Class II microbiological safety cabinet Sterilsafe
laboratoryfloor-standingEN 12469

class II microbiological safety cabinet
class II microbiological safety cabinet
Add to favorites
Compare this product
 

Characteristics

Class
class II
Applications
laboratory
Configuration
floor-standing
Certifications
EN 12469
Other characteristics
laminar flow
Window opening

Max.: 490 mm
(19.29 in)

Min.: 200 mm
(7.87 in)

Sound level

41 dB, 42.5 dB, 47 dB, 49 dB

External width

1,045 mm, 1,350 mm, 1,655 mm, 1,960 mm
(41.14 in, 53.15 in, 65.16 in, 77.17 in)

External depth

855 mm
(33.66 in)

External height

1,545 mm
(60.83 in)

Internal width

887 mm, 1,192 mm, 1,497 mm, 1,802 mm
(34.92 in, 46.93 in, 58.94 in, 70.94 in)

Internal depth

580 mm
(22.83 in)

Internal height

740 mm
(29.13 in)

Weight

170 kg, 195 kg, 225 kg, 260 kg
(374.79 lb, 429.9 lb, 496.04 lb, 573.2 lb)

Description

The series of Class II microbiological safety extractor hoods are designed and manufactured according to the performance requirements of EN12469: 2000 and are used in all situations where it is necessary to protect the operator and the environment from the harmful effects of uncontrolled spreading of airborne contaminants and, equally, to ensure that no environmental interference of a microbiological nature can affect the product during its handling. These hood families have normally been used in Microbiology, Virology, Haematology and Cell Culture laboratories. They are increasingly being used in innovative fields of research and in particular for the manipulation of: recombinant DNA Oncogenic viruses Pathogens These hood lines are defined: BIOHAZARD Class II they are equipped with a partial frontal working opening allowing the suction of 30% of the total air involved at a minimum speed of 0.4 m/s and a recirculation system for the remaining 70% which is sent to the working area in laminar flow at an average speed of 0.4 m/s (as defined by EN 12469 standards). Type A1, according to NSF 49 (U.S.A.) standards, can be used safely even if the expelled air coming from the frontal barrier is returned to the environment. Type A2 as, according to NSF 49 (U.S.A.) regulations, the expelled air can be channeled towards the outside of the room where it is used (for further technical details see the dedicated paragraph). Countertop model Models 48 and 72 certified according to standard EN12469: 2000 Glass with a motorized up-and-down mechanism One power socket for models 36 and 48, 2 for models 60 and 72 Vacuum circuit with tap