Prolonged mechanical integrity and stability The FORTITUDE™ scaffold affords the strength of metal stents to assist the artery during the remodeling process following an interventional procedure, yet FORTITUDE™ ...

peripheral stent
peripheral stent
BioMimics 3D™

... Vascular Stent System Veryan has developed innovative technology to improve the performance of vascular stents by adopting the principle of biomimicry; developing structures that imitate those occurring naturally. The ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us
MedicalExpo RFQ: Free quotation comparison tool
Receive and compare quotations for free
Describe your project
We select
the best suppliers