video corpo

Valve leak tester MF520
for aerosol cansmechanicaldifferential pressure decay

Valve leak tester - MF520 - Ateq - for aerosol cans / mechanical / differential pressure decay
Valve leak tester - MF520 - Ateq - for aerosol cans / mechanical / differential pressure decay
Add to favorites
Compare this product

Characteristics

Applications
for valves, for aerosol cans
Type
differential pressure decay, high-pressure, flow, mass flow, mechanical
Configuration
benchtop
Other characteristics
with flow measurement system, with gas flow sensor, serial line, electronic regulation, high-speed

Description

Product overview
ATEQ's MF520 is a differential micro flow tester combining differential pressure-drop measurement and stable flow measurement to provide fast, repeatable leakage and flow control results for production lines.

Applications
  • Leak detection and flow control: valve seats
  • Gearboxes
  • Hydraulic components
  • Motors
  • Aerosol control
  • Injectors

Features
  • Flow measurement ranges: 2 / 20 / 200 mL/min
  • Selectable measurement units: SI, USA (SAE) and custom units
  • Ambient temperature and atmospheric pressure indications
  • Measurement element fully integrated in a single module
  • Flexible communications: RS232 (printer, PC, memory modules, RC5 remote), RS485 (ATEQ network)
  • Mechanical and electronic pressure regulation across multiple pressure bands

Measurement ranges
Flow Measurement
Range (mL/min) — Accuracy (mL/min) — Max. resolution (mL/min)
2 — +/- (2.5 % Rdg + 0.002) — 0.001
10, 20 or 50 — +/- (2.5 % Rdg + 0.02) — 0.01
200 — +/- (2.5 % Rdg + 0.2) — 0.1

Pressure Measurement
Range — Accuracy — Max. resolution
FS = 20, 75 or 140 mbar — +/- (1.5% Rdg + 0.2 hPa) — 0.1 % FS
FS = 100 or 200 mbar — +/- (1.5% Rdg + 1 hPa) — 0.1 % FS
FS ≤ -850 mbar; 0.3 bar < FS ≤ 2 bar — +/- (1.5% Rdg + 3 hPa) — 0.1 % FS
2 bar < FS ≤ 5 bar — +/- (1.5% Rdg + 7.5 hPa) — 0.1 % FS
5 bar < FS ≤ 10 bar — +/- (1.5% Rdg + 15 hPa) — 0.1 % FS

Technology
The MF520 uses Mass Flow technology that converts the mass of air through a laminar flow element into a leak value. It tolerates large leaks on-line without resetting and does not rely on heating elements for mass measurement, reducing sensitivity to contamination. Measurement is accurate up to 20 bar (300 PSI) with temperature compensation for improved repeatability.

Factsheets
Detailed information, including full features and specifications, is available in the MF520 brochure (English).

Technical specifications
  • Model: MF520
  • Brand: ATEQ
  • Weight: Approximately 7 kg
  • Dimensions (W×H×D): 250 × 150 × 360 mm
  • External electrical supply: 24 VDC / 1.6 A or 110–240 VAC
  • Operating temperature: +10°C to +45°C
  • Storage temperature: 0°C to +60°C
  • Interface: Navigation keys, 4-line LCD display, result indicator lights
  • Air supply: Clean, dry air (air quality per ISO 8573-1)
  • Options and I/O: 7 inputs / 5 outputs; 2 pneumatic outputs for sealing connectors; 6 × 24 V programmable outputs; electronic regulator; dual pressure; high-speed valve; 2 analog outputs (current or voltage); Fieldbus
  • Flow and pressure measurement: ranges and accuracies as listed above

Catalogs

No catalogs are available for this product.

See all of Ateq‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.