Class III biological safety cabinet BSC series
containmentfloor-standingwith HEPA filter

Class III biological safety cabinet - BSC series - Antech Group - containment / floor-standing / with HEPA filter
Class III biological safety cabinet - BSC series - Antech Group - containment / floor-standing / with HEPA filter
Add to favorites
Compare this product
 

Characteristics

Class
class III
Applications
containment
Configuration
floor-standing
Other characteristics
with HEPA filter, vertical laminar flow
Sound level

65 dB

External width

1,470 mm, 1,770 mm, 2,070 mm
(57.87 in, 69.69 in, 81.5 in)

External depth

790 mm
(31.1 in)

External height

2,100 mm
(82.68 in)

Internal width

1,000 mm, 1,300 mm, 1,600 mm, 1,800 mm
(39.37 in, 51.18 in, 62.99 in, 70.87 in)

Internal depth

600 mm
(23.62 in)

Internal height

690 mm
(27.17 in)

Weight

350 kg, 420 kg, 490 kg, 540 kg
(771.62 lb, 925.94 lb, 1,080.27 lb, 1,190.5 lb)

Description

The Biological Safety Cabinet Class III is designed to provide the highest level of containment when working with hazardous materials involving highly infectious microbiological agents in BSL-4 Cabinet laboratories. These gas-tight enclosures protect the operator, the environment as well as the work in progress. Biological safety cabinet Class III is 100% exhaust type, it ensures that there is no contamination on the samples and no air leakage to laboratory environment. It is the necessary equipment in BSL-4 laboratory. Excellent Filtration System Ambient air is pulled into the cabinet through a pre-filter G4 which can trap larger particles and prolong the main filter service life. Air is passed through the downflow HEPA filter into the work zone as a vertical laminar flow air stream. The uniform non-turbulent air stream protects the samples against cross contamination in work area. The downflow air stream near the work surface splits and exits the chamber through perforations around work zone. Air from work zone passes through the first exhaust HEPA filter below the work surface, before traveling through internal Ducting. Then the filtered air passing through the second exhaust HEPA filter located above the cabinet's main chamber to outside environment.

Catalogs

No catalogs are available for this product.

See all of Antech Group‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.